MAURY USCG vessel records Sign in
← All vessels

BOBCAT

BOBCAT is a 2008 offshore supply vessel. The Coast Guard has recorded 23 inspections since 2007, most recently in March 2026, along with 9 deficiencies.

Records from 2007 to 2026. Most recent: inspection, 31 March 2026.

Built
2008
Last inspected
31 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9555773 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH 3238
865250
Flag
UNITED STATES
367605680
Maury page id
psix-865250

Inspections, by type

Years with a record 16 calendar years (2007–2026)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)130.5 ft × 36.0 ft × 12.0 ft
Registered tonnagegross 88 / net 60
ITC dimensions (L × B × D)130.5 ft × 36.0 ft × 12.0 ft
ITC tonnagegross 447 / net 134
BuilderMASTER BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 January 2026 · expires 28 February 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it88 - Regulatory (Subpart C or D), Gross Ton
447 - Convention (Subpart B), Gross Ton
576 - Dead Weight, Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
134 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH3238MMSI 367605680 · active · compulsorily equipped · granted 29 November 2023, expires 12 February 2034
WDE4348MMSI 367351810 · cancelled · compulsorily equipped · granted 25 April 2008, cancelled 27 January 2014 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 23

31 March 2026 Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8323425
5 March 2026 Cargo Tank Internal · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8308751
10 July 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8180837
23 May 2024 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7923092
17 April 2023 Drydock Exam · COI Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7668528
6 July 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7498927
25 February 2021 Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7145997
21 August 2020 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7038978
15 August 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6784607
22 May 2018 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6420281
16 May 2018 Cargo Tank Internal · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6417778
28 June 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6189898
15 April 2016 Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5854448
11 January 2016 Administrative Inspection · Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5794885
17 July 2015 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5209023
9 May 2012 MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4306910
23 July 2009 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3543762
27 April 2009 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3462233
22 April 2009 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3458137
11 July 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3264626
8 May 2008 Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3200770
29 April 2008 Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3194831
15 June 2007 Plan Review (Other than "T") · Cargo Tank Internal · MTSA Verification · Initial Certification · Hull Examination · Drydock Exam · Welding Related Inspections Qualification Testing · Construction Oversight · Ballast Water Examination · Internal Structural Exam · Initial Construction-Excluding Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3196679

Deficiency record · 9

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2023 Resolved
electrical equipment on a vessel must be designed, installed, and maintained to protect crew members and vessel from electrical hazards caused by originating electrical equipment. Port generator was leaking water. Conduct maintenance and provide tech report. 46 CFR 129.200(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2023
Resolved 25 April 2023
Resolution: Received tech report for repaired water leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2023 Resolved
When alterations or repairs of machinery becomes necessary, work shall be done in accordance with regulations. Water pump tank was not permanently affixed to deck. Make proper weld repairs. 46 CFR 128.110(a) 46 CFR 50.05-10(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2023
Resolved 25 April 2023
Resolution: Received pictures for welded brackets for water tank pump.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 February 2021 Resolved
Vessel piping shall be maintained in good condition. Potable water pipe in engine room had small pinhole leak
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2021
Resolved 26 February 2021
Resolution: Clad-welded pinhole.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 26 February 2021 Resolved
A rudder-angle indicator must be installed at the steering-control station at the pilot house. The starboard rudder angle indicator at the pilothouse on non-followup mode steering was not responding.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2021
Resolved 26 February 2021
Resolution: Sent video of RAI operating properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 February 2021 Resolved
Where pressure indicating gages are used on pressure vessels the upper range of the gage shall be between 1.2 times and 2 times the relief device set pressure. The gages on the pressure vessels had an upper range of 200 with a relief valve set pressure of 175.
Action required: 10 - Deficiency Rectified
Due 26 February 2021
Resolved 26 February 2021
Resolution: Relief valves were changed to 150 psi.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 February 2021 Resolved
Vessel shall be in a safe and seaworthy condition including watertight integrity. Main engine room escape hatch had light and air coming through it.
Action required: 10 - Deficiency Rectified
Due 26 February 2021
Resolved 26 February 2021
Resolution: Escape was adjusted to properly seal. No visible light or air coming through.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 August 2020 Resolved
YOUR VSL MUST UNDERGO AN ANNUAL INSPECTION W/I 3 MONTHS BEFORE OR AFTER EACH ANNIVERSARY DATE; VSL HAS NOT COMPLETED ANNUAL INSPECTION WITHIN REQUIRED 3 MONTH ALLOWED TIME WINDOW AFTER ANNIVERSARY DATE OF 22MAY20. M/V BOBCAT MUST COMPLETE ANNUAL USCG INSPECTION PRIOR TO MOVEMENT.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 August 2020
Resolved 18 September 2020
Resolution: Conducted periodic inspection.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 17 July 2015 Resolved
Provide power to SSB on emergency power
Due 24 July 2015
Resolved 17 July 2015
Resolution: Deficiency corrected during inspection.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 17 July 2015 Resolved
Replace wasted flexible hose on jacket water piping on starboard generator.
Due 24 July 2015
Resolved 17 July 2015
Resolution: Corrected during inspection.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.