LIBERTY is a 2006 freight ship. The Coast Guard has recorded 56 inspections since 2016, most recently in June 2026, along with 20 deficiencies, 1 operational control and 1 casualty investigation in 2022.
Records from 2016 to 2026. Most recent: inspection, 17 June 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Registered dimensions (L × B × D)636.9 ft × 105.8 ft × 68.5 ft
Registered tonnagegross 61,321 / net 23,567
ITC dimensions (L × B × D)636.9 ft × 105.8 ft × 68.5 ft
ITC tonnagegross 61,321 / net 23,567
BuilderMITSUBISHI HEAVY IND · JAPAN · built 2006
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWILMINGTON, DE
Trade endorsementsRegistry, Canadian bulk freight
DocumentationValid · issued 5 November 2025 · expires 31 December 2026
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22271 - Dead Weight, Ton 40947 - Displacement, Ton 23567 - Convention (Subpart B), Net Ton 61321 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 56
17 June 2026Internal Structural Exam · Drydock Exam · MSP COI Oversight · MTSA/ISPS Verification · COI Inspection · Vessel Attendance · Hull Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8406565
31 May 2026Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8384430
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 14 July 2026Resolved
Where davit arms are recovered by power, safety devices shall be fitted which will automatically cutoff the power before the davit arms reach the stops in order to prevent overstressing the falls or davits, unless the motor is designed to prevent such overstressing. During COI inspection, davit limit switch was not operational. Vessel to operate davit using submitted risk mitigation plan until repairs made. Make permanent repairs to satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2026
Resolved 16 July 2026
Resolution: Accepted by LR as AI-S-033
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 1 November 2022Resolved
The OCMI will determine the specific manning levels for vessels required to have certificates of inspection by part B of subtitle II of title 46 U.S.C. The masters or individuals in command of all vessels, whether required to be inspected under 46 U.S.C. 3301 or not, are responsible for properly manning vessels in accordance with the applicable laws, regulations, and international conventions. Vessel reports sailing short 01 oiler; return to full complement.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2022
Resolved 21 November 2022
Resolution: VSL master reported to be at full manning compliment.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 27 September 2022Resolved
The Company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situations. The safety management system should provide for specific measures aimed at promoting the reliability of such equipment or systems. These measures should include the regular testing of stand-by arrangements and equipment or technical systems that are not in continuous use. The inspections mentioned in 10.2 as well as the measures referred to 10.3 should be integrated in the ship's operational maintenance routine. During the inspection noted multiple CO2 portable fire extinguishers missing pressure gauges. Reviewed NSE for the monthly job assignment for inspecting portable fire extinguishers but there were no procedures, instructions, or checklists on how to inspect this equipment. There is also no procedure within the SMS / JIBE.
Cite: SOLAS IX/Reg 3.1
ISM Code Part A 10.2-10.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2022
Resolved 26 October 2022
Resolution: Received satisfactory class report from DNV accepting CG-835s.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 27 September 2022Resolved
The company should ensure that valid documents are available at all relevant locations; changes to documents are reviewed and approved by authorized personnel; and obsolete documents are promptly removed.
• Only a copy of the ISSC was on board; the original certificate could not be located. The DNV Stability Declaration dated 2017-04-10 was not provided during inspection.
• In 2019, a crewmember changed the Lightship calculations for required DNV quarterly stability loading tests in 2019 with no reviewed or approved authorization(s).
• Multiple obsolete documents were found in the certificates binder (Certificate of Documentation, Non-tank Vessel Response Plan approval letters, and SOPEP approval letters). The Garbage Record Book (Garbage) had over three years of log entries and the provided Garbage Record Book dates did not correspond with SMS/JIBE.
Cite: SOLAS IX/Reg 3.1
ISM Code Part A 11.2.1, 11.2.2, and 11.2.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2022
Resolved 26 October 2022
Resolution: Received satisfactory class report from DNV accepting CG-835s.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 27 September 2022Resolved
The master shall be supplied with such information satisfactory to the Administration as is necessary to enable him by rapid and simple process to obtain accurate guidance as to the stability of the ship under varying conditions of service…where any alternations are made to a ship so as to materially affect the stability information supplied to the master, amended stability information shall be provided. While reviewing Loading/stability program Autoload 6.0/Stowage Planning System, identified quarterly stability loading tests in 2019 did not properly capture the Lightship calculations based on DNV approvals. 18803 MT was used in 2019 and 18676 MT is what should be used based off approvals provided by vessel representatives. Also, the DNV Stability Declaration dated 2017-04-10 was not provided to inspection team.
Cite: SOLAS (2004) II-1/Reg 22.1 and 22.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2022
Resolved 26 October 2022
Resolution: Received satisfactory class report from DNV accepting CG-835s.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 27 September 2022Resolved
Every ship of 100 gross tonnage and above, and every ship which is certified to carry 15 or more persons...shall carry a garbage management plan which the crew should follow. The garbage managemnt plan requires the development of a diagram showing the major collection/storage locations to include a legend that clearly defines what category of garbage is stowed at each location.
Cite: MARPOL Annex V/ Reg10.2
33 CFR 151.57
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2022
Resolved 18 October 2022
Resolution: Received diagram via email clearly defining storage locations/categories.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 September 2022Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. A power strip was utilized to recharge Fire Locker #1 radios.
Cite: SOLAS (2004) II-1/Reg 40.1.3
Action required: 10 - Deficiency Rectified
Resolved 27 September 2022
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 26 September 2022Resolved
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. The emergency fire pump cannot be controlled from the bridge and does not have a fire main pressure indicator or a fire main low pressure alarm.
Cite: SOLAS (2009) II-2/Reg 46.2; 46 CFR 62.35-15, 46 CFR 62.50-20(d)(2), NVIC 1-13 CH-1 Enclosure (2) 3.2.1.1.C.x
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2022
Resolved 24 October 2022
Resolution: Identified associated CG-835's finding number in DNV's Veracity database.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 September 2022Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. Structural fire protection missing in engine room above #2 Main Diesel Generator.
Cite: SOLAS (2009) II-2/ Reg 14.2.1.1.1
Action required: 10 - Deficiency Rectified
Resolved 27 September 2022
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2022Resolved
Cables and wiring shall be installed and supported in such manner as to avoid chafing or other damages. Metal buckles or other suitable methods should secure metallic band strapping used for cable support. Metallic band strapping used for cable support should be steel and corrosion treated if not a corrosion resistant material.
Horizontal wire run on mid-engine platform near fuel oil pumps were secured by plastic ties. Ties need to be of
the metal type.
Cite: SOLAS II-1/45.5.4
IEEC 45-2002 25.5
Action required: 10 - Deficiency Rectified
Resolved 27 September 2022
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2022Resolved
Cables and wiring shall be installed and supported in such manner as to avoid chafing or other damages. Metal buckles or other suitable methods should secure metallic band strapping used for cable support. Metallic band strapping used for cable support should be steel and corrosion treated if not a corrosion resistant material. Horizontal wire run in lower engine room stbd side near emergency exit were secured by plastic ties. Ties need to be of the metal type.
Cite: SOLAS II-1/45.5.4
IEEC 45-2002 25.5
Action required: 10 - Deficiency Rectified
Resolved 27 September 2022
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2022Resolved
Cables and wiring shall be installed and supported in such manner as to avoid chafing or other damages. Metal
band strapping used for cable support should be steel and corrosion treated if not a corrosion resistant material. Vertical wire run in boiler space above burner control panel was secured by plastic ties. Ties need to be of the metal type.
Action required: 10 - Deficiency Rectified
Resolved 27 September 2022
Resolution: Corrected on the spot.
The OCMI will determine the specific manning levels for vessels required to have certificates of inspection by part B of subtitle II of title 46 U.S.C. The masters or individuals in command of all vessels, whether required to be inspected under 46 U.S.C. 3301 or not, are responsible for properly manning vessels in accordance with the applicable laws, regulations, and international conventions.
Vessel reports sailing short two oilers (1 currently onboard, 3 required by COI minimum safe manning) and one AB (3 ABs, 1 OS, and one additional 3M currently onboard; 6 ABs required by COI minimum safe manning).
Provide complement of minimum manning as required by COI prior to departure.
46 CFR 15.801
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2022
Resolution: The vessel is now manned in accordance with its COI.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 19 February 2019Resolved
Ships fitted with AIS shall maintain AIS in operation at all times except where international agreements, rules or standards provide for the protection of navigational information. Subject vessel's AIS is inoperable; conduct approved repairs.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 22 February 2019
Resolved 22 February 2019
Resolution: New AIS unit installed and operationally tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 2 January 2019Resolved
During underwater survey, rudder clearances were not taken due to adverse weather conditions and excessive wind and currents. Perform rudder bearing clearance readings IAW class report - NLT 22Feb2019. survey statement loaded in documents.
Action required: 705 - Other - as specified
Due 22 February 2019
Resolved 29 January 2019
Resolution: Received survey statement stating rudder bearings readings were performed.
Lifesaving › Launching Appliances › Falls
Issued 7 May 2018Resolved
Before ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Repair and prove proper ooperation of life-boats primary releasing mechanism.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 June 2018
Resolution: Witnessed proper operation of life boat launching device.
Lifesaving › Inflatable Liferafts › Servicing
Issued 10 October 2017Resolved
Vessel is required to have USCG approved life-raft and proper annual servicing. Vessel is granted an extension to complete proper life-raft replacement and servicing by next USCG annual inspection or expiration date of current life-raft servicing certificate +05 months, whichever is earlier.
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 7 May 2018
Resolution: Verified serviced life-rafts.
Provide EPA issued EIAPP certificates for main engine and auxiliaries. In the interim the vessel is authorized to sail on a short-term IAPP issued by the authorized classification society, DNV-GL, which is to be accompanied by the IAPP supplements issued by DNV-GL.
Action required: 705 - Other - as specified
Due 25 September 2017
Resolved 2 September 2017
Resolution: Received copy of EPA issued EIAPP.
2050 - Main diesel engine is currently inoperable due to mechanical issues involving the #4 piston and stuffing box. SOLAS 74 (2014) Ch. 1/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2016
Resolution: Recieved class report and technicians report.
Personnel › Training › Cargo Safety
Issued 15 June 2016Resolved
A Hazmat Emplyer shall ensure that each of it's HAZMAT employees is trained in accordance with 49CFR172. PSCO observed that not all applicable crew had HAZMAT training as required. 49CFR172.702(a). 40c
Action required: 15 - Rectify deficiencies by next port
Resolved 16 October 2016
Resolution: Vessel provided training to all vessel personel.
18 October 2022Routine · role: Involved in a Marine Casualty · activity 7579753
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.