01 - Certificates & Documentation › 011 - Ships Certificates › International Air Pollution Certificate (IAPP)
Issued 8 April 2025
Resolved
IAPP CERT shall be issued after a renewal survey in accordance with the provision of regulation 5 of this annex.
Vessel did not have access to their tech file and EIAPP for all engines listed on current IAPP and missing record book. Vessel shall provide copies and/or proof prior to getting IAPP endorsed.
CITE: MARPOL ED. 2022, ANNEX IV, REG 6.1.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 7 May 2025
Resolution: Received, satisfactory.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 8 April 2025
Resolved
Oil Record Book Part 1 shall be completed on each occasion, on a tank-to-tank basis, whenever any of the machinery space operations takes place.
Crew had improper record keeping of waste oil and ballast water to reception facilities. Also not logging collection of oily water and ballast water in tanks. Company shall provide proper training and provide proof of completed training.
CITE: MARPOL ED. 2022, ANNEX I, REG 17.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 7 May 2025
Resolution: Received company training proof
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 April 2025
Resolved
Maintain ballast water management plan that has been developed specifically for the vessel.
Vessel shall retain a vessel specific ballast water management system plan and implement it, to include record keeping.
CITE: 33 CFR 151.2050(g)
33 CFR 151.2070(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 7 May 2025
Resolution: Received updated ballast water management plan
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 8 April 2025
Resolved
Each self-contained breathing apparatus shall have a minimum 30 minute air supply.
Vessel shall maintain air bottles to be full with fire suits.
CITE: 46 CFR 96.35-5(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 May 2025
Resolved 8 April 2025
Resolution: Filled bottles same day.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2025
Resolved
If a lifebuoy is intended to operate the quick release arrangement provided for the self-activated smoke signals/ lights, it shall have a mass sufficient to operate the quick release arrangement, but not less than 4kg (8 pounds 13 ounces). The lifebuoys in this arrangement were regular deck buoys and not of adequate weight.
Vessel shall install proper bridge buoys.
CITE: 46 CFR 199.150-4(e)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 May 2025
Resolved 8 April 2025
Resolution: Installed proper life rings.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 7 February 2024
Resolved
The Oil record book part 1, shall be completed on each occasion if appropriate whenever collecting and disposal of oilresidues. Crew was not recording weekly soundings
Action required: 10 - Deficiency Rectified
Due 7 February 2024
Resolved 7 February 2024
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 7 February 2024
Resolved
Each discharge operation shall be recorded in the garbage record book. Crew was not logging plastic discharge.
Action required: 10 - Deficiency Rectified
Due 7 February 2024
Resolved 7 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 February 2024
Resolved
Each vessel must minimize hazards (fire). Broken bracket on STBD MDE high pressure fuel line.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 7 February 2024
Resolved 7 February 2024
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 7 February 2024
Resolved
Each Vessel must comply with 47CFR part 80. Radiotelophone log was not being checked and signed by master.
Action required: 10 - Deficiency Rectified
Due 7 February 2024
Resolved 7 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 7 February 2024
Resolved
Each liferaft must be arranged for float free launching. Vessel float free arrangement was unsatisfactory.
Action required: 10 - Deficiency Rectified
Due 7 February 2024
Resolved 7 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 11 April 2023
Resolved
Each liferaft must be arranged for float-free launching; liferafts were not properly attached to weak link to provide float free arrangement.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 11 April 2023
Resolution: Installation corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 August 2022
Resolved
Each class 1 door on a vessel in ocean service must be cabals of holding head of water. Door to emergency escape hatch on starboard side needs gasket replaced. Starboard emergency escape hatch needs gasket replaced and readjustment. Battery stuffing tube on port side to be replaced to ensure watertight integrity.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2022
Resolution: Veriifed watertight seal was corrected via light and air to the satisfaction fo the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 3 August 2022
Resolved
Vessel must have line-throwing appliance approved under 160.040. Incorrect line-throwing appliance on board and associated equipment. Must have impulse style.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 August 2022
Resolution: Inspected 4 impulse line-throwing devices and requried line.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 3 August 2022
Resolved
Every ship of 400 GT and above shall be provided with an Oil Record Book Part 1 and shall be completed on each occasion when machinery space operations occurs on vessel. Vessel did not have Oil Record book.
Action required: 702 - Prior to embarking on international voyage
Resolved 9 February 2024
Resolution: ORB was being maintained during topside inspection.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 3 August 2022
Resolved
Vessels 400 GT or greater should maintain Garbage Record Book. The Garbage Record Book had incorrect entries, corrections with whiteout, and lack of signature on each page.
Action required: 10 - Deficiency Rectified
Resolved 5 August 2022
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 August 2022
Resolved
Detectors must be responsive to heat, smoke, or products of combustion. Smoke detector in #4 crew room inoperable, to be repaired/ replaced.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2022
Resolution: Tested #4 berthing smoke detector sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 August 2022
Resolved
Connection on all firefighting extinguishing equipment to be checked to ensure it’s in operating condition. Canister in CO2 room needs but tightened to hose.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2022
Resolution: The fixed firefighting sytem was inspected. The hose was tightned.
11 - Life Saving Appliances › N/A - No Subsystem › Fast Rescue Boats
Issued 3 August 2022
Resolved
46 CFR 160.156-7: Exterior of each rescue boat must be marked with Type II retro reflective material. Type II retro on rescue boat excessively worn. Starboard aft ring buoy has lettering over Type II retro, to be repaired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 August 2022
Resolution: New SOLAS tape was placed on the Rescue Boat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 August 2022
Resolved
Powerdriven vessels underway should have sidelights. 01 starboard nav. light inoperable; replaced on spot
Action required: 10 - Deficiency Rectified
Resolved 5 August 2022
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 3 August 2022
Resolved
Lighting for survival craft launching stations required. Starboard life raft emergency light inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2022
Resolution: New Bulb was installed and tested.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 2 August 2022
Resolved
Every vessel over 400 GT shall have the bunker delivery note kept onboard the vessel NLT three years and the bunker sample shall be kept onboard until the fuel oil is substantially consumed, but NLT 12 months after delivery. Vessel did not have bunker notes for the previous 3 years nor fuel samples for the past 12 months. MARPOL VI/18.5 & MARPOL VI/18.8.1
Action required: 702 - Prior to embarking on international voyage
Resolved 9 February 2024
Resolution: Bunker delivery receipts were avaiable during the inspection.
01 - Certificates & Documentation › 012 - Crew Certificates › Cert for personnel on survival craft & rescue boat
Issued 6 July 2021
Resolved
Vessel shall carry the personnel requried by the COI. The vessel did not ahve the required lifeboatman (2) and deckhands (2) as the Captain did not the the lifeboatman and one deckhand had an expired TWIC w/o credentials.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 July 2021
Resolution: Vessel had crew change for Master and one deckhand. New crew had proper credentials and TWIC.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 6 July 2021
Resolved
Rescue boat shall be in good working order and ready for immediate use. Davit system was not able to recover rescue boat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 July 2021
Resolution: Vessel had third party come out to make adjustement to davit. See attached work order.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 6 July 2021
Resolved
Vessel shall preforme quartly inspectrion and maintaince of rescue boat with MOB. Vessel shall preforme MOB with Rescue boat or rescue platform. Vessel did not preform MOB with rescue boat.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2021
Resolved 2 August 2021
Resolution: Vessel rep sent pictures of the MOB being preformed. Vessel rep stated that the vessel had been practicing regulary.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 July 2021
Resolved
Lifefloats shall be outfitted IAW 46CFR106.073. Lifefloats did not have the required reflective tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2021
Resolved 2 August 2021
Resolution: Vessel rep submitted picture of completed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 July 2021
Resolved
Vessel shall maintain up to date charts. Vessel had not updated charts since printing on May 10, 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2021
Resolved 2 August 2021
Resolution: Vessel rep sent picture of chart updates.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 6 July 2021
Resolved
Vessel shall have an opperatonal rudder angle indicator. Vessel's angle indicator was not operational during non-followup for Stbd rudder.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2021
Resolved 2 August 2021
Resolution: vessel sent picture of workorder regarding the rudder angle indicator.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 9 May 2018
Resolved
A rudder angle indicator independent of the control of the main steering gear must be installed at the steering control station in the pilot house. Rudder angle indicators at forward steering station in pilot house indicate a difference of 5 degrees from each other when operationally tested. Rudder angle indicators at aft steering station in pilot house indicate a difference of 10 degrees from each other when operationally tested.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2018
Resolved 24 July 2018
Resolution: Technician report received attesting to the repair.
Operations/Management › Pollution › Control of Garbage
Issued 9 May 2018
Resolved
All ships of 400 gross tonnage and above and every ship which is certified to carry 15 persons or more engaged in voyages to ports and offshore terminals under the jurisdiction of another Party to the Convention shall provide a Garbage Record Book to record all disposal and incineration operations. A new form of the Garbage Record Book (GRB) has been included in appendix II to MARPOL Annex V. Each ship must comply with Annex I, II or V of MARPOL 73/78 unless otherwise indicated. The vessel does not have onboard the new form of Garbage Record Book to engage in voyages to ports and offshore terminals under the jurisdiction of another Party to the Convention.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2018
Resolved 18 July 2018
Resolution: New garbage record book onboard and in use.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 9 May 2018
Resolved
Each ship that is operated under the authority of the United States and is certificated for ocean service or coastwise service beyond 3 nautical miles from land shall maintain an oil record book in accordance with 33 CFR 151.09(a). Entries shall be made in the oil record book on each occasion when disposal of bilge water or oil residue that has accumulated in the machinery spaces takes place. The oil record book is missing all entries for removing bilge water or oil residue from machinery spaces since the vessel began operating under its certificate of inspection. The operator admitted to offloading bilge water and oil residue from the machinery space to their own facility which is not an approved reception facility to dispose oily waste or contaminated bilge water from vessel machinery spaces. One receipt was available for offloading oil, oily waste, or contaminated bilge water from vessel machinery spaces. The receipt was issued by PENCO in May 2017.
Condition: Improper/Lack of Maintenance
Action required: 702 - Prior to embarking on international voyage
Due 9 June 2018
Resolved 7 September 2018
Resolution: Examined ORB and found SAT.
Engineering › Bilge Water Management System › Interface Detector
Issued 9 May 2018
Resolved
No person may operate an oceangoing ship of less than 400 gross tons on an international voyage unless it is fitted with an approved 15 parts per million oily water separating equipment for processing oily mixtures from bilges. Equipment installed after 2004 must meet current standards in 46 CFR 162.050. Oil content meter found installed onboard without a calibration certificate.
Condition: Improper/Lack of Maintenance
Action required: 702 - Prior to embarking on international voyage
Due 9 June 2018
Resolved 10 September 2018
Resolution: Witnessed satisfactory operational test.
Documentation › Certificates/Documents › IOPP Certificate
Issued 9 May 2018
Resolved
Annual IOPP surveys for inspected ships are to determine that the oily water separating equipment and associated pumps and piping systems remain satisfactory for the service intended, and that no unauthorized alterations have been made. A licensed chief engineer was not present for the annual inspection. The crew onboard was not familiar with the OWS operating procedures. A piping diagram with the original approved oily water separating equipment and associated pumps and piping systems was not onboard. The marine inspector is unable to determine if unauthorized modifications have been made without the original approved diagram to review. Make oily water separating equipment available for inspection by a competent licensed engineer officer per the COI.
Condition: Improper/Lack of Maintenance
Action required: 702 - Prior to embarking on international voyage
Due 9 June 2018
Resolved 10 September 2018
Resolution: Cleared all outstanding items required to issue a IOPP. Issued IOPP.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 11 May 2017
Resolved
Provide an approved D/C electrical diagram within 30 days as per 46 CFR 90.25-1.
Condition: Improper/Lack of Maintenance
Due 12 June 2017
Resolved 2 March 2018
Resolution: [name withheld] provided DC drawing.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 11 May 2017
Resolved
Prove the proper installation of the A/C electrical system within 30 days as per 46 CFR 90.25-1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 23 January 2018
Resolution: Recieved AC system drawig from vessel rep.
Navigation › Piloting/Steering › Marine Charts
Issued 11 May 2017
Resolved
Provide updated navigational charts for all areas of operations within 7 day as per 46 CFR 97.05-5.
Condition: Improper/Lack of Maintenance
Due 18 May 2017
Resolved 15 May 2017
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 11 May 2017
Resolved
Prior to departure and at all times necessary the master shall ensure that the vessel complies with all applicable stability requirements and log the vessel’s draft, trim, and stability in the unofficial logbook as per 46 CFR 97.15-7.
Due 11 May 2017
Resolved 11 May 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 May 2017
Resolved
No means shall be provided to lock doors for the required means of escape. Prove no means of escape can be locked to prevent escape within 30 days as per 46 CFR 92.10-20.
Due 12 June 2017
Resolved 24 May 2017
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 11 May 2017
Resolved
Prove the proper operation of the lube oil, over speed, and high cooling water temp alarm and shutdowns within 30 days as per 46 CFR 61.20-3.
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 17 August 2017
Resolution: Proper tests conducted and witnessed.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 12 August 2016
Resolved
Provide embarkation ladder for both embarkation stations on 2nd deck as required by 74 SOLAS 2014, Chapter III, Regulation 11.7
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2016
Resolved 22 August 2016
Resolution: Verified vessel has two SOLAS approved embarkation ladders (one for each liferaft launching station).
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 11 August 2016
Resolved
Replace all valves and check valves constructed of bronze or other non-ferrous materials which are installed in fuel oil, lube oil, dirty oil, and oily water systems at next dry docking.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 January 2017
Resolved 11 March 2017
Resolution: All bronze valves replaced with stainless.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 11 August 2016
Resolved
provide proper over-current protection for the emergency power feeder to the navigation light panel (conductor provided AC power from the inverter to the nav light panel). Over-current protection must be designed to protect the conductors (UL Listed 489) & meet the requirements of 46CFR 111.50-2, 111.50-3, 111.50-5, & 111.75-17(a).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 September 2016
Resolved 22 August 2016
Resolution: Attended vessel. Verified installation of UL 489 Listed circuit breaker in feeder providing emergency AC power from the inverter to the navigation light panel.
Fire Fighting › Fire Pumps › Power Source
Issued 11 August 2016
Resolved
Provide low-voltage release for fire/bilge/ballast pump #2 motor contactor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 September 2016
Resolved 22 August 2016
Resolution: Verified contactor control push buttons were replaced with a selector type switch to provide Low-voltage release as required. All sat.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 August 2016
Resolved
Label all DC power panels and circuits IAW the USCG approved one-line diagrams.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 September 2016
Resolved 1 September 2016
Resolution: Verified panels were labeled IAW DC one-line diagram. DC one-line diagram is still under review for approval by MSC. Will have labels updated if they have changed once the one-line diagram is approved.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 11 August 2016
Resolved
Ensure over-current protection of steering motor is in accordance with 46CFR 58.25-55
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 September 2016
Resolved 1 September 2016
Resolution: Received information from motor contactor and overload relay manufacturer and verified overload relays are not set up to trip the motor contactor on overload. Verified that overload alarm is activated by the overload relays when they actuate.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 11 August 2016
Resolved
Provide steering alarms which meet all the requirements for operation, alarm type, & the location of audible and visual indicators required by 46CFR 58.25-25(d) 1 thru (d)3 and (e)1 thru (e)3
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 11 May 2017
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 11 August 2016
Resolved
Install Bridge, Navigation, Watch, Alarm System (BNWAS) as required by 74 SOLAS 2014, Chapter V, Regulation 19,2.2.3.3.5
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 11 May 2017
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 August 2016
Resolved
Provide spare magnetic compass that is interchangable with the ships primary magnetic compass as required by 74 SOLAS 2014, Chap V, Regulation 19.2.2.1
Action required: 705 - Other - as specified
Due 11 September 2016
Resolved 12 August 2016
Resolution: Verified vessel purchased and stores a replacement Magnetic compass onboard.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 August 2016
Resolved
Repair leak on OWS water pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2016
Resolved 12 August 2016
Resolution: Verified leak on OWS pump was corrected
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 11 August 2016
Resolved
Provide current copies of the Internation Code of Signals and IAMSAR Manual as required by 74 SOLAS 2014, Chapter V, Regulation 21
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 September 2016
Resolved 1 September 2016
Resolution: Verified current copies of the IAMSAR Manual and International Code of Signals were onboard.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 11 July 2016
Resolved
Provide updated compass deviation table. New equipment was installed on the vessel after date listed on deviation table.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 15 July 2016
Resolution: Verified magnetic compass deviation table was provided on the bridge.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 July 2016
Resolved
Provide approved first aid kit. Items in current kit were expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 11 August 2016
Resolution: Verified approved first aid kit was on board.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 11 July 2016
Resolved
Provide SOLAS approved lights for all lifejackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 11 August 2016
Resolution: Verified lifejackets were provided with SOLAS approved lights
Lifesaving › Rescue Boat › Carriage Requirement
Issued 11 July 2016
Resolved
Demonstrate operation of rescue boat.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 11 August 2016
Resolution: Witnessed proper launching and operation of rescue boat
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 11 July 2016
Resolved
Provide paper copies of all CG approved plans and comment letters.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 12 July 2016
Resolution: Accepted flash drive from operator that contained all USCG approved plans and associated comment letters in PDF format.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 11 July 2016
Resolved
Make engine technical files & applicable international air pollution prevention documents available for inspection.
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 11 August 2016
Resolution: Verified required EIAPP certificates and technical files for the installed diesel engines were on board.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 July 2016
Resolved
Complete annual inspection no later than 11 August.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 11 August 2016
Resolution: Completed annual inspection on 11 AUG 2016