CENTURION is a 2005 freight ship. The Coast Guard has recorded 14 inspections since 2007, most recently in August 2019, along with 4 deficiencies and 2 operational controls.

Records from 2007 to 2019. Most recent: inspection, 21 August 2019.

Built
2005
Last inspected
21 August 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9304174 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
866508
Flag
MARSHALL ISLANDS
—
Maury page id
psix-866508

Inspections, by type

…with no type recorded6
Years with a record 7 calendar years (2007–2019)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it76831 - Dead Weight, Ton
87174 - Displacement, Ton
25440 - Convention (Subpart B), Net Ton
40060 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

21 August 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6784183
11 December 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6047395
18 July 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5944885
21 October 2015 PII Safety Exam · ISPS II Exam · Administrative Inspection · Ballast Water Examination · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5742779
3 October 2014 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4996999
13 February 2011 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3944291
28 November 2008 Ballast Water Examination · MARPOL Annex I Examination · NPV Safety Exam · MARPOL Annex V Examination · ISPS I Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3365974
27 November 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3365975
27 November 2008 Type not recorded
No type recorded · USCGC POMPANO (WPB 87339) · USCG East District (CGD-E) · Activity 3373752
5 June 2008 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3228181
7 January 2008 ISPS I Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3126149
28 December 2007 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3121738
24 December 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3120453
15 October 2007 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3080510

Deficiency record · 4

Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 11 December 2016 Resolved
0936-Stearing Gear-The stearing gear compartment shall be provided with suitable arrangements to ensure working access to stearing gear machinery and controls. Steering compartment was used to store numerous barrels of hydraulic oil without apporiate arrangements. 74SOLAS(cons04)II-I Reg 29.13.2-40ac
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 10 January 2017
Resolved 21 August 2019
Resolution: Attended with vessel's Flag State. Access arrangements are satisfactory.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 11 December 2016 Resolved
2199-Other(Marpol Operation def.)-The type and quanity of chemicals that are required to operate the device including instructions on proper handling,storage, and use of chemicals. Marine Sanatation Device is being operated with chemicals other than those listed in operations manual. 33CFR159.57(a)(5)-40ac
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 10 January 2017
Resolved 21 August 2019
Resolution: Attended with vessel's Flag State. Chemicals found acceptable for the ship'd MSD system.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 21 October 2015 Resolved
AN EMBARKATION LADDER COMPLYING WITH THE REQUIREMENTS OF PARAGRAPH 6.1.6 OF THE CODE EXTENDING, IN A SINGLE LENGTH, FROM THE DECK TO THE WATERLINE IN THE LIGHTEST SEA GOING CONDITIONS OR TRIM OF UP TO 10° AND A LIST OF UP TO 20°EITHER WAY SHALL BE PROVIDED. VESSELS STARBOARD EMBARKATION LADDER IS 4FT ABOVE WATERLINE, FULLY EXTENDED IN LIGHTEST SEAGOING CONDITION WITH 0° LIST.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 October 2015
Resolution: Received class report from Bureau Veritas.
Fire Fighting › Means of Escape › Doorways
Issued 21 October 2015 Resolved
Doors fitted in boundry bulkheads of machynery spaces of category A shall be reasonaly gastight and self closing.Emergency escape door frame in engine room was missing gastight gasket on upper edge.
Condition: Improper/Lack of Maintenance
Due 21 October 2015
Resolved 21 October 2015
Resolution: Corrected on the spot

Ownership record