SOMBEKE is a 2006 tank ship. The Coast Guard has recorded 21 inspections since 2016, most recently in March 2026, along with 8 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 12 March 2026.

Built
2006
Last inspected
12 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 March 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9292113
V7A7432
867242
Flag
MARSHALL ISLANDS
Maury page id
psix-867242

Documentation record

Tonnage as PSIX records it41151 - Displacement, Metric Ton
29213 - Dead Weight, Metric Ton
25994 - Convention (Subpart B), Gross Ton
7799 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

12 March 2026 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8325015
13 January 2026 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8295661
2 March 2025 COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8086888
22 November 2023 PSC B · COC-GAS Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7826046
30 May 2023 PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7696986
21 November 2022 COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7597687
5 August 2021 COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7275167
5 March 2021 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7147232
30 July 2020 COC-GAS Renew
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7013897
16 October 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6835509
12 October 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6833369
3 July 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6735088
13 June 2019 COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6706419
14 May 2019 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6727880
16 January 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6610892
3 May 2018 Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6404748
6 April 2018 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6386365
12 March 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6104052
1 February 2017 ISPS II Exam · COC-GAS Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6078821
23 February 2016 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5820245
3 February 2016 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5806141

Deficiency record · 8

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 November 2022 Resolved
Pressure Relief valves should be set and sealed by a competent authority acceptable to the Administration and a record of the is action, including the valves of set pressure, should be retained aboard the ship. PSCO observed missing seal on the COT#1 PRV. Additionally, the ship does not have any official documentation from the Administration or class accepting the sealing of both port and starboard deck tank pressure relief valve seals.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2022
Resolved 19 December 2022
Resolution: Conducted deficiency check vessel provided set and seal certificate provide by class attesting to the set pressure of the MARV's IAW the vessel SOE.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 30 July 2020 Resolved
10114- To assist in casualty investigations ships, when engaged on international voyages subject to the provisions of regulation 1.4 shall be fitted with a voyage data recorder. PSCO observed three (3) alarms on VDR display on Nav Bridge. 74 SOLAS (2014) V/20.1 17 A/C
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2020
Resolved 1 August 2020
Resolution: Service tech from Radio Holland boarded the vessel. Caused was due to grounding fault between float-free capsule and VDR core module was not allowing the communication to the float-free module. Connection was restored and found VDR fully operational.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 13 June 2019 Resolved
Gas detection equipment acceptable to the administration and suitable for the gases to be carried should be provided in accordance with column f in the table of chapter 19. During COC examination, the vessel was using 35% LEL propane to calibrate their fixed gas detection, while the vessel was loaded with anhydrous ammonia. The current arrangement was designed to reflect the flammability dangers of anhydrous ammonia but failed to capture the toxic dangers of anhydrous ammonia. The safety sheet issued to the vessel stated that the short term exposure limit was 25 ppm. Current flammable detection would alarm when there was approximately 25,000 ppm of anhydrous ammonia in the space. 74 SOLAS (14) VII/13.1 IGC (93) 12.6.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 16 October 2019
Resolution: New monitoring device installed in MOSS gas dectection system on 08/24/2019 for ppm measurement and alarm. System was satisfactorily tested.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 3 May 2018 Resolved
1410-Propulsion Main Engine-The condition of the ship and its equipment shall be maintained to conform with the present regulation to ensure that the ship will remain fit to proceed to sea. Vessel experienced loss of cylinder #4 on main engine during outbound transit. 74 SOLAS (14 Cons.) CH 1, Reg. 11(a).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2018
Resolution: Replaced puncture valve on #4 pressure pump.
Deck/Cargo › Cargo Stowage › General
Issued 6 April 2018 Resolved
1870-Tankers-Special requirements-the system should be capable of covering all areas mentioned in 11.3.1 with a uniformly distributed water-spray of at least 101 m2 per minute...Vessels deck water spray has no water flow on 3 nozzles stbd deck tank and very little flow on both port and stbd manifold. 74 SOLAS(14)VII/13.1, IGC (93)11.3.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 April 2018
Resolved 6 April 2018
Resolution: Vessel crew flushed out deck water spray system. Nozzles are now in proper working order.
Deck/Cargo › Holds/Tanks › Watertight Door
Issued 6 April 2018 Resolved
1899-(other)Tankers-An airlock should only be permitted between a gas-dangerous zone on the open weather deck and a gas safe space and should consist of two steel doors substantially gas tight. Vessels outer air lock door was not gas tight, visible day light around the door. 74 SOLAS (14)VII/13.1,IGC (93)3.6.1.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 13 April 2018
Resolved 11 April 2018
Resolution: The alignment of closing device was done by crew in presence of chief officer prior to depature and chalk test carried our satisfactorially. (Pictures in documents)
Deck/Cargo › Holds/Tanks › Venitlation Fans
Issued 6 April 2018 Resolved
1870-Tankers-special requirements-electric motor rooms cargo compressor rooms, and pump rooms; Provision should be made to ventilate such spaces prior to entering; a warning notice requiring the use of such ventilation should be placed outside the compartment. Vessel did not have a sign outside of cargo compressor room. 74 SOLAS (14) VII/13.1, IGC (93)12.1.1.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 May 2018
Resolved 11 April 2018
Resolution: A warning notice was posted outside the door prior departure. (Pictures attached)
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 3 February 2016 Resolved
Each device must be free of design defects such as rough or sharp edges that may cause bodily injuries or that would allow toxic substances to escape to the interior of the vessel. The side wall of marine sanitation device has unauthorized repair. (33CFR 159.95(a)(1)) (40a,c)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 February 2016
Resolved 23 February 2016
Resolution: Vessels Marine Sanitation Device repaired to the satisfaction of attending class surveyor.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.