MAURY USCG vessel records Sign in
← All vessels

SEACOR COLUMBUS

SEACOR COLUMBUS is a 2007 offshore supply vessel. The Coast Guard has recorded 17 inspections since 2006, most recently in May 2023, along with 11 deficiencies and 1 casualty investigation in 2007.

Records from 2006 to 2023. Most recent: inspection, 19 May 2023.

Built
2007
Last inspected
19 May 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9458793 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
867012
Flag
MEXICO
368160000 (licence lapsed)
Maury page id
psix-867012

Inspections, by type

…with no type recorded2
Years with a record 9 calendar years (2006–2023)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1783 - Dead Weight, Metric Ton
2767 - Displacement, Ton
333 - Convention (Subpart B), Net Ton
1111 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDE2494MMSI 368160000 · cancelled · compulsorily equipped · granted 8 December 2007, cancelled 23 April 2014
WDD7901MMSI 368160000 · cancelled · compulsorily equipped · granted 7 June 2007, cancelled 6 December 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 17

19 May 2023 PSC A
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7688647
13 May 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7714171
20 November 2015 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5767326
7 May 2014 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4852429
7 February 2012 MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4227230
19 November 2010 DAPI Audit · MTSA/ISPS Verification · Periodic Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3894850
17 September 2010 Drydock Exam · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3893361
5 December 2009 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3635000
14 February 2009 Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3451815
20 August 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3304194
1 May 2008 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3196638
10 December 2007 Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3110622
20 November 2007 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3114312
15 November 2007 Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3100668
8 November 2007 Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3095400
24 May 2007 Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 2939102
22 May 2006 Initial Certification · Initial Construction-Excluding Oversight · Welding Related Inspections Qualification Testing · Plan Review (Other than "T") · Ballast Water Examination · MARPOL Annex V Examination · Cargo Tank Internal · MARPOL Annex I Examination · MTSA/ISPS Verification · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2931935

Deficiency record · 11

Lifesaving › Lifebuoys › Approval
Issued 7 February 2012 Resolved
Replace stbd forward and stbd aft liferings with CG approved liferings.
Action required: 705 - Other - as specified
Due 7 March 2012
Resolved 22 August 2012
Resolution: USCG approved liferings installed
Lifesaving › Line-Throwing Appliances › Lines
Issued 7 February 2012 Resolved
Provide and stow auxiliary line for line-throwing guns IAW 46 CFR 133.170.
Action required: 705 - Other - as specified
Due 7 March 2012
Resolved 22 August 2012
Resolution: Auxiliary lines provided.
Stability › Watertight Integrity › General
Issued 7 February 2012 Resolved
Replace all watertight door gaskets and adjust all watertight doors. Gaskets used shall not be foam type. This is for all doors below the main deck).
Action required: 705 - Other - as specified
Due 7 March 2012
Resolved 22 August 2012
Resolution: Gaskets replaced and door tested SAT.
Fire Fighting › Fire Main › Pressure
Issued 19 November 2010 Resolved
Bridge fire main pressure gauge is inoperable. Provide guage that displays proper F/M pressure
Due 4 January 2011
Resolved 12 April 2011
Resolution: Received documentation and photograph to satisfy the requirment and clear the deficiency.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 19 November 2010 Resolved
Currently only American crew members are enrolled in a random test program. Bring Drug program into full compliance with 46 CFR 16.
Action required: 705 - Other - as specified
Due 5 December 2012
Resolved 5 December 2012
Resolution: Vessel was given a letter dated 15MAR12 by D.S. [name withheld], Chief Office of Investigations and [name withheld] stating that the current plan aboard the Seacor Columbus is in compliance with all applicable regulations.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 19 November 2010 Resolved
Adjust dogs and replace gaskets on all WTD and hatches as necessary
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2010
Fire Fighting › Fire Pumps › Pressure
Issued 19 November 2010 Resolved
Emergency Fire Pump unable to produce required pressure with two fire nozzles opened.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2010
Electrical › Electrical Distribution System (service) › Switchboard
Issued 19 November 2010 Resolved
Provide technical report to shop proper operation of #2 SSDG reverse power relay
Due 4 January 2011
Resolved 12 April 2011
Resolution: Received third party report noting satisfactory repair and test of RPR.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 11 December 2007 Resolved
Submit non-tank vessel response plan as required by NVIC 01-05 Change 1.
Action required: 705 - Other - as specified
Due 21 February 2008
Resolved 24 March 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 December 2007 Resolved
Submit all revised structural plans for MSC approval.
Action required: 705 - Other - as specified
Due 11 January 2008
Resolved 21 January 2008
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 December 2007 Resolved
Provide USCG approved compass and spare compass as required by SOLAS 74 Consolidated Chapter V, Regulation 19 and 20.
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 21 January 2008

Casualty record · 1

20 November 2007Routine · role: Involved in a Marine Investigation (non-casualty) · 1 injured · activity 3114312
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.