MAURY USCG vessel records
← All vessels

SALMO SEEKER

SALMO SEEKER is a 2006 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in May 2026, along with 13 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 21 May 2026.

Built
2006
Last inspected
21 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

866866
Flag
UNITED STATES
Maury page id
psix-866866

Documentation record

Tonnage as PSIX records it4 - Simplified, Net Ton
5 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 15

21 May 2026 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8395036
16 June 2025 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8167085
22 April 2024 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7903460
29 March 2023 COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7684861
29 March 2023 COI Inspection · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7845112
22 April 2022 Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7447987
27 April 2021 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7184572
14 April 2021 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7180550
19 March 2020 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6941859
27 June 2019 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6754618
2 May 2019 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6719969
24 April 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6660858
26 February 2018 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6362067
31 January 2017 Hull Examination · Examination of Repairs · Damage Survey
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6088918
6 May 2016 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5864155

Deficiency record · 13

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 June 2025 Resolved
A flammable vapor detection system must provide a visual and audible alarm at the operating station. Flammable vapor detection system is inoperable. Repair or replace the vapor detection system and prove its proper operation. [46 CFR 182.480 (b)]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2025
Resolution: New sensor installed and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 June 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is certified to carry 17 POB, only 16 adult lifejackets on board. Vessel is restricted to carrying no more than 16 POB until missing lifejacket is replaced. [46 CFR 180.71(a)]
Action required: 705 - Other - as specified
Resolved 28 July 2025
Resolution: New PFD ordered and received. Vessel may carry passengers as per COI
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 June 2025 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Connection secured to starboard battery terminal with wing nut. Replace with permanent type connector. [46 CFR 183.350(d)]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2025
Resolved 28 July 2025
Resolution: Proper connections were installed.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 14 April 2021 Resolved
DC01: The master and the crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions are not posted. Post emergency instructions to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2021
Resolved 27 April 2021
Resolution: Received correspondence from the owner indicating that emergency instructions were placed near the operating station in plane view of the public.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 April 2021 Resolved
DC02: A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First-aid kit has expired burn gel, aspirin, and ammonia inhalant. Update first-aid kit to satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2021
Resolved 27 April 2021
Resolution: Marine Inspector received correspondence with evidence indicating expired consumables had been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 April 2019 Resolved
An adult life jacket must be provided for each person carried on board a vessel.The vessel is certificated for 15 passengers, 13 lifejackets were found onboard. Vessel is limited to 12 passengers until three (03) additional lifejackets are placed onboard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2019
Resolved 25 April 2019
Resolution: Received email with proof of purchase of three (03) type I lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 April 2019 Resolved
A vessel must carry one floating water light, unless it is limited to daytime operation. Float light failed to operate during exam. Vessel limited to daytime operation until floating water light can be proven to operate as designed to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2019
Resolved 2 May 2019
Resolution: Received statement from master indicating he changed the battery and the light works as designed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 April 2019 Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. Water light was tied to the ring buoy minus a corrosion-resistant clip. Vessel required to install corrosion-resistant clip to satisfaction of attending Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2019
Resolved 27 June 2019
Resolution: Confirmed with Owner/Operator that a clip was placed into service.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 April 2018 Resolved
Mount fume/vapor detector in engine compartment. (Fume/vapor detector was present, but it was not mounted properly.)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: Vessel owner removed inoperable fume/vapor detector and properly mounted the working fume/vapor detector in the engine compartment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 April 2018 Resolved
Label fuel cut-off valves at the remote pull station (emergency).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: Vessel owner labeled both the port and starboard remote, fuel shut-off valves at the pull station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2018 Resolved
Provide a float-light for the life-ring buoy. (Owner desires to have the option of operating after daylight hours.)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2018
Resolution: Vessel owner purchased and attached a floating water-light to his life-ring buoy.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 April 2018 Resolved
Provided two, 2 1/2 gallon fire-buckets with lanyards.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: Owner provided two, 2 1/2 gallon fire buckets with attached lanyards. Both buckets were properly labeled.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 11 April 2018 Resolved
Provide and post emergency procedures aboard the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2018
Resolution: Vessel owner provided a copy and picture showing the emergency procedures posted on board the vessel.

Ownership record