MAURY USCG vessel records Sign in
← All vessels

NYACK BOAT CLUB I

NYACK BOAT CLUB I is a 1980 passenger vessel (uninspected). The Coast Guard has recorded 15 inspections since 2000, most recently in December 2011, along with 29 deficiencies.

Records from 2000 to 2011. Most recent: inspection, 6 December 2011.

Built
1980
Last inspected
6 December 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-8671

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2000–2011)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 15

6 December 2011 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4202741
22 April 2009 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3458001
24 September 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3064703
2 June 2006 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2668563
1 November 2005 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2521955
8 November 2004 MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2236791
22 June 2004 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2106540
18 May 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2071383
28 October 2003 Annual Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1937379
13 November 2002 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1705007
28 June 2002 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1705642
15 October 2001 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1387197
18 July 2001 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1068595
15 June 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1427843
1 June 2000 Initial Certification · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1466698

Deficiency record · 29

Documentation › Certificates/Documents › Stability Letter
Issued 6 December 2011 Resolved
Owner/Operator failed to submit stability certification compliance by 01DEC11. Issued CG-835 reducing maximum persons allowed to 11 based on the assumed average weight per person of 185 pounds and in accordance with 46 CFR 178.320 amended by FR vol. 75, No. 239, USCG-2007-0030. Reduction will remain in effect until Owner/Operator submits stability certification compliance to Coast Guard.
Action required: 705 - Other - as specified
Resolved 5 April 2012
Resolution: Owner/operator submitted a letter requesting the Weight Ratio method to reduce passenger count. Issued an addendum to their Stability Letter showing a reduction in passenger count in compliance with the 185 lb AAWPP.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 22 April 2009 Resolved
Prove proper operation of audible alarm on fireboy system.
Action required: 705 - Other - as specified
Due 22 May 2009
Resolved 27 May 2009
Resolution: Received signed statement that system is properly working.
Construction/Loadline › Hull › Bottom Plating
Issued 20 September 2007 Resolved
Make proper repairs to damages to hull exterior starboard aft.
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 30 April 2008
Resolution: Repairs made.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 20 September 2007 Resolved
Properly mark stowage areas and capacity for child and adult PFDs in accordance with 46 CFR 185.604 (f).
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 30 April 2008
Resolution: Area marked.
Documentation › Markings/Placards › Lifejacket Placard
Issued 20 September 2007 Resolved
Post lifejacket donning placard in accordance with 46 CFR 185.516.
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 30 April 2008
Resolution: Placard posted.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 September 2007 Resolved
Update first aid kit in accordance with 46 CFR 160.041.
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 30 April 2008
Resolution: Kit updated.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 20 September 2007 Resolved
Provide proof of annual servicing of portable and fixed fire extinguishing system.
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 30 April 2008
Resolution: annual servicing completed.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 September 2007 Resolved
Provide portable lighting at operating station in accordance with 46 CFR 183.430.
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 30 April 2008
Resolution: Light installed.
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 20 September 2007 Resolved
Post Emergency Instructions List in accordance with 46 CFR 185.510.
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 30 April 2008
Resolution: Instructions listed.
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 September 2007 Resolved
Provide training log/proof of crew training in accordance with 46 CFR 185.420.
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 30 April 2008
Resolution: Log provided.
Documentation › Logs/Records › Logbook (official)
Issued 20 September 2007 Resolved
Provide plan for maintaining passenger count in accordance with 46 CFR 185.504.
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 30 April 2008
Resolution: Plan provided.
Fire Fighting › Ventilation Systems › Ducts
Issued 20 September 2007 Resolved
Provide means to close engine compartment ventilation in accordance with 46 CFR 182.465.
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 30 April 2008
Resolution: Closure supplied.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 September 2007 Resolved
Make repairs to deck (boarding) railing.
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 30 April 2008
Resolution: Railing repaired.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 September 2007 Resolved
Prove master orientation with operation and testing of Fireboy system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2008
Resolution: Training provided.
Communications › Alarms/Indicators
Issued 28 October 2003 Resolved
Make permanent repairs to bilge high level alarm. LEGACY COMPONENT DESC: Bilge Alarm
Due 11 November 2003
Resolved 14 November 2003
Engineering › Fuel Oil Service System
Issued 28 October 2003 Resolved
Properly attach grounding strap on fuel system. LEGACY COMPONENT DESC: Hose
Due 11 November 2003
Resolved 14 November 2003
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 28 October 2003 Resolved
Prove proper operation of fixed fire extinguishing system. LEGACY COMPONENT DESC: Operating Controls
Due 5 November 2003
Resolved 18 May 2004
Documentation
Issued 15 October 2001 Resolved
Provide proof of supervisory training (60 minutes).
Condition: Unknown
Due 29 October 2001
Resolved 6 November 2001
Lifesaving
Issued 15 October 2001 Resolved
Post lifejacket donning placard.
Condition: Unknown
Due 29 October 2001
Resolved 6 November 2001
Lifesaving
Issued 15 October 2001 Resolved
Provide first aid kit that complies with 46 CFR 160.041.
Condition: Unknown
Due 29 October 2001
Resolved 6 November 2001
Lifesaving
Issued 15 October 2001 Resolved
Provide watertight container for distress flares.
Condition: Unknown
Due 29 October 2001
Resolved 6 November 2001
Construction/Loadline
Issued 15 June 2000 Resolved
PROPERLY INSTALL A BILGE HIGH LEVEL ALARM FOR ENGINE COMPARTMENT.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Lifesaving
Issued 15 June 2000 Resolved
PROVIDE 3 ORANGE SMOKE FLARES OR 3 ADDITIONAL RED FLARES ON BOARD VESSEL.
Condition: Unknown
Due 14 July 2000
Resolved 14 July 2000
Documentation
Issued 15 June 2000 Resolved
PROVIDE STABILITY LETTER ON BOARD VESSEL AND SEND COPY OF STABILITY LETTER TO [name withheld].
Condition: Unknown
Due 14 July 2000
Resolved 14 July 2000
Fire Fighting
Issued 15 June 2000 Resolved
PROVIDE PROOF OF ANNUAL FIXED FIRE EXTINGUISHER SERVICING.
Condition: Unknown
Due 14 July 2000
Resolved 14 July 2000
Unknown
Issued 1 June 2000 Resolved
Provide crew training.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Unknown
Issued 1 June 2000 Resolved
Provide drug testing program.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Unknown
Issued 1 June 2000 Resolved
Conduct drills to the satisfaction of attending Marine Inspector.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Unknown
Issued 1 June 2000 Resolved
Provide licensed operators.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.