Records from 2005 to 2026. Most recent: inspection, 27 January 2026.
Documentation record
Registered dimensions (L × B × D)202.9 ft × 54.0 ft × 19.0 ft
Registered tonnagegross 1,659 / net 571
ITC dimensions (L × B × D)202.9 ft × 54.0 ft × 19.0 ft
ITC tonnagegross 1,659 / net 571
BuilderTHOMA-SEA BOAT BUILDERS, INC. · LOCKPORT, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT OF IBERIA, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it571 - Convention (Subpart B), Net Ton
1659 - Convention (Subpart B), Gross Ton
2653 - Dead Weight, Gross Ton
3971 - Displacement, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
27 January 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8302826
7 January 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8064369
11 December 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8046044
20 March 2024
Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7888382
20 April 2023
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7672482
7 February 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7633580
2 June 2022
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7466325
30 March 2022
COI Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7421651
26 October 2020
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7085246
17 September 2019
Examination of Repairs · MTSA Verification · Administrative Inspection · COI Inspection · Drydock Exam · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6814087
23 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6184280
22 February 2017
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6103711
13 June 2016
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5910288
25 February 2016
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5822193
25 February 2016
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5826652
27 June 2014
Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4905443
15 March 2010
Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3694902
2 July 2009
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3502103
29 February 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3155791
24 December 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3137466
21 April 2005
Initial Certification · Initial Construction-Excluding Oversight · Welding Related Inspections Qualification Testing · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2340085
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 December 2024
Resolved
When the cognizant OCMI deems inspection necessary, the repairs or alterations must be inspected by a marine inspector.
Work list Item's
-Various vents throughout the deck replace/repair.
-Gauging collision bulkhead P/S chain lockers 18" from the deck.
-Make ready for inspection emergency bilge suction valve and port bilge suction.
-Port cooling void gauging called out by ABS.
-Aft peak ballast gauging called out by ABS.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 18 December 2024
Resolution: All worklist item's have been cleared.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 7 February 2023
Resolved
Ventilation shutdowns for fire-fighting system must operate properly. Identified fire damper in engine room not functional.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2023
Resolved 19 April 2023
Resolution: Vessel rep sent via email a video showing the newly installed fire dampner working.
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 27 April 2022
Resolved
Shipboard Oil Pollution Emergency Plan must be approved. Plan expired in 2020.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2022
Resolved 28 April 2022
Resolution: Approved SOPEP onbaord
01 - Certificates & Documentation › 013 - Documents › Shipboard marine pollution emergency plan for NLS
Issued 27 April 2022
Resolved
Non Tank Vessel Response Plan must be approved. Plan expired in 2020.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2022
Resolved 28 April 2022
Resolution: Approved NTVRP onboard
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 April 2022
Resolved
Fire team member did not fit in the fire suit. Obtain proper sized fire suit.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2022
Resolved 28 April 2022
Resolution: Proper sized suits were onboard and drills were conducted, SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 27 April 2022
Resolved
Each survival craft must not require lifting from its stowed position in order to launch. The port life rafts are secured to a rolling platform, able to release the rafts over the side. However, on the railing system was sseized to the rail due to an over tightened retaining d clip.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2022
Resolved 28 April 2022
Resolution: D-ring was loosened allowing for proper operation of the launching device.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 April 2022
Resolved
Each class 1 door on a vessel in ocean service must be designed to withstand a head of water. Multipule watertight doors in the engine room and the emergency escape hatches did not seal properly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2022
Resolved 28 April 2022
Resolution: Gaskets were replaced and dogs adjusted. Chalk test SAT.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 27 April 2022
Resolved
F/O purifier must shut down with the transfer pump emergency remote shut down.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 28 April 2022
Resolution: Purifier pump was wired into the transfer pump emergency shutdown. Test SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 April 2022
Resolved
The employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Alcohol test strips are expiring in 2 days and need to be replaced before expiration.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2022
Resolved 2 May 2022
Resolution: Alcohol test strips were purchased and placed onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 27 April 2022
Resolved
Each OSV must carry at least one rescue boat. Each rescue boat must be approved under approval series 160.156. The rescue boat had a small area of damaged fiberglass on the STBD side mid-ship below the water line.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 20 May 2022
Resolution: Repair report and photos provided. SAT.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 27 April 2022
Resolved
Each vessel must have a permanently exhibited, for the guidance of the master and crew members, general arrangement plans showing, for each deck, the various fire-retardant bulkheads together with particulars of the -Fire-detection systems; manual-alarm systems; etc. The on board fire control plans did not match. One plan was last updated in 2008 and the others were updated in 2007. Confirm the fire control plan matches the vessel’s outfitted systems and ensure all plans match.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 2 May 2022
Resolution: Proper fire control plan was placed in the tube onboard the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 27 April 2022
Resolved
Each embarkation ladder must be approved under approval series 160.117 or approval series 160.017. Both the port and starboard embarkation ladders D rings and the thimble on the upper most portions of the ladders were severely corroded and no longer serviceable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 28 April 2022
Resolution: Hardware was replaced and operated SAT.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 March 2010
Resolved
Replace emergency light at stbd life-raft muster station.
Action required: 705 - Other - as specified
Resolved 26 March 2010
Stability › Watertight Integrity › General
Issued 6 April 2007
Resolved
Provide Approved Structural Plans for Bulkhead 45 Water Tight Door Drawing and Letter, with ABS approval and MSC approval.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 June 2007
Resolved 6 April 2007
Resolution: Provided to MSU Houma
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 21 April 2005
Resolved
Provide Approved Fixed CO2 Drawing and Letter, with ABS approval and MSC approval.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 June 2007
Resolved 6 April 2007
Resolution: Provided to MSU Houma.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 21 April 2005
Resolved
Provide Approved Fixed Fire Detection System Drawing and Letter, with ABS approval and MSC approval.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 June 2007
Resolved 6 April 2007
Resolution: Provided to MSU Houma
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 21 April 2005
Resolved
Provide Approved Structural A Class Division for Bulkhead 45 Drawing and Letter, with ABS approval and MSC approval
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 June 2007
Resolved 6 April 2007
Resolution: Provided to MSU Houma
Fire Fighting › Ventilation Systems › Ducts
Issued 21 April 2005
Resolved
Provide Approved Ventilation System with Fire Dampers for Bulkhead 45 Drawing and Letter, with ABS approval and MSC approval.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 June 2007
Resolved 6 April 2007
Resolution: Provided to MSU Houma