MAURY USCG vessel records Sign in
← All vessels

JAG LAXMI

JAG LAXMI is a 1998 tank ship. The Coast Guard has recorded 35 inspections since 2000, most recently in June 2018, along with 12 deficiencies and 11 operational controls.

Records from 2000 to 2018. Most recent: operational control imposed, 18 June 2018.

Built
1998
Last inspected
17 June 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9173642 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
INDIA
—
Maury page id
psix-8650

Inspections, by type

…with no type recorded16
Years with a record 11 calendar years (2000–2018)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it58374 - Convention (Subpart B), Gross Ton
30037 - Convention (Subpart B), Net Ton
122175 - Displacement, Ton
105051 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 35

17 June 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6446960
20 July 2015 Ballast Water Examination · Deficiency Check · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5190638
8 January 2011 COE-Dockside
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3919733
23 December 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3919812
22 December 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3914810
2 November 2010 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3883404
23 September 2010 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3855533
5 September 2010 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3835184
15 February 2010 COE-Administrative
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3680123
22 January 2010 MARPOL Annex V Examination · COE-Dockside · COC-TVE Annual · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3665607
2 March 2009 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3426516
2 March 2009 COE-Dockside
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3426665
10 June 2008 MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · COC-TVE Renew · MARPOL Annex V Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3231938
13 April 2007 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2895970
12 April 2007 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2896701
15 May 2006 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2634960
27 March 2006 ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · COC-TVE Renew · MARPOL Annex V Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2610078
6 February 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2580027
12 January 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2586365
11 January 2006 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2578685
13 July 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2425530
2 July 2005 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2408959
27 June 2005 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2404880
2 June 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2392729
22 April 2005 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2340536
22 April 2005 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2340785
14 April 2005 COC-TVE Annual · ISPS III Exam
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2333776
26 February 2005 PII Safety Exam · Random ISPS/MTSA/PSC · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2299673
23 November 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2247076
15 October 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2221538
8 October 2004 Random ISPS/MTSA/PSC
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2216823
15 May 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2070180
2 April 2004 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2037586
24 October 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 283053
24 October 2000 Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1055734

Deficiency record · 12

Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 20 July 2015 Resolved
2535-Development of Plans for Shipboard ops-Every company should develop, implement, and maintain a Safety Management System. PSCO discovered objective evidence, supported by the above 7 deficiencies, that the company has failed to implement an effective SMS. Recommend external audit. 74SOLAS(2009 cons.) IX/3.1; ISM CODE 1.4
Action required: 705 - Other - as specified
Due 20 August 2015
Resolved 14 August 2015
Resolution: External audit conducted by RO on 29 July 2015. Documentation of audit provided on 14 Aug to attending examiner; deficiency cleared.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Electric Bonding
Issued 20 July 2015 Resolved
1835-Cargo Vent System-Vapor collection piping must me electrically bonded to the hull and must be eletrically continous. Bonding cables are broken or missing in several locations on deck. 46CFR 39.2001(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2015
Resolved 20 July 2015
Resolution: Vessel installed bonding straps in cargo transfer piping were needed on deck to the satisfaction of PSCO.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 20 July 2015 Resolved
1835-Cargo Vent System- Venting arrangements shall be so designed and operated as to ensure that vacuum in cargo tanks does not exceed design standards. Vacuum side of PV Valve on 1P flame screen is dirty and will not allow passage of air. 74SOLAS (2001cons)II-2/59.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2015
Resolved 20 July 2015
Resolution: Vessel cleaned flame screen allowing the PV valve to properly operate.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 20 July 2015 Resolved
1830-Cargo Transfer-Each transfer pipe system must not leak under static liquid pressure at least 1.5 times the maximum working pressure. Vacuum line on #3 cargo oil pump is visibly leaking. 33 CFR 156.170 (c)(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2015
Resolved 20 July 2015
Resolution: Vessel repaired and pressure tested the pipe to the satisfaction of the PSCO
Electrical › Electrical Distribution System (service) › Cable
Issued 20 July 2015 Resolved
1870-Special requirements- Where cables which are installed in hazardous areas introduce the risk of fire or explosion, special precautions against such risks shall be taken. Cable support for electrical control on the mast riser are severely wasted and broken away. 74SOLAS(2001cons) II-1/45.5.4
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 August 2015
Resolved 14 August 2015
Resolution: Repairs to cable supports near mast riser verified by attending examiner.
Engineering › Compressed Air System (control) › Piping
Issued 20 July 2015 Resolved
1499- Other(Prop. & Machinery Auxiliary) - Machinery and associated piping systems shall be of a design and construction adequate for the service for which it is intended. Ship's service air line in vicinity of 6S is severely wasted and holed. 74SOLAS(2001cons)II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 August 2015
Resolved 14 August 2015
Resolution: Ship service air line in vicinity of 6S renewed.
Deck/Cargo › Inert Gas System › Venting System
Issued 20 July 2015 Resolved
1850- Fire protection cargo deck area- Instrumentation shall be fitted for continuously indicating time oxygen content of the inert gas. Ships #2 Oxygen analyzer is not operational. 74SOLAS(2001cons) II-2/62.16.1.2
Action required: 15 - Rectify deficiencies by next port
Due 20 August 2015
Resolved 14 August 2015
Resolution: Defective oxygen analyzer was replaced and proper operation demonstrated to attending examiner.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 20 July 2015 Resolved
1840- Instrumentation-A cargo tank must be equipped with a closed gauging device. Gauging system for port slop tank is not operational. 46CFR 39.2003(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2015
Resolved 14 August 2015
Resolution: Ship''s crew replaced defective gauging device at cargo tank and demonstrated proper operation.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 10 June 2008 Resolved
Make repairs to water supply line to the deck water seal. complete repairs prior to discharge of cargo to the satisfaction of the attending CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2008
Resolution: Witnessed feed water line repaired with liking kind.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 March 2006 Resolved
Walkway gratings for foam monitors and manifolds are wasted and have holes through them in multiple locations on deck. Provide temporary means for covering holes and provide permanent replacement of all wasted gratings prior to next U.S. port, but no later than 11APR2006 to the satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Due 15 May 2006
Resolved 15 May 2006
Resolution: Received DNV class report attesting to satisfactory replacement of deck gratings.
Navigation › Piloting/Steering › Gyro Compass
Issued 2 July 2005 Resolved
Vessel was issued a letter of deviation for an inoperable gyro compass (33 CFR 164.35(d).) This is based on the understanding that the equipment will be operable prior to departing the port of Corpus Christi.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2005
Resolution: Received tech report via fax confirming that the repairs have been made and the equipment is operable.
Deck/Cargo › Inert Gas System › Gas Regulating Valve
Issued 14 April 2005 Resolved
O2 analyzer for IG system is inoperable. No COW ops in US waters and regular O2 readings of cargo tanks taken, until analyzer replaced and satisfactory operation verified by class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 April 2005
Resolution: Cleared to the satisfaction of class and was verified. Two separate oxygen monitors were installed.

Ownership record