This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it104866 - Dead Weight, Metric Ton 122182 - Displacement, Metric Ton 58088 - Convention (Subpart B), Gross Ton 30727 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 9
24 September 2019Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6819658
16 April 2019Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6663789
11 October 2018Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6559091
6 April 2018Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6386977
26 September 2017ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6271514
16 September 2016COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6000873
19 February 2016Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5818581
18 February 2016ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5817424
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019Resolved
0902: No electrical equipment shall be installed in any space where flammable mixtures are liable to collect, unless the administration is satisfied that such equipment is of a type which will not ignite the mixture concerned. PSCO observed 09 explosion-proof lighting fixtures (08 in cargo pumproom, 01 on aft main deck) integrity compromised (cracked casing, cracked metal frame, lack of electrical bonding). 74 SOLAS (04) II-1/45.10.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2019
Resolved 24 September 2019
Resolution: RECIEVED CLASS REPORT ATTESTING TO REPAIR OF LIGHTING FIXTURES.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 September 2019Resolved
07133: Each system required by this subpart to be intrinsically safe must use approved components meeting UL 913 or IEC 60079-11. PSCO observed 10 UHF handheld radios that were not matched with approved batteries and therefore are not intrinsically safe. 46 CFR 111.105-11 17ac
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2019
Resolved 24 September 2019
Resolution: RECIEVED REPORT FROM CLASS STATING ISSUE WAS RECTIFIED BY HAVING OTHER RADIOS ON BOARD THAT HAD BEEN ORDERED.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 24 September 2019Resolved
06199: The machinery, boilers and other pressure vessels, associated piping systems and fittings shall of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons onboard. PSCO observed temporary splash guard placed on No. 3 cargo pump, residue of cargo from apparent leak in cargo pump. 74 SOLAS (04) II-1/26.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2019
Resolved 24 September 2019
Resolution: RECIEVED CLASS REPORT AND ISSUE WAS RESOLVED.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 September 2019Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 September 2019
Resolved 24 September 2019
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.