MAURY USCG vessel records
← All vessels

PORTAITISSA

PORTAITISSA is a 2006 freight ship. The Coast Guard has recorded 3 inspections since 2018, most recently in April 2025, along with 1 deficiency.

Records from 2018 to 2025. Most recent: inspection, 8 April 2025.

Built
2006
Last inspected
8 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 April 2025
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2018–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9323883
867135
Flag
PANAMA
Maury page id
psix-867135

Documentation record

Tonnage as PSIX records it87144 - Dead Weight, Metric Ton
100171 - Displacement, Metric Ton
47051 - Convention (Subpart B), Gross Ton
27005 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

8 April 2025 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8105052
4 April 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8105168
31 January 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6333534

Deficiency record · 1

Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 31 January 2018 Resolved
0899- Other- Transfer pipe must not leak under static liquid pressure 1.5 times max allowable pressure hydrostatic test. Vessel did not provide document attesting to sufficient hydrostatic testing. Vessel must provide documentation prior to bunkering in the U.S. 33CFR156.170 c.
Condition: Placed in Improper Service
Action required: 703 - Prior to bunkering operations
Due 1 February 2018
Resolved 2 February 2018
Resolution: Received proper documentation clearing this deficiency.

Ownership record