MAURY USCG vessel records Sign in
← All vessels

LOREN C

LOREN C is a 2007 industrial vessel. The Coast Guard has recorded 45 inspections since 2006, most recently in July 2026, along with 26 deficiencies — 1 with no resolution recorded — and 2 operational controls, 1 with no removal date recorded.

Records from 2006 to 2026. Most recent: inspection, 7 July 2026.

Built
2007
Last inspected
7 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9383792 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDP2092
865667
Flag
UNITED STATES
367189890
Maury page id
psix-865667

Inspections, by type

…with no type recorded2
…past their stated due date1
Years with a record 19 calendar years (2006–2026)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)201.0 ft × 48.0 ft × 16.0 ft
Registered tonnagegross 996 / net 677
ITC dimensions (L × B × D)201.0 ft × 48.0 ft × 16.0 ft
ITC tonnagegross 1,201 / net 381
BuilderTHOMA-SEA SHIP BUILDERS LLC · LOCKPORT, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 March 2026 · expires 30 April 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it677 - Regulatory (Subpart C or D), Net Ton
381 - Convention (Subpart B), Net Ton
996 - Regulatory (Subpart C or D), Gross Ton
1201 - Convention (Subpart B), Gross Ton
1866 - Dead Weight, Gross Ton
1049 - Displacement, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP2092MMSI 367189890 · active · compulsorily equipped · granted 12 September 2023, expires 12 September 2033
WDD7691MMSI 367189890 · cancelled · compulsorily equipped · granted 25 May 2017, cancelled 7 September 2023 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 45

7 July 2026 Vessel Attendance · Excursion Permit · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8420474
19 May 2026 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8378130
5 May 2026 In-Service Inspection · Excursion Permit · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8353476
25 February 2026 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8315305
16 July 2025 Deficiency Check · Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8186911
27 March 2025 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8100930
20 February 2025 Administrative Inspection · Periodic Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8082354
25 April 2024 MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7897939
25 April 2024 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7912414
7 December 2023 Annual Inspection · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7837800
6 September 2023 MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7786338
9 December 2022 MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7600481
4 October 2022 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7566627
3 January 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7374821
13 October 2021 MARPOL Annex I Examination · COI Inspection · Exemption
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7327704
31 August 2021 Administrative Inspection · Excursion Permit · In-Service Inspection · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7300759
7 June 2021 Exemption
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7218501
15 December 2020 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7107684
18 August 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7037346
22 July 2019 MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6758902
12 July 2019 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6747129
8 January 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6607484
27 November 2017 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6313328
13 November 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6306166
22 September 2017 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6272822
18 September 2017 COI Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6269682
4 January 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6057948
30 August 2016 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5989546
19 January 2016 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5799710
9 December 2015 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5759033
28 September 2015 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5731015
18 September 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5722193
22 October 2014 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5008582
22 October 2014 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5034823
29 May 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4327084
7 December 2011 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4204497
10 January 2011 MARPOL Annex VI Survey · Examination of Repairs · Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3924162
9 December 2010 Hull Examination · Periodic Inspection · Administrative Inspection · Internal Structural Exam · Drydock Exam · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3907748
7 October 2010 Administrative Inspection
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 3875275
5 October 2010 Drydock Extension
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3864377
16 September 2010 Drydock Extension
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3849874
8 December 2009 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3646061
4 November 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3357239
22 March 2007 Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 2892815
4 May 2006 Construction Oversight · Initial Certification · Deadweight Survey · MTSA Verification · Inclining Experiment
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2640320

Deficiency record · 26

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 March 2025 Resolved
Upon the installation of the portable accommodation module shall inspect the installation, workmanship and testing. DEF will be cleared upon the satisfaction of the OCMI.
Action required: 705 - Other - as specified
Due 7 January 2026
Resolved 24 July 2025
Resolution: PAM's removed and no longer onboard.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 20 February 2025 Resolved
Vessel did not have a Steering gear instruction placard. Vessel is to place a placard at the control station. 46CFR97.37-33
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2025
Resolution: Vessel placed emergency procedures at the operating station. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 February 2025 Resolved
Hydraulic storage tank in steering room has a broken sight glass. Vessel is to replace sight glass. 46CFR90.20-1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 March 2025
Resolution: Sightglass replaced. All SAT
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 20 February 2025 Resolved
Vessel did not have a line diagram, operation procedures , and proper markings for OWS. Vessel is to place placards at the operating station prior to sailing foreign. 46CFR162.050-11 and 33CFR155.360
Action required: 705 - Other - as specified
Resolved 24 July 2025
Resolution: Verified diagram and procedures in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 February 2025 No resolution recorded
PSTPs were not performed on propulsion and generators, documents did not match current vessels configuration. Vessel is to resubmit PSTP to MSC for approval. 46CFR61.40
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2025 — due date passed with no resolution recorded
Resolution: *Extended to coincide with next annual inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 February 2025 Resolved
Vessel carries two fire-fighter outfits and currently has 4 SCBAs onboard. Vessel is required to have two spare charged SCBA for each breathing apparatus, were two additional will complement the regulation. SOLAS 74(09)II-2/10.2.5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2025
Resolution: Vessel provided documentation of 2 additional certified SCBAs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 December 2022 Resolved
Prior to the installation aboard ship diagrams of all piping shall be submitted for approval. Two liquid mud pumps installed without plan approval. Submit plans to OCMI and Commandant for approval before operating. 46 CFR 56.01-10
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 24 July 2025
Resolution: Pumps are no longer in use or connected to where they could function. Operator has no intention of using pumps.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 January 2022 Resolved
The emergency lighting must automatically actuate upon failure of the main lighting unless a vessel is equipped with a single source of power for emergency lighting, it must have individual battery-powered lighting that is automatically actuated upon loss of normal power. The emergency generator that supplies the emergency lighting was not functional at the time of the inspection. Provide adequate emergency lighting to the attending MI.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2022
Resolved 3 January 2022
Resolution: Vessel rep provided video evidence of egen and emergency lighting actuating under loss of power.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 September 2021 Resolved
At each inspection for certification, the marine inspector shall conduct such tests and inspections of the main propulsion. Fuel leak was observed on the fuel return lines for the Port and Stbd MDE. Repair to the satisfaction of the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 7 September 2021
Resolved 8 September 2021
Resolution: Fuel return lines replaced satisfactorily without leaks.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 September 2021 Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port required to be marked. Additionally, renew batteries in all water lights.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2021
Resolved 8 September 2021
Resolution: Lifebuoy batteries replaced and stenciling reapplied.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 15 December 2020 Resolved
Quarterly qualified individual notification exercises not conducted.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 December 2020
Resolved 15 December 2020
Resolution: Vessel conducted notification exercise during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 15 December 2020 Resolved
Vessel unable to demonstrate over speeds on all internal combustion engines due to unavailability of service technician. Demonstrate over speeds to attending USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2021
Resolved 19 January 2021
Resolution: Vessel demonstrated overspeed shutdowns.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 July 2019 Resolved
Button on transfer control panel for emergency steering was inoperable and stuck. IAW 46 CFR 58.25-70(k) main and auxiliary steering gears must be arranged such that control is available from local and remote locations.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 October 2019
Resolved 24 July 2019
Resolution: Button was replaced and system was operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 July 2019 Resolved
Improper gasketing on bow thruster compartment watertight door and port side engine emergency escape hatch on deck. IAW 46 CFR 131.520, all watertight openings and exposed hatches shall be made watertight by proper use of gasketting.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2019
Resolved 24 July 2019
Resolution: Gasket was replaced and is satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 July 2019 Resolved
All watertight doors were not properly adjusted and not watertight. IAW 46 CFR 131.520, all watertight openings shall be watertight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2019
Resolved 24 July 2019
Resolution: All watertight doors/hatches were adjusted and satifactory seals.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 July 2019 Resolved
Battery installation for emergency generator was not secured for sea and was not covered for protection. IAW 46 CFR 129.220(a), electrical equipment shall be installed suitable for roll, pitch, and vibration of vessel.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 22 July 2019
Resolved 22 July 2019
Resolution: Owner cleared on the spot. Installed battery box housing for battery within space.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 July 2019 Resolved
Wasted hose on CO2 extinguisher for flammable locker. IAW 46 CFR 132.350, each system must be inspected for corrosion and condition, then repaired if deficient.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2019
Resolved 24 July 2019
Resolution: Hose was replaced and system is satifactory.
Documentation › Logs/Records › Oil Record Book
Issued 11 October 2017 Resolved
Provide documentation attesting to an internal audit from the company environmental officer for Oil Record Book keeping due to the numerous anomalies, missing entries and unaccounted for quantities of oil as required by 33CFR.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 27 November 2017
Resolution: Provide documentation attesting to the an internal audit of the ORB and record keeping.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 October 2017 Resolved
Demonstrate proper operation of the OWS once capable. Bilge holding tank is currently dry.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 13 November 2017
Resolution: Attending Marine Inspector witnessed proper operation of OWS.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 4 January 2017 Resolved
Provide an updated Fire Control Plan to show the location of Electrical Driven Fire Pumps to the OCMI for review and acceptance.
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 9 February 2017
Resolution: Recieved/reviewed fire control plan, sent 02 approved plans to vessel and 01 copies of the approval letter.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 9 December 2015 Resolved
Provide approved test procedured for all automated machinery. 46 CFR 127.110(f)
Condition: Improper/Lack of Maintenance
Due 29 February 2016
Resolved 19 January 2021
Resolution: Vessel has approved ATPs.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 9 December 2015 Resolved
Provide lagging to both service generators and emergency generator. No exposed exhaust piping. 46 CFT 129.320
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2015
Resolved 19 January 2016
Resolution: Insulation was added to areas identified.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 October 2014 Resolved
Provide lighting covers and cages in reefer storage.
Action required: 705 - Other - as specified
Due 22 November 2014
Resolved 5 November 2014
Resolution: protective cage''s installed properly
Documentation › Logs/Records › Oil Record Book
Issued 22 October 2014 Resolved
Provide ORB part 1 for machinery and maintain log record for 3 years on board. To be corrected at next annual inspection.
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 5 November 2014
Deck/Cargo › Mooring/Anchoring › Winch
Issued 22 October 2014 Resolved
Prove proper operation of stbd anchor windless.
Action required: 705 - Other - as specified
Due 22 November 2014
Resolved 12 November 2014
Resolution: Anchor windless working properly
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 7 December 2011 Resolved
Prove proper operation of emergency generator IAW 46 CFR 112.50-1
Action required: 705 - Other - as specified
Due 7 January 2012
Resolved 5 January 2012
Resolution: Proved proper operation of Emergency Generator IAW 46 CFR 112.50-1

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.