11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 February 2025
Resolved
Renew faded retro on both life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 February 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 February 2025
Resolved
Replace rusted out motor mounts.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2024
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil that might create a fire hazard or clog bilge pumping systems. Leaking fuel oil was found in the bilges on during a Living Marine Resources boarding on 10APR24. After actions were taken to attempt to rectify that but failed, leaking fuel oil, both atomized and liquid, was again identified during an inspection on 19APR24, creating both pollution and fire hazards.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2024
Resolved 24 April 2024
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 19 April 2024
Resolved
The vessel BARRACUDA is a SPV-T, therefore not required
a safety management system (SMS) per regulation. Sector
Key West has found the below deficiencies, in addition to the recently issued code 17c deficiencies on 11APR24(see MISLE activity 7898338) and 14APR24 (the instigating action for this inspection), to be
objective evidence that a serious substandard condition
has not been pro-actively managed by the vessel's owner/
operator, leading to a lack of safety culture on board
the vessel.
Condition: Invalid
Action required: 30 - Ship detained
Due 19 April 2024
Resolved 24 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 April 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel suffered propulsion system failure while underway requiring towing back to mooring. Determine cause of failure and make repairs to the satisfaction of the attending marine inspector.
Action required: 30 - Ship detained
Due 14 April 2024
Resolved 24 April 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 April 2024
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, or debris, or other matter that might create a fire hazard or clog bilge pumping systems. Accumulation of oil found in engine room bilge with absorbent cloths. Remove oil and cloths, determine sources of leak and make repairs to the satisfaction of attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2024
Resolved 11 April 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 11 April 2024
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not coverd by standards in this subchpater may be inspected in accordance with sandards acceptable to the cognizant OCMI as good marine practice. Main propulsion engine's shaft penetration was found to be leaking sea water at a steady stream into the bilge. Make adjustment or repairs to the main propulsion engine's shaft seal to the satisfaction of the attedning marine inspector. Corrected on the spot.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2024
Resolved 11 April 2024
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 11 April 2024
Resolved
Each small battery installation must be located in a well-ventilated space and protected from falling objects. Both battery boxes were found with no terminal protection from falling objects. proveide a means of protection from falling objects and remvoe stored compoennts and debris from the falling battery box to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2024
Resolved 11 April 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 November 2023
Resolved
Anchor light does not work and also is not mounted in a location that can be seen from 360 degrees. Must make repairs to anchor light and move to top of vessel where it can be seen from all around.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 November 2023
Resolved
Fuel supply and return hoses do not meet the SAE J1942 standard. Must replace both hoses that meet the requirements for CG approved SAE J1942.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 November 2023
Resolved 14 November 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 November 2023
Resolved
Two stanchions on the aft railing are broken. Replace both stanchions.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 November 2023
Resolved 14 November 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 September 2023
Resolved
The vessel BARRACUDA is a SPV-T, therefore not required
a safety management system (SMS) per regulation. Sector
Key West has found the below deficiencies to be
objective evidence that a serious substandard condition
has not been pro-actively managed by the vessel's owner/
operator, leading to a lack of safety culture on board
the vessel.
Condition: Damaged By Earlier Event
Action required: 25 - Ship denied entry
Due 21 September 2023
Resolved 14 November 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. New fuel supply piping was installed without notifying the cognizant OCMI.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 14 November 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 September 2023
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard or clog bilge pumping systems. Approximately 03 gallons of hydraulic fluid were found in the forward part of the lazarette bilge. Remove hydraulic fluid accumulation from the lazarette bilge. Identify source and make repairs.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 7 November 2023
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 September 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected, and all required guards and protective devices must be in satisfactory condition. The following fire hazards were identified in the vessel’s main machinery space and shall be resolved to the satisfaction of the of the attending marine inspector:
1. The bilge was found to have super saturated oil soaked absorbent pads located under the main propulsion engine. Remove oil-soaked absorbent pads and all oil residue from the bilge.
2. An open lid bucket with approximately 02 gallons of diesel fuel on the port side of the main engine was present. Remove hazard.
3. Numerous bottles of compressed flammable materials were stored throughout the engine space. Remove hazard.
4. The main propulsion engine’s crank case vent was found to be improperly installed and venting directly onto the engine’s main air intake filter resulting in filter oil saturation. Properly install the main propulsion engine’s crank case vent.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 7 November 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 September 2023
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment,
materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Main propulsion engine’s shaft penetration was found to be leaking sea water at a steady stream into the bilge. Make adjustment or repairs to the main propulsion engine’s shaft seal.
Condition: Design Flaw
Action required: 30 - Ship detained
Resolved 7 November 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to prevent electrical ignition of flammable vapors. Battery system terminal board found mounted directly to the main engine’s metallic fuel supply line. Remove terminal board from its current location and install in a suitable location.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 7 November 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2023
Resolved
All cable and wire must be protected by metal coverings or other suitable means if in areas subject to mechanical abuse. The positive cable for the main engine’s starting system was found to be pinched between deck grating and the hull and installed without protection across a stepway near the front of the engine. Install protection on the main engine’s positive starting cable.
Condition: Design Flaw
Action required: 30 - Ship detained
Resolved 7 November 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2023
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Multiple exposed electrical wire connections found in underneath the main engine, in the overhead in the port aft section of the engine room and in the starboard overhead of the lazarette. Place all connections within a suitable enclosure.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 7 November 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2023
Resolved
Nonmetallic piping must not be used in gasoline or diesel fuel systems unless they meet SAE J1942 and J1475 specifications. Flexible fuel hose installed for the main engine fuel supply line does not meet SAE J1942 and J1475 specifications standards. Replace fuel supply line with materials meeting required standards.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 14 November 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The vessel’s port fuel tank located in the lazarette was found to have an inoperable shutoff valve installed. Repair or replace the inoperable fuel shutoff valve.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 7 November 2023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 September 2023
Resolved
A space containing propulsion machinery must be equipped with a fixed gas fire extinguishing system. The indicator light for the pre-engineered fixed gas fire extinguishing system shows the system has been discharged. Determine and address the cause of the illuminated discharge light. Demonstrate proper system operation to satisfaction of marine inspector.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 7 November 2023
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 September 2023
Resolved
Pre-engineered fixed gas fire extinguishing systems must be capable of manual actuation from outside the space. The disabling pin for manual activation cable found installed at the cylinder end within the space being protected, preventing manual activation of the system from outside of the space. Remove disabling pin. Demonstrate proper system operation to satisfaction of marine inspector.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 7 November 2023
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 September 2023
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have a means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. Unable to test the function of the installed reset device due to system condition. Demonstrate proper operation of the vessel’s fixed gas fire extinguishing system automatic shutdown and reset device in the attendance of a marine inspector.
Action required: 30 - Ship detained
Resolved 7 November 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 September 2023
Resolved
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. Hull penetration in the forward starboard bilge of the engine room has a valve installed but no actuation handle. Install means to secure valve.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 7 November 2023
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 20 September 2023
Resolved
Each small battery installation must be located in a well-ventilated space and protected from falling objects. Both battery boxes were found with no terminal protection from falling objects. Additionally, electrical components and debris was found stored on top of the aft battery near the battery posts. Provide a means of protection from falling objects and remove stored components and debris from the battery box.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 7 November 2023
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 20 September 2023
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Guards are not installed over the main engine’s rotating machinery and belts. Install suitable guards.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 November 2023
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 20 September 2023
Resolved
Each life float must be fitted with a light. The light on the vessel’s starboard life float was found to be non-operational. Provide an operational light for the starboard life float.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 November 2023
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 October 2022
Resolved
Missing Crew training records/logs. Must show proof of crew training for each Captain and Mate prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2022
Resolution: Sent pictures of crew training logs.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 October 2022
Resolved
Missing logs for fire, MOB and abandon ship drills. Must provide proof of crew completely all drills prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2022
Resolution: Sent pictures of all logs.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 October 2022
Resolved
Vessel had 4 valid red flares and 4 expired flares. Vessel is required to have 12 flares onboard. Must replace missing 8 flares prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2022
Resolution: Bought 8 new red flares for a total of 12. All SAT
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 October 2022
Resolved
Anchor/all around light, is mounted at the operating station under the canopy and light was not working. Must move anchor light to the highest point of the vessel so it can be seen from every direction. Vessel restricted to daylight hours only.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2022
Resolved 28 October 2022
Resolution: Anchor light was re located to top/aft canopy. Test SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2022
Resolved
Life ring floating light was not onboard the vessel and not working. Must make repairs and place onboard the vessel. Vessel restricted to daylight hours only.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2022
Resolved 28 October 2022
Resolution: Light onboard and tested SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2022
Resolved
Life ring had a few tears into the foam, grab line was dry rotted and ring was faded. Must make repairs or replace life ring.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2022
Resolved 28 October 2022
Resolution: New Life ring on board
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2022
Resolved
Missing Coast Guard approved Nav Chart. Must have updated Nav chart onboard or have GPS updated with latest Nav Chart.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2022
Resolved 4 January 2023
Resolution: New Nav chart onboard
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 October 2022
Resolved
Both life floats are fadded and need repainting. Must repaint both life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2022
Resolved 28 October 2022
Resolution: Repainted both life floats
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 October 2022
Resolved
Missing logs for monthly EPRIB test Must provide proof for testing EPRIB monthly.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2022
Resolved 28 October 2022
Resolution: Logs showing monthly EPRIB test
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 July 2021
Resolved
MDE was overhauled and need to conduct engine test. There was no sensor for oil psi. Make repairs and conduct test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 July 2021
Resolved 16 July 2021
Resolution: Conducted satisfactory alarm test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 July 2021
Resolved
MDE engine was overhauled and must conduct successful sea trials prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 7 July 2021
Resolved 16 July 2021
Resolution: Conducted satisfactory sea trials
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 July 2021
Resolved
Both automatic bilge pumps indicators at helm station were not working. Must make repairs and test to the satisfaction of attending CG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2021
Resolved 22 September 2021
Resolution: Replaced connections and light bulbs. Test SAT
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 7 July 2021
Resolved
Engine room ventilation does not close all the way. Must make repairs and test to satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 July 2021
Resolved 12 July 2021
Resolution: Added a latch to secure ventilation door. Test SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 7 July 2021
Resolved
MDE guard was missing. Must have guard around all rotating machinery to prevent injury. Replace missing guard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2021
Resolved 12 July 2021
Resolution: Added guard in front of engine.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2021
Resolved
Engineroom was found with a lot of loose dead end wires hanging. Either connect all wires or pull out all dead end wires.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2021
Resolved 18 August 2021
Resolution: All dead end wires were pulled and all wires in engine room were secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2021
Resolved
Most of the wiring in the engineroom were not supported and hanging down. Wiring must be supported with metal brackets at least every 24 inches.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2021
Resolved 18 August 2021
Resolution: All engineroom wires were supports in accordance with ABYC standards
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 July 2021
Resolved
Life jacket stowage needs re labeling and with correct qty.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2021
Resolved 10 August 2021
Resolution: Owner/ Operator submitted photographic imagery of labeling of lifejacket stowage, with accurate count of both sizes.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 July 2021
Resolved
All 4 life float paddles needs vessel's name written on them.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2021
Resolved 10 August 2021
Resolution: Owner/ Operator submitted photographic imagery of labeling of lifefloat paddles with vessel's name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 July 2021
Resolved
2 adult life jackets needs repair. Passenger count reduced by 2 until repaired or replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2021
Resolved 5 August 2021
Resolution: Operator provided photographic imagery 02 recently acquired lifejackets, increasing the passenger count to original count.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 July 2021
Resolved
Life jacket doning placard was missing. Must replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2021
Resolved 10 August 2021
Resolution: Owner/ Operator submitted photographic imagery of newly posted lifejacket donning instructions.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 July 2021
Resolved
Emergency fuel shut off valves needs labeling.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2021
Resolved 12 July 2021
Resolution: Emergency fuel shut off valves were labeled correctly.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 7 July 2021
Resolved
Un able to conduct fire and MOB drills due to condition of vessel. Must conduct drills prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 July 2021
Resolved 16 July 2021
Resolution: Conducted satisfactory MOB and fire drills.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 May 2021
Resolved
EPIRB registratation and battery expired Sept 2020. Must register EPIRB and install new battery. Vessel is restricted to 3 miles from shore.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2021
Resolved 6 August 2021
Resolution: Operator submitted photographic imagery of EPIRB renewed registration, battery replacement service and testing. Three mile operating restriction removed, vessel may resume operating beyond three miles.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 April 2021
Resolved
Vessel was found operating illegally with passengers with out a valid COI. Must conduct a COI inspection and issue a COI prior to carrying passengers.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2021
Resolved 16 July 2021
Resolution: Cleared all no sail 835's and issued COI. Vessel is allowed to operate.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 May 2020
Resolved
FCC documentation missing for vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2020
Resolved 16 July 2021
Resolution: FCC Station License and Safety cert were issued to vessel
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 May 2020
Resolved
Lifefloats were severely faded and retroreflective tape was no longer servicable. Repair/replace lifefloats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2020
Resolved 16 July 2021
Resolution: Repairs, repaint and all new SOLAS retro tape replaced
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 May 2020
Resolved
Lifefloats are not connected to vessel via the weak link. Install painter/weak link to vessel in accordance with regulations.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2020
Resolved 16 July 2021
Resolution: Weak link installed properly, 1 for both life floats
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 May 2020
Resolved
Alarms for both the high water and automatic bilge pump are not properly labeled and are not properly functioning. Repair and relabel all bilge pumping and alarm arrangements.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2020
Resolved 16 July 2021
Resolution: New high water alarms intalled, tested SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 May 2020
Resolved
Vessel through hulls and starboard fuel tank are not properly grounded. Ensure all required components of vessel are properly grounded to prevent accelerated corrosion.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2020
Resolved 16 July 2021
Resolution: A lot of old wiring was pulled out of boat, rest of wiring was support in accordance with ABYC standards
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 26 May 2020
Resolved
Vessel is in the process of replacing VHF radio. Ensure radio installation is completed in accordance with regulations.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2020
Resolved 16 July 2021
Resolution: VHR radio installed, MMSI number updated, FCC safety cert issued, tested SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 May 2020
Resolved
Vessel has multiple dead end wires located in the engine space. Remove all wiring that is not currently being utilized by the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2020
Resolved 16 July 2021
Resolution: Old wiring pulled out of vessel, fuel tank properly grounded, wires supported in accordance with ABYC standards.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 May 2020
Resolved
Lifering found to be unservicable. Operator replaced life ring prior to departure of MI.
Action required: 10 - Deficiency Rectified
Due 26 May 2020
Resolved 26 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2020
Resolved
07 lifejacket light batteries were dead. Batteries replaced on the spot.
Action required: 10 - Deficiency Rectified
Due 26 May 2020
Resolved 26 May 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 May 2020
Resolved
Fireboy system was not serviced. Ensure system is serviced. Following servicing a test of the machinery shutdowns and override function must be successfully completed in the presence of a marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2020
Resolved 16 July 2021
Resolution: Fireboy system was serviced and tested SAT
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 May 2020
Resolved
Man Overboard Drill must be successfully completed in the presence of a marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2020
Resolved 16 July 2021
Resolution: MOB and Fire drills were completed, SAT
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 February 2020
Resolved
Replace and/or sister the damaged 4th and 5th stringers from aft on starboard side with materials to meet the structural strength requirements of the original materials from the approved hull plans.
Action required: 705 - Other - as specified
Resolved 4 April 2020
Resolution: Vessel sent pictures detailing repairs made to stringers.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 February 2020
Resolved
Cap all through hulls not in use
Action required: 705 - Other - as specified
Resolved 4 April 2020
Resolution: Vessel sent picture to unit showing rectification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2020
Resolved
Properly secure port fuel tank
Action required: 705 - Other - as specified
Due 4 April 2020
Resolved 4 April 2020
Resolution: Vessel sent pictures to OCMI verifying repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 February 2020
Resolved
Secure all engine room penetrations, make watertight
Action required: 705 - Other - as specified
Resolved 4 April 2020
Resolution: Vessel sent pictures to OCMI verifying repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 February 2020
Resolved
Replace cut grounding wires.
Action required: 705 - Other - as specified
Resolved 4 April 2020
Resolution: Operator sent pictures to OCMI verifying grounding wire repairs.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 February 2020
Resolved
Replace/re attach engine room insulation
Action required: 705 - Other - as specified
Resolved 4 April 2020
Resolution: Operator sent pictures to OCMI verifying repairs to insulation.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 26 February 2020
Resolved
Properly reinstall hand rail on starboard side
Action required: 705 - Other - as specified
Resolved 4 April 2020
Resolution: Hand rail repaired and verified with photograph.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 March 2019
Resolved
Provide closure devices for engine room ventilation on Port and STBD sides. Devices must be readily available and mounted in the vicinity of the vents. Temporary means provided (foam cutouts).
Action required: 705 - Other - as specified
Due 15 March 2019
Resolved 18 March 2019
Resolution: Semi-permanent closures in place, vessel will be fitted permanently in coming months.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 12 March 2019
Resolved
Recovery ladder for Man overboard shall be provided with means to prevent shifting and grab handles. Ladder shall have means to decrease angle of vertical position for crew safety.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2019
Resolution: Life sling provided to vessel for MOB recovery.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 12 March 2019
Resolved
Provide documentation of Drug Testing Consortium for all crew to include background checks.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2019
Resolution: Documentation provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 March 2019
Resolved
For the purpose of flexibility only, flexible hose installed in lengths of not more than 760 millimeters (30 inches) and subject to pressures of not more than 35 kPa (5 psig). Vessel replaced all original hard lines with all flexible lines.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 March 2019
Resolution: replaced with fixed copper tubing- sending lines
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 7 March 2019
Resolved
Overboard discharge valve seized. All valves must be operational.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 March 2019
Resolution: valve operational
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 March 2019
Resolved
Through hull penetrations must be grounded. No grounding provided for through hulls in the lazaret(rudder, raw water)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 March 2019
Resolution: through hulls all grounded
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 March 2019
Resolved
High water alarms and automatic bilge pumps are not audible and visual at the operating station. Port side bilge pump not connected.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 March 2019
Resolution: bilge pumps operational
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 March 2019
Resolved
Through hull penetrations between engine space and lazaret are not watertight or vapor tight.
Action required: 705 - Other - as specified
Resolved 20 March 2019
Resolution: All bulkhead penetrations are vapor tight, expanding foam applied.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 March 2019
Resolved
Oil pump must be hard wired. Alligator clamps are not authorized.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: oil pump hard wired
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 March 2019
Resolved
All cable and wire must be UL boat or marine grade wire. No dead end wires are permitted. Ensure all electrical installations are made in accordance with either 46 CFR 183 or ABYC.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2019
Resolution: All wire in accordance with 46 CFR 183.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 March 2019
Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: batteries installed correctly
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 March 2019
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: guards were installed
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 March 2019
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 March 2019
Resolution: marked vessel name and hailing port on vessel
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 March 2019
Resolved
A hatch exposed to the weather must be watertight. Engine room hatch missing latch on one end.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2019
Resolution: Hatch latches repaired and replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 March 2019
Resolved
Post all pages of the COI and Stability letter.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 March 2019
Resolution: posted COI and stability letter
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 March 2019
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Waterlight must be connected by a lanyard via a detachable clip.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 March 2019
Resolution: ring life bouy installed and in proper condition
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 March 2019
Resolved
Life floats need to be outfitted IAW 46 CFR 160.027. Arrange the painters, pendanats, paddles, waterlights IAW the e above. Life float must be international orange.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 March 2019
Resolution: life float installed properly
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 March 2019
Resolved
Post life jacket donning placards for all types of life jackets on board.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 March 2019
Resolution: posted all signs
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 March 2019
Resolved
Post SPV decal.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: posted SPV Decal
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 March 2019
Resolved
Vessel must have life jackets on board for all passengers. 01 child life jacket condemned. Replace SOLAS tape on 01 adult life jacket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2019
Resolution: all life jackets on board
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 March 2019
Resolved
Must have either 6 red and 6 orange flares or 12 red flares. Vessel missing 4 flares.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 March 2019
Resolution: vessel had all required flares
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 7 March 2019
Resolved
EPIRB must be located clear of all obstructions. Mount in a float free location.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 March 2019
Resolution: EPIRB mounted in a float free location
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 7 March 2019
Resolved
Provide light for magnetic compass.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: light on compass works
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 7 March 2019
Resolved
Vessel VHF radio must have GPS input provided.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 March 2019
Resolution: vhf radio had gps input
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 7 March 2019
Resolved
Vessel must have single side band radio installed and operational per FCC requirements. Route restricted to 20NM.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 April 2019
Resolution: Vessels route reduced to 20 miles, new COI issued.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 March 2019
Resolved
Vessel all around white light not operational.
Action required: 705 - Other - as specified
Resolved 12 March 2019
Resolution: Light operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2019
Resolved
Conduct underway drills with Marine Inspectors in attendance.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 March 2019
Resolution: conducted drills
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 March 2019
Resolved
Demonstrate proper operation of pre-engineered fire extinguishing system.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 March 2019
Resolution: demonstrated proper operation of pre-engineered fire extinguishing system
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 11 December 2017
Resolved
FWD bilge high level alarm visual indicator is extinguished. Repair/renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2017
Resolved 5 January 2018
Resolution: New bulb was installed and tested all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 December 2017
Resolved
All strobes have incorrect batteries, and will not float. Renew batteries and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2017
Resolved 5 January 2018
Resolution: New strobe batteries were installed and tested all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 December 2017
Resolved
BII fire extinguisher is not mounted in the correct bracket and will not stay in place. Provide and mount correct bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2017
Resolved 5 January 2018
Resolution: Correct new bracket was mounted.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 11 December 2017
Resolved
Compass light is extinguished. Repair/renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2017
Resolved 5 January 2018
Resolution: New compass was installed and tested all sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 December 2017
Resolved
All nautical charts and publications are out of dat. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2017
Resolved 5 January 2018
Resolution: All navigation publications and charts were renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2017
Resolved
First aid kit is missing contents. Renew contents per CFR.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2017
Resolved 5 January 2018
Resolution: New approved first aid kit was provided.
Electrical › Electric Supply System (service) › Cable
Issued 11 January 2017
Resolved
Positive cable from battery to starter is smashed and has missing insulation. Replace/repair.
Action required: 705 - Other - as specified
Due 18 January 2017
Resolved 12 January 2017
Resolution: New cable was installed.
Engineering › Fuel Oil Service System › Suction Strainer
Issued 11 January 2017
Resolved
RACOR filter is missing a flame bowl repair/replace.
Action required: 705 - Other - as specified
Due 18 January 2017
Resolved 25 January 2017
Resolution: New bowl was installed.
Lifesaving › Lifefloat › Retroreflective Material
Issued 11 January 2017
Resolved
Life float reflective tape is wasted and must be replaced.
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 25 January 2017
Resolution: New tape was installed.
Lifesaving › Lifebuoys › Size
Issued 11 January 2017
Resolved
Life ring is incorrect size. Provide 24" life ring.
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 12 January 2017
Resolution: New life ring was provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 11 January 2017
Resolved
Vessel was missing 1 B-II fire extinguisher.
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 12 January 2017
Resolution: New fire extinguisher was provided and installed.
Fire Fighting › Fire Bucket › Capacity
Issued 11 January 2017
Resolved
Vessel did not have any 2.5 gallon fire buckets.
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 25 January 2017
Resolution: Buckets were provided and marked.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Determination of Alcohol/Drug Use
Issued 11 January 2017
Resolved
Vessel had expired alcohol test strips.
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 25 January 2017
Resolution: New alcohol tests were provided and will be maintained onboard.