MAURY USCG vessel records Sign in
← All vessels

MTM SHANGHAI

MTM SHANGHAI is a 2006 tank ship. The Coast Guard has recorded 24 inspections since 2007, most recently in June 2025, along with 11 deficiencies and 9 operational controls.

Records from 2007 to 2025. Most recent: inspection, 19 June 2025.

Built
2006
Last inspected
19 June 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9345908 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V9600
866241
Flag
SINGAPORE
—
Maury page id
psix-866241

Inspections, by type

…with no type recorded11
Years with a record 13 calendar years (2007–2025)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it25289 - Displacement, Metric Ton
19886 - Dead Weight, Metric Ton
6365 - Convention (Subpart B), Net Ton
11641 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

19 June 2025 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8157453
3 July 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7948208
12 October 2023 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7804447
10 April 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7427279
20 February 2020 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6912347
17 January 2019 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6611576
9 December 2017 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6314740
30 November 2016 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6047104
28 July 2012 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4392998
10 December 2010 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3908494
22 November 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3896588
10 November 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3889200
9 February 2010 COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3677339
23 January 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3399127
16 January 2009 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3395264
8 January 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3387690
8 January 2009 MARPOL Annex I Examination · MARPOL Annex II Examination · COC-CHEM Renew · PII Safety Exam · ISPS I Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3390597
22 September 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3368574
14 September 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3324767
21 May 2008 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3208389
27 December 2007 MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex II Examination · COC-CHEM Annual · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3121256
26 December 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3121284
2 September 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3045703
5 May 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2922727

Deficiency record · 11

Documentation › Manuals/Policy Documentation › Procedures and Arrangements Manual (NLS)
Issued 30 November 2016 Resolved
2545-Reports/analysis of non conformities-The company and ship shall comply with req. of ISM Code: Company should establish procedures to control documents relevant to SMS: obsolete documents are properly removed. Outdated P&A manual was given to PSCO during exam. Manual didn’t meet Annex II req. New P&A was on board. Master filed non conformity report. SOLAS74 (09) XI/3.1 ISM CODE 11.2.3 10c
Action required: 705 - Other - as specified
Resolved 30 November 2016
Resolution: Received, reviewed and accepted non conformity report from Master that was submitted to the company
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 10 December 2010 Resolved
A ship when in a port of another Party is subject to inspection by officers duly authorized by such Party concerning oper requirements under Annex, where there are clear grounds for believing that the master or crew are not familiar w/ essential shipboard procedures relating to the prevention of pollution oil. [name withheld] couldn't demonstrate proper ops of the system. MARPOL Annex I, Reg 11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2010
Resolution: Received Class report attesting to the proper operation of the ODME. CG Examiner witnessed operational test by [name withheld] of the ODME.
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 10 December 2010 Resolved
Vessel must be fitted with a pressure sensing device that senses the pressure in the main vapor collection line with a high and low pressure alarm. Vessel could not demonstrate proper operation of the high and low pressure alarms. SOLAS XI-1 Reg 4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2010
Resolution: Received class report attesting to the proper operation of the high and low pressure alarms. CG Examiner witnessed successful operational test of alarms by [name withheld].
Lifesaving › Lifeboat › Markings
Issued 10 December 2010 Resolved
The port and starboard lifeboats are required to have the vessel name on each side of the lifeboats bow. The vessel name is missing from the outboard side of both the port and starboard lifeboats. SOLAS 74 (2004 con ed.) Ch III Reg 31.1.1.1; LSA Ch IV/4.4.9.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2010
Resolution: Received Class report attesting to the proper marking of the lifeboat both inboard and outboard sides. Cg Examiner visually inspected and confirmed markings applied to both sides of lifeboat.
Pollution Prevention/Response › Response Equipment › Protective Clothing
Issued 10 December 2010 Resolved
The vessel is required to maintain three complete sets of safety equipment permitting personnel to enter a gas-filled space. All three suits onboard designed for entry were wasted, melted and corroded. IBC Code 14.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2010
Resolution: Received Class report attesting to the vessel receiving three chemical suits.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 10 December 2010 Resolved
The intermediate and annual surveys and inspections of the outside of the ships bottom shall be endorsed on the Cargo Ship Safety Construction Certificate. The Cargo Ship Safety Construction Certificate currently onboard vessel is not endorsed to reflect any hull exams. SOLAS 74 (2009 Con Ed.) Ch -I Reg 10(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2010
Resolution: Received Class report documenting the correction of the certificate. NKK rewrote the cert in accordance with there policy.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 10 December 2010 Resolved
At all times while the ship is in service, fire fighting appliances shall be maintained ready for use. Two portable fire extinguishers in way of the port and starboard cargo manifolds were missing. SOLAS 74 (2009 Con Ed.) Ch II-2/14.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2010
Resolution: Received Class report verifying that two extinguishers were replaced new.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 December 2010 Resolved
The vessel is required to have lifebuoys fitted with grablines that are secured at 4 equidistant points to form 4 loops. The lifebuoys on the lifeboat deck, starboard side, have deteriorated and the grablines are not being secured on three sides. SOLAS 74 (2004 Con Ed) Ch III Reg 32.1.1; LSA Ch II 2.1.1.8
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2010
Resolution: Received Class report attesting to the replacement of all life buoys that were deteriorated.
Lifesaving › Hand Flares › Storage
Issued 10 December 2010 Resolved
Flares shall be contained in water-resistant casings. The hand flares located in the port and starboard lifeboats and on the bridge are not contained in water resistant casings. SOLAS 74 (2004 Con Ed.) Ch III/6.3; LSA Ch III/3.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2010
Resolution: CG Examiner witnessed proper storage of Flares in the lifeboat and on the bridge.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 10 December 2010 Resolved
Each tank vessel must be equipped with an intrinsically safe high level alarm. Vessels #9P tank high level alarm was alarming while the tank was void of cargo and gas free. 33CFR155.480/46 CFR 39.20-7
Action required: 15 - Rectify deficiencies by next port
Resolved 20 March 2011
Resolution: Received class report from NKK satisfying requirements.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 December 2010 Resolved
Hold back hooks not subject to central control station release are prohibited. The vessel had several class "A" fire doors held open with line. SOLAS 74 (2204 Cons Ed.) Ch II-2 Reg 9.4.1.1.4.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2010
Resolution: Received class report verifying all doors of the class "A" type will not be held open by hold backs. Crew has been instructed to this as well. CG Examiner verified all doors were no longer being held open by hold backs.

Ownership record