← All vessels
BARRACUDA
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southeast District (CGD-SE) · Other hulls named BARRACUDA
BARRACUDA is a 2006 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 2007, most recently in December 2025, along with 125 deficiencies, 7 operational controls and 3 casualty investigations between 2009 and 2022.
Records from 2007 to 2025. Most recent: inspection, 9 December 2025.
- Built
- 2006
- Last inspected
- 9 December 2025
- Documentation
- Expired · documentation file of 10 September 2026
- Deficiencies
- 125 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2009–2022
Identity
1194887
WDJ6799
866295
Flag
UNITED STATES
368000340
Maury page id
psix-866295
Inspections, by type
…with no type recorded10
Years with a record
17 calendar years (2007–2025)
The 35 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)35.7 ft × 14.0 ft × 6.0 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA HAWK INDUSTRIES INC · SEBRING, FL, UNITED STATES · built 2006
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portMARATHON, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationExpired · issued 12 January 2007
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Net Ton
20 - Simplified, Gross Ton
20 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ6799MMSI 368000340 · active · compulsorily equipped · granted 25 July 2017, expires 25 July 2027
WDD7377MMSI 367185630 · expired · compulsorily equipped · granted 8 May 2007, cancelled 8 July 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 35
9 December 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8280125
7 February 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8078223
14 April 2024
In-Service Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7898317
11 April 2024
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7898338
10 April 2024
Type not recorded
No type recorded · Station Marathon · USCG Southeast District (CGD-SE) · Activity 7893760
24 October 2023
COI Inspection · Internal Structural Exam · Examination of Repairs · Deficiency Check · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7813347
20 September 2023
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7795263
4 June 2023
Type not recorded
No type recorded · Station Marathon · USCG Southeast District (CGD-SE) · Activity 7702930
19 October 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7579758
1 June 2022
Type not recorded
No type recorded · Station Marathon · USCG Southeast District (CGD-SE) · Activity 7470459
24 February 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7401143
22 February 2022
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7400163
29 June 2021
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7246859
21 April 2021
Deficiency Check · DAPI Audit · COI Inspection · Plan Review "T" Boat · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7191757
26 May 2020
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6960478
11 February 2020
Drydock Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6907272
27 April 2019
Type not recorded
No type recorded · Station Marathon · USCG Southeast District (CGD-SE) · Activity 6672067
7 March 2019
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6625421
26 November 2018
Type not recorded
No type recorded · Station Marathon · USCG Southeast District (CGD-SE) · Activity 6586576
13 November 2017
Administrative Inspection · Internal Structural Exam · Hull Examination · DAPI Audit · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6332722
27 August 2017
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294440
11 January 2017
Deficiency Check · Administrative Inspection · Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6106694
16 December 2015
Annual Inspection · Internal Structural Exam · DAPI Audit · Administrative Inspection · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5773900
20 March 2014
Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4809058
24 January 2012
Deficiency Check · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4231619
27 August 2011
Type not recorded
No type recorded · Station Marathon · USCG Southeast District (CGD-SE) · Activity 4129426
29 January 2011
Type not recorded
No type recorded · Station Marathon · USCG Southeast District (CGD-SE) · Activity 3938272
9 March 2010
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3697274
7 January 2010
Hull Examination · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3660374
14 May 2009
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3474962
13 May 2009
Deficiency Check · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3474105
29 January 2009
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3401881
7 February 2008
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3143391
28 December 2007
Hull Examination · Initial Certification · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3121810
8 January 2007
Construction Oversight
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2852165
Deficiency record · 125
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 February 2025
Resolved
Renew faded retro on both life floats.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 February 2025
Resolved
Replace rusted out motor mounts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2024
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil that might create a fire hazard or clog bilge pumping systems. Leaking fuel oil was found in the bilges on during a Living Marine Resources boarding on 10APR24. After actions were taken to attempt to rectify that but failed, leaking fuel oil, both atomized and liquid, was again identified during an inspection on 19APR24, creating both pollution and fire hazards.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 19 April 2024
Resolved
The vessel BARRACUDA is a SPV-T, therefore not required
a safety management system (SMS) per regulation. Sector
Key West has found the below deficiencies, in addition to the recently issued code 17c deficiencies on 11APR24(see MISLE activity 7898338) and 14APR24 (the instigating action for this inspection), to be
objective evidence that a serious substandard condition
has not been pro-actively managed by the vessel's owner/
operator, leading to a lack of safety culture on board
the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 April 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel suffered propulsion system failure while underway requiring towing back to mooring. Determine cause of failure and make repairs to the satisfaction of the attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 April 2024
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, or debris, or other matter that might create a fire hazard or clog bilge pumping systems. Accumulation of oil found in engine room bilge with absorbent cloths. Remove oil and cloths, determine sources of leak and make repairs to the satisfaction of attending marine inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 11 April 2024
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not coverd by standards in this subchpater may be inspected in accordance with sandards acceptable to the cognizant OCMI as good marine practice. Main propulsion engine's shaft penetration was found to be leaking sea water at a steady stream into the bilge. Make adjustment or repairs to the main propulsion engine's shaft seal to the satisfaction of the attedning marine inspector. Corrected on the spot.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 11 April 2024
Resolved
Each small battery installation must be located in a well-ventilated space and protected from falling objects. Both battery boxes were found with no terminal protection from falling objects. proveide a means of protection from falling objects and remvoe stored compoennts and debris from the falling battery box to the satisfaction of the attending marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 November 2023
Resolved
Anchor light does not work and also is not mounted in a location that can be seen from 360 degrees. Must make repairs to anchor light and move to top of vessel where it can be seen from all around.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 November 2023
Resolved
Fuel supply and return hoses do not meet the SAE J1942 standard. Must replace both hoses that meet the requirements for CG approved SAE J1942.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 November 2023
Resolved
Two stanchions on the aft railing are broken. Replace both stanchions.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 September 2023
Resolved
The vessel BARRACUDA is a SPV-T, therefore not required
a safety management system (SMS) per regulation. Sector
Key West has found the below deficiencies to be
objective evidence that a serious substandard condition
has not been pro-actively managed by the vessel's owner/
operator, leading to a lack of safety culture on board
the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. New fuel supply piping was installed without notifying the cognizant OCMI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 September 2023
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard or clog bilge pumping systems. Approximately 03 gallons of hydraulic fluid were found in the forward part of the lazarette bilge. Remove hydraulic fluid accumulation from the lazarette bilge. Identify source and make repairs.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 September 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected, and all required guards and protective devices must be in satisfactory condition. The following fire hazards were identified in the vessel’s main machinery space and shall be resolved to the satisfaction of the of the attending marine inspector:
1. The bilge was found to have super saturated oil soaked absorbent pads located under the main propulsion engine. Remove oil-soaked absorbent pads and all oil residue from the bilge.
2. An open lid bucket with approximately 02 gallons of diesel fuel on the port side of the main engine was present. Remove hazard.
3. Numerous bottles of compressed flammable materials were stored throughout the engine space. Remove hazard.
4. The main propulsion engine’s crank case vent was found to be improperly installed and venting directly onto the engine’s main air intake filter resulting in filter oil saturation. Properly install the main propulsion engine’s crank case vent.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 September 2023
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment,
materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Main propulsion engine’s shaft penetration was found to be leaking sea water at a steady stream into the bilge. Make adjustment or repairs to the main propulsion engine’s shaft seal.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to prevent electrical ignition of flammable vapors. Battery system terminal board found mounted directly to the main engine’s metallic fuel supply line. Remove terminal board from its current location and install in a suitable location.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2023
Resolved
All cable and wire must be protected by metal coverings or other suitable means if in areas subject to mechanical abuse. The positive cable for the main engine’s starting system was found to be pinched between deck grating and the hull and installed without protection across a stepway near the front of the engine. Install protection on the main engine’s positive starting cable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2023
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Multiple exposed electrical wire connections found in underneath the main engine, in the overhead in the port aft section of the engine room and in the starboard overhead of the lazarette. Place all connections within a suitable enclosure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2023
Resolved
Nonmetallic piping must not be used in gasoline or diesel fuel systems unless they meet SAE J1942 and J1475 specifications. Flexible fuel hose installed for the main engine fuel supply line does not meet SAE J1942 and J1475 specifications standards. Replace fuel supply line with materials meeting required standards.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The vessel’s port fuel tank located in the lazarette was found to have an inoperable shutoff valve installed. Repair or replace the inoperable fuel shutoff valve.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 September 2023
Resolved
A space containing propulsion machinery must be equipped with a fixed gas fire extinguishing system. The indicator light for the pre-engineered fixed gas fire extinguishing system shows the system has been discharged. Determine and address the cause of the illuminated discharge light. Demonstrate proper system operation to satisfaction of marine inspector.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 September 2023
Resolved
Pre-engineered fixed gas fire extinguishing systems must be capable of manual actuation from outside the space. The disabling pin for manual activation cable found installed at the cylinder end within the space being protected, preventing manual activation of the system from outside of the space. Remove disabling pin. Demonstrate proper system operation to satisfaction of marine inspector.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 September 2023
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have a means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. Unable to test the function of the installed reset device due to system condition. Demonstrate proper operation of the vessel’s fixed gas fire extinguishing system automatic shutdown and reset device in the attendance of a marine inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 September 2023
Resolved
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. Hull penetration in the forward starboard bilge of the engine room has a valve installed but no actuation handle. Install means to secure valve.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 20 September 2023
Resolved
Each small battery installation must be located in a well-ventilated space and protected from falling objects. Both battery boxes were found with no terminal protection from falling objects. Additionally, electrical components and debris was found stored on top of the aft battery near the battery posts. Provide a means of protection from falling objects and remove stored components and debris from the battery box.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 20 September 2023
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Guards are not installed over the main engine’s rotating machinery and belts. Install suitable guards.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 20 September 2023
Resolved
Each life float must be fitted with a light. The light on the vessel’s starboard life float was found to be non-operational. Provide an operational light for the starboard life float.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 October 2022
Resolved
Missing Crew training records/logs. Must show proof of crew training for each Captain and Mate prior to carrying passengers.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 October 2022
Resolved
Missing logs for fire, MOB and abandon ship drills. Must provide proof of crew completely all drills prior to carrying passengers.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 October 2022
Resolved
Vessel had 4 valid red flares and 4 expired flares. Vessel is required to have 12 flares onboard. Must replace missing 8 flares prior to carrying passengers.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 October 2022
Resolved
Anchor/all around light, is mounted at the operating station under the canopy and light was not working. Must move anchor light to the highest point of the vessel so it can be seen from every direction. Vessel restricted to daylight hours only.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2022
Resolved
Life ring floating light was not onboard the vessel and not working. Must make repairs and place onboard the vessel. Vessel restricted to daylight hours only.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2022
Resolved
Life ring had a few tears into the foam, grab line was dry rotted and ring was faded. Must make repairs or replace life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2022
Resolved
Missing Coast Guard approved Nav Chart. Must have updated Nav chart onboard or have GPS updated with latest Nav Chart.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 October 2022
Resolved
Both life floats are fadded and need repainting. Must repaint both life floats.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 October 2022
Resolved
Missing logs for monthly EPRIB test Must provide proof for testing EPRIB monthly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 July 2021
Resolved
MDE was overhauled and need to conduct engine test. There was no sensor for oil psi. Make repairs and conduct test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 July 2021
Resolved
MDE engine was overhauled and must conduct successful sea trials prior to carrying passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 July 2021
Resolved
Both automatic bilge pumps indicators at helm station were not working. Must make repairs and test to the satisfaction of attending CG Marine Inspector
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 7 July 2021
Resolved
Engine room ventilation does not close all the way. Must make repairs and test to satisfaction of attending CG Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 7 July 2021
Resolved
MDE guard was missing. Must have guard around all rotating machinery to prevent injury. Replace missing guard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2021
Resolved
Engineroom was found with a lot of loose dead end wires hanging. Either connect all wires or pull out all dead end wires.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2021
Resolved
Most of the wiring in the engineroom were not supported and hanging down. Wiring must be supported with metal brackets at least every 24 inches.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 July 2021
Resolved
Life jacket stowage needs re labeling and with correct qty.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 July 2021
Resolved
All 4 life float paddles needs vessel's name written on them.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 July 2021
Resolved
2 adult life jackets needs repair. Passenger count reduced by 2 until repaired or replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 July 2021
Resolved
Life jacket doning placard was missing. Must replace.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 July 2021
Resolved
Emergency fuel shut off valves needs labeling.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 7 July 2021
Resolved
Un able to conduct fire and MOB drills due to condition of vessel. Must conduct drills prior to carrying passengers.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 May 2021
Resolved
EPIRB registratation and battery expired Sept 2020. Must register EPIRB and install new battery. Vessel is restricted to 3 miles from shore.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 April 2021
Resolved
Vessel was found operating illegally with passengers with out a valid COI. Must conduct a COI inspection and issue a COI prior to carrying passengers.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 May 2020
Resolved
FCC documentation missing for vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 May 2020
Resolved
Lifefloats were severely faded and retroreflective tape was no longer servicable. Repair/replace lifefloats.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 May 2020
Resolved
Lifefloats are not connected to vessel via the weak link. Install painter/weak link to vessel in accordance with regulations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 May 2020
Resolved
Alarms for both the high water and automatic bilge pump are not properly labeled and are not properly functioning. Repair and relabel all bilge pumping and alarm arrangements.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 May 2020
Resolved
Vessel through hulls and starboard fuel tank are not properly grounded. Ensure all required components of vessel are properly grounded to prevent accelerated corrosion.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 26 May 2020
Resolved
Vessel is in the process of replacing VHF radio. Ensure radio installation is completed in accordance with regulations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 May 2020
Resolved
Vessel has multiple dead end wires located in the engine space. Remove all wiring that is not currently being utilized by the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 May 2020
Resolved
Lifering found to be unservicable. Operator replaced life ring prior to departure of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2020
Resolved
07 lifejacket light batteries were dead. Batteries replaced on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 May 2020
Resolved
Fireboy system was not serviced. Ensure system is serviced. Following servicing a test of the machinery shutdowns and override function must be successfully completed in the presence of a marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 May 2020
Resolved
Man Overboard Drill must be successfully completed in the presence of a marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 February 2020
Resolved
Replace and/or sister the damaged 4th and 5th stringers from aft on starboard side with materials to meet the structural strength requirements of the original materials from the approved hull plans.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 February 2020
Resolved
Cap all through hulls not in use
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2020
Resolved
Properly secure port fuel tank
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 February 2020
Resolved
Secure all engine room penetrations, make watertight
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 February 2020
Resolved
Replace cut grounding wires.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 February 2020
Resolved
Replace/re attach engine room insulation
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 26 February 2020
Resolved
Properly reinstall hand rail on starboard side
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 March 2019
Resolved
Provide closure devices for engine room ventilation on Port and STBD sides. Devices must be readily available and mounted in the vicinity of the vents. Temporary means provided (foam cutouts).
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 12 March 2019
Resolved
Recovery ladder for Man overboard shall be provided with means to prevent shifting and grab handles. Ladder shall have means to decrease angle of vertical position for crew safety.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 12 March 2019
Resolved
Provide documentation of Drug Testing Consortium for all crew to include background checks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 March 2019
Resolved
For the purpose of flexibility only, flexible hose installed in lengths of not more than 760 millimeters (30 inches) and subject to pressures of not more than 35 kPa (5 psig). Vessel replaced all original hard lines with all flexible lines.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 7 March 2019
Resolved
Overboard discharge valve seized. All valves must be operational.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 March 2019
Resolved
Through hull penetrations must be grounded. No grounding provided for through hulls in the lazaret(rudder, raw water)
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 March 2019
Resolved
High water alarms and automatic bilge pumps are not audible and visual at the operating station. Port side bilge pump not connected.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 March 2019
Resolved
Through hull penetrations between engine space and lazaret are not watertight or vapor tight.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 March 2019
Resolved
Oil pump must be hard wired. Alligator clamps are not authorized.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 March 2019
Resolved
All cable and wire must be UL boat or marine grade wire. No dead end wires are permitted. Ensure all electrical installations are made in accordance with either 46 CFR 183 or ABYC.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 March 2019
Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 March 2019
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 March 2019
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 March 2019
Resolved
A hatch exposed to the weather must be watertight. Engine room hatch missing latch on one end.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 March 2019
Resolved
Post all pages of the COI and Stability letter.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 March 2019
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Waterlight must be connected by a lanyard via a detachable clip.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 March 2019
Resolved
Life floats need to be outfitted IAW 46 CFR 160.027. Arrange the painters, pendanats, paddles, waterlights IAW the e above. Life float must be international orange.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 March 2019
Resolved
Post life jacket donning placards for all types of life jackets on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 March 2019
Resolved
Post SPV decal.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 March 2019
Resolved
Vessel must have life jackets on board for all passengers. 01 child life jacket condemned. Replace SOLAS tape on 01 adult life jacket.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 March 2019
Resolved
Must have either 6 red and 6 orange flares or 12 red flares. Vessel missing 4 flares.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 7 March 2019
Resolved
EPIRB must be located clear of all obstructions. Mount in a float free location.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 7 March 2019
Resolved
Provide light for magnetic compass.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 7 March 2019
Resolved
Vessel VHF radio must have GPS input provided.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 7 March 2019
Resolved
Vessel must have single side band radio installed and operational per FCC requirements. Route restricted to 20NM.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 March 2019
Resolved
Vessel all around white light not operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2019
Resolved
Conduct underway drills with Marine Inspectors in attendance.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 March 2019
Resolved
Demonstrate proper operation of pre-engineered fire extinguishing system.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 11 December 2017
Resolved
FWD bilge high level alarm visual indicator is extinguished. Repair/renew.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 December 2017
Resolved
All strobes have incorrect batteries, and will not float. Renew batteries and prove proper operation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 December 2017
Resolved
BII fire extinguisher is not mounted in the correct bracket and will not stay in place. Provide and mount correct bracket.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 11 December 2017
Resolved
Compass light is extinguished. Repair/renew.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 December 2017
Resolved
All nautical charts and publications are out of dat. Renew.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2017
Resolved
First aid kit is missing contents. Renew contents per CFR.
Electrical › Electric Supply System (service) › Cable
Issued 11 January 2017
Resolved
Positive cable from battery to starter is smashed and has missing insulation. Replace/repair.
Engineering › Fuel Oil Service System › Suction Strainer
Issued 11 January 2017
Resolved
RACOR filter is missing a flame bowl repair/replace.
Lifesaving › Lifefloat › Retroreflective Material
Issued 11 January 2017
Resolved
Life float reflective tape is wasted and must be replaced.
Lifesaving › Lifebuoys › Size
Issued 11 January 2017
Resolved
Life ring is incorrect size. Provide 24" life ring.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 11 January 2017
Resolved
Vessel was missing 1 B-II fire extinguisher.
Fire Fighting › Fire Bucket › Capacity
Issued 11 January 2017
Resolved
Vessel did not have any 2.5 gallon fire buckets.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Determination of Alcohol/Drug Use
Issued 11 January 2017
Resolved
Vessel had expired alcohol test strips.
Engineering › Fuel Oil Service System › Filter
Issued 24 January 2012
Resolved
Racor fuel filter has plastic bowl without flame shield, install plastic bowl with approved flame shield or install metal bowl.
Engineering › Fuel Oil Service System › Piping
Issued 24 January 2012
Resolved
Fuel line from fuel tank to fuel filter is not CG approved for commercial vessels. Provide approved fuel hose as per 46 CFR 182.720 (SAE standard J-1475, or metal pipe in accordance with 46 CFR 182.455.
Stability › Watertight Integrity › General
Issued 24 January 2012
Resolved
Provide tether line on all hatches to attach hatch to vessel, to prevent lose of hatch overboard.
Lifesaving › Lifefloat › Float Free
Issued 24 January 2012
Resolved
Both 6 man Lifefloats are not float free, and they do not have a painter attached to a weak link. Install 100 foot painter line with weak link installed. Mount Lifefloats in a float free arrangement.
Lifesaving › Lifefloat › Float-free Link
Issued 24 January 2012
Resolved
Both Lifefloat weak links are missing, vessel is restricted to operations in less than 100 feet of water.
Communications › Radio Communications › EPIRB
Issued 9 March 2010
Resolved
EPIRB Hydrostatic release is out of date. Install new hydro release.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 March 2010
Resolved
First aid kit does not have all the required items. Provide first aid kit as required in 46 CFR 184.710.
Communications › Radio Communications › EPIRB
Issued 9 March 2010
Resolved
Epirb hydrostatic release past due date of Jan. 2010. Renew hydro release.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 March 2010
Resolved
First aid kit missing required items. Provide all required items as per 46 CFR 184.710.
Stability › Watertight Integrity › General
Issued 8 January 2010
Resolved
Replace two broken latches on deck hatches.
Stability › Watertight Integrity › General
Issued 8 January 2010
Resolved
Missing sea valve on live well tank drain, this drain penetrates thru the hull near the waterline on the transom. Install positive closing valve as close to the hull as possible.
Engineering › Fuel Oil Service System › Filter
Issued 8 January 2010
Resolved
Racor filter needs a flame bowl (shield) installed. Provide new flame bowl and install per manufactures instruction.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 January 2010
Resolved
Shafts and propellers were not installed at time of inspection, make vessel available for examination after they are installed.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 28 December 2007
Resolved
Provide a MF radio IAW 47 CFR 80.905. Vessel restricited to 20 nm until corrected.
Casualty record · 3
14 May 2009Routine · role: Involved in a Marine Casualty · activity 3474962
30 October 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4744684
22 February 2022Routine · role: Involved in a Marine Casualty · 1 injured · activity 7400163
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.