ANNA MARIA MERMAID

ANNA MARIA MERMAID is a 2006 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in March 2026, along with 40 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 11 March 2026.

Built
2006
Last inspected
11 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 March 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP4696
864810
Flag
UNITED STATES
Maury page id
psix-864810

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

11 March 2026 Drydock Exam · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8312893
7 January 2025 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8059670
3 April 2024 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7889423
6 March 2024 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7874967
29 June 2023 Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7714046
15 March 2023 Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7646021
18 March 2022 Internal Structural Exam · Deficiency Check · Examination of Repairs · Hull Examination · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7403284
23 March 2021 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7154175
1 May 2020 Annual Inspection · Drydock Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6937130
19 February 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6625429
22 May 2018 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6403378
12 February 2018 DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6340293
22 May 2017 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6141959
18 May 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5879265
27 April 2016 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5863836

Deficiency record · 40

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 March 2026 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry—(1) Six hand red flare distress signals and (2) Six hand orange smoke distress signals. MI observed only 3 red flares on board vessel. Replace to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2026
Resolved 23 March 2026
Resolution: Received photos showing satisfactory flares.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 March 2026 Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. MI observed 02 missing fire buckets. Replace to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2026
Resolved 23 March 2026
Resolution: Received photo showing satisfactory fire buckets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 March 2026 Resolved
Certification or licensing by a state or local jurisdiction as a fire extinguisher servicing agency will be accepted by the Coast Guard as meeting the personnel certification requirements of NFPA 10 for annual maintenance and recharging of extinguishers. MI observed 02 fire extinguishers with expired service tags/records. Replace/Repair to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2026
Resolved 6 April 2026
Resolution: Received proof of fire extinguisher servicing.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 March 2026 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. MI observed 02 missing portable light. Replace to the satisfaction of the MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2026
Resolved 23 March 2026
Resolution: Received photo showing satisfactory protable lights.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 11 March 2026 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. MI observed emergency instructions missing from operating station. Replace to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2026
Resolved 23 March 2026
Resolution: Received photos showing satisfactory emergency instructions.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 March 2026 Resolved
By March 15 of the year following the collection of the data in paragraph (a) of this section, marine employers must submit the data on the form titled U.S. Department of Transportation Drug and Alcohol Testing MIS Data Collection Form. MI observed missing MIS report. Replace to the satisfaction of the attending MI. 46 CFR 16.500 (b) (1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2026
Resolved 23 March 2026
Resolution: Received satisfactory MIS Report.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 March 2026 Resolved
The EPIRB test shall be logged or otherwise documented, as applicable. MI observed missing EPRIB entry logs. Provide evidence on documentation to satisfaction of MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2026
Resolved 23 April 2026
Resolution: Operator provided proof of new EPRIB capable of being tested.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 March 2026 Resolved
Limited Coastwise (Not more than 20 miles from a harbor of safe refuge). Within three miles of shore. W/float free 406 MHz EPIRB. MI observed fault during EPIRB test. Vessel is restricted to Lakes, Bays, and Sound route only until functional EPIRB is installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2026
Resolved 23 April 2026
Resolution: Operator provided proof of satisfactory installation of new EPIRB.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 January 2025 Resolved
46CFR176.500(b)(1) 701 c A vessel must undergo an inspection for certification as specified in 176.404 and annual inspection as specified in paragraph (b)(1) of this section. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel was due for an annual COI inspection on 15 March 2024. Vessel shall not operate with passengers until annual COI inspection has been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 January 2025
Resolved 11 March 2026
Resolution: Vessel underwent COI inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 January 2025 Resolved
46CFR176.600(c)(1) 701 c The owner or managing operator shall make a vessel available for drydock examinations and internal structural examinations. A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel was due for its hull exam on 31 March 2024. Vessel shall not operate with passengers until annual COI inspection has been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 January 2025
Resolved 11 March 2026
Resolution: Vessel underwent drydock exam.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 April 2024 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel was due for drydock examination on 31MAR24 and has yet to receive a drydock exam. 46CFR176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2026
Resolution: Vessel underwent drydock exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 June 2023 Resolved
A vessel of at least 7.9 meters (26 feet) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment, except that space forward of the collision bulkhead. MI was unable to witness operation of bilge pumps. 46 CFR 182.510(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2023
Resolved 7 August 2023
Resolution: MIs witnessed satisfactory operational test of bilge system and high water alarms.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 June 2023 Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (2.5 gallon) buckets with attached lanyard. The words "FIRE BUCKET" must be stenciled in contrasting color on each bucket. Vessel did not have any fire buckets on board. 46 CFR 181.610
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2023
Resolved 7 August 2023
Resolution: Vessel had on-board three fire buckets.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 June 2023 Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date. EPIRB registration was not up-to-date to reflect the current owner. 47 CFR 80.1061(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2023
Resolved 27 October 2023
Resolution: Vessel representative sent over proper EPIRB Registration.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 29 June 2023 Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. All life jackets on-board had the name of the previous vessel. 46 CFR 185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2023
Resolved 7 August 2023
Resolution: New vessel name was on life jackets.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 June 2023 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel did not have a log where man overboard, abandon ship, fire drills, and EPIRB tests were logged. 46 CFR 185.520(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2023
Resolved 25 October 2023
Resolution: Vessel sent over satisfactory evidence of MOB and Fire Drills being logged in log book.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 29 June 2023 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel had emergency instructions for the previous vessel. 46 CFR 185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2023
Resolved 7 August 2023
Resolution: Vessel had emergency instructions on board.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 29 June 2023 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel had an FCC Station License, but it was issued to previous vessel. 46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2023
Resolved 7 March 2024
Resolution: Vessel has changed ownership. Will address this at inspection with new O/O on 21MAR24.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 March 2023 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. The owner repowered the vessel from a 200 HP Evinrude to a 250 HP Yamaha in 2018 without notifying the CG. The vessel's stability letter is based on a deadweight survey. A change in the lightship as per the stability letter requires a new stability test. The owner shall submit lightship characteristics to MSC for the repower. 46 CFR 185.100
Action required: 705 - Other - as specified
Due 24 April 2023
Resolved 12 April 2023
Resolution: The operator submitted the lightship change to MSC. A MSC letter was issued to the owner on April 10, 2023 with the new engine information. A new stability test is not required.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 March 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The port hull was found with an unapproved repair located on the hull next to the port aft flush deck screw down. The repair was made with epoxy putty and does not match the approved FRP layup. The repair appears watertight and is located approximately 2" below the main deck. The repair measures approximately 4" in length and 3" in height. Permanent repairs shall be made prior to the next credit dry dock. 46 CFR 176.700
Action required: 705 - Other - as specified
Due 31 March 2024
Resolved 11 March 2026
Resolution: Verified permanent repair.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 March 2023 Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel was due for COI inspection on 23FEB23 and has yet to receive a COI inspection. Vessel shall not operate with passengers until new COI has been issued. 46 CFR 176.100
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2023
Resolved 20 March 2023
Resolution: A COI renewal was completed on March 20, 2023.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 March 2023 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). The vessel is arranged with a submersible electric bilge pump and a hand portable pump. The hand portable pump was not operational when tested by the owner. 46 CFR 182.520(a)
Action required: 705 - Other - as specified
Due 15 March 2023
Resolved 20 March 2023
Resolution: The owner purchased a new portable hand pump and operationally tested it.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 March 2023 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The owner purchased a new VHF radio and it was found installed at the operating console. The radio electrical conductors were missing enclosures or incorrectly installed enclosures. The VHF radio was not inspected by a FCC technician and a valid FCC safety radio certificate was not onboard. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2023
Resolved 12 April 2023
Resolution: The new VHF radio has the MMSI number programmed in. The radio was verified by a FCC technician and a new FCC safety certificate was issued to the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 15 March 2023 Resolved
Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must be watertight and have no obstruction to overboard drainage. The aft freeing ports used for draining the main deck were found blocked by bundled electrical conductors on the starboard side and an anchor on the port side. Clear the freeing ports to permit free drainage aft. Remove the water found in the port forward hull compartment. Rectify prior to issuance of the COI. 46 CFR 178.410
Action required: 705 - Other - as specified
Due 15 March 2023
Resolved 20 March 2023
Resolution: The conductors were installed above the drainage ports to allow water to drain as originally built. All water was removed from the hull and the hull was dried out. Flush deck hatches were replaced like and in kind.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: Provide services necessary for safety under normal and emergency conditions; Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Minimize accidental personnel contact with energized parts; and Prevent electrical ignition of flammable vapors. The DC electrical system was found with multiple dead end live positive conductors connected to the power source which presents a fire hazard and shock hazard to personnel. The positive conductors for the branch electrical components were all found attached together using multiple ring terminals connected by a rivet which presents a resistance and heat hazard. The negative conductors for the entire DC system were found connected to a screw and free floating behind the bulkhead. The positive and negative conductors for the DC system were not found connected to the terminal strips attached at the bulkhead behind the operating station. Install the DC electrical system as per original approved electrical drawings. Rectify prior to issuance of the COI. 46 CFR 183.200
Action required: 705 - Other - as specified
Due 15 March 2023
Resolved 20 March 2023
Resolution: All dead end conductors were removed and the DC electrical matches the approved drawings.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2023 Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. A 25 amp blade fuse was found installed as the primary branch overcurrent protection next to the batteries which is not in accordance with the original approved electrical plans. The batteries were found wired in parallel and the CCA delivery is 1800 amps. The AIC for the 25 amp blade fuse is less than the CCA output of the batteries. Blade fuses are not authorized on commercial passenger vessels. Authorized UL listed cartridge fuses are RK-5, K-5, CC, or T. Provide a UL listed cartridge fuse to protect the 12 AWG conductor used to provide power to the DC electrical circuit. Rectify prior to issuance of the COI. 46 CFR 183.380(l)
Action required: 705 - Other - as specified
Due 15 March 2023
Resolved 20 March 2023
Resolution: The blade fuse was removed and a 25 amp UL listed cartridge RK-5 fuse was installed as primary branch protection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 March 2023 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. The master did not have a deckhand in attendance for the COI in order to complete a man overboard recovery drill. Rectify prior to issuance of the COI. 46 CFR 176.808(g)
Action required: 705 - Other - as specified
Due 15 March 2023
Resolved 20 March 2023
Resolution: The deckhand was present for the inspection on this date.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 15 March 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline. Prove operation of the high water alarm during the next MI attendance after the DC electrical system is repaired. 46 CFR 182.530
Action required: 705 - Other - as specified
Due 15 March 2023
Resolved 20 March 2023
Resolution: The high water alarm was operationally tested on this date and found to be ready for service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 May 2020 Resolved
Port catamaran portable bilge pump was inoperable. Each catamaran on a vessel must have an operable bilge pump. 46CFR182.520(j)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2020
Resolved 4 May 2020
Resolution: Vessel owner replaced with new bilge pump.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 May 2020 Resolved
Vessel did not have an approved first aid kit onbaord. 46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2020
Resolved 4 May 2020
Resolution: Vessel owner provided approved first aid kit.
Construction/Loadline › Hull › Bottom Plating
Issued 22 May 2018 Resolved
Submit repair proposal for damage to hull STBD side in front of middle stabilizer. Complete prior to dry dock credit. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 29 May 2018
Construction/Loadline › Penetrations › Valve Flange
Issued 22 May 2018 Resolved
Thru-hull valve cannot be reached to exercise or demonstrate proper closing. Submit a proposal that makes the valves closure reachable and operable in accordance with good marine practice. 46 CFR 179.350
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 May 2018
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 12 February 2018 Resolved
Provide proof of compliance with chemical testing requirements IAW 46 CFR 16.260
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2018
Communications › Alarms/Indicators › High Water Alarm
Issued 22 May 2017 Resolved
Prove operation of stbd side bilge high level alarm. 46 CFR 182.530
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 23 May 2017
Resolution: Verified proper operation of high level alarm.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 22 May 2017 Resolved
Service B-1 portable fire extinguisher; provide srvicing report. 46 CFR 176.810
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 23 May 2017
Resolution: Verified B-1 portable fire extinguisher serviced.
Communications › Radio Communications › VHF Radiotelephone
Issued 22 May 2017 Resolved
Program radio with MMSI number and provide GPS input. 46 CFR 184.502
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 25 May 2017
Resolution: Verified radio properly programmed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 May 2017 Resolved
Replace expired waterlight battery. 46 CFR 180.70
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 23 May 2017
Resolution: Operator replaced expired battery.
Lifesaving › Lifebuoys › Serviceable
Issued 22 May 2017 Resolved
Provide retro reflective tape on ring bouy. 46 CFR 180.70
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 23 May 2017
Resolution: Operator replaced retro reflective tape on ring buoy.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 22 May 2017 Resolved
Provide two portable flashlights on board. 46 CFR 183.430
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 23 May 2017
Resolution: Operator provided two portable lights.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 May 2017 Resolved
Replace missing aspirin in first aid kit. 46 CFR 184.710
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 23 May 2017
Resolution: Operator replaced aspirin.