MAURY USCG vessel records Sign in
← All vessels

ALPHA AND OMEGA

ALPHA AND OMEGA is a 1969 unclassified. The Coast Guard has recorded 2 inspections in 2007, along with 11 deficiencies and 1 operational control.

Records in 2007. Most recent: operational control imposed, 26 April 2007.

Built
1969
Last inspected
26 April 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6916902 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ZKU2116
868002
Flag
COOK ISLANDS
—
Maury page id
psix-868002

Inspections, by type

Years with a record 1 calendar year (2007)
The 2 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it485 - Convention (Subpart B), Gross Ton
247 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 2

26 April 2007 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2916109
4 April 2007 Deficiency Check · MTSA/ISPS Verification · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2901779

Deficiency record · 11

Operations/Management › Drills/Instruction › Fire
Issued 26 April 2007 Resolved
Vessel failed fire and abandon ship drills.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2007
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 26 April 2007 Resolved
Firemans outfit is not steam- scald proof in accordance with FSS code.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2007
Resolved 26 April 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2007 Resolved
Exposed wiring in starboard cargo hold. No light guard in port cargo hold for one light. No light guard in galley for one light.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2007
Resolution: Sited Corrected def
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 4 April 2007 Resolved
Portside galley door does not seal entirely when closed. Without proper seal the A-60 fire boundary is compromised.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2007
Resolution: Vessel adjusted door sealing properly
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 4 April 2007 Resolved
No operable bilge alarms in starboard or port cargo holds. Wiring to alarms were detached.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 May 2007
Resolved 26 April 2007
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 4 April 2007 Resolved
No fire control plan onboard.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2007
Resolution: Sited Approved FCP
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 4 April 2007 Resolved
No retro-reflective tape on any of the life ring buoys.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2007
Resolution: 31 Sq Inch of retro sited on buoys
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 4 April 2007 Resolved
No visible deckline above the loadline is properly marked with contrasting color.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2007
Resolution: Sited white deck line on blue hull
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 4 April 2007 Resolved
various ladder rung found wasted replace as necessary
Due 15 May 2007
Resolved 26 April 2007
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 4 April 2007 Resolved
Wooden plug found as scuppers drains Vessel to replace all pugs with mechanical type
Due 15 May 2007
Resolved 26 April 2007
Operations/Management › FireFighting › Patrol System (Special Category Spaces)
Issued 4 April 2007 Resolved
NO FIRE DRILL CONDUCTED VESSEL CREW WAS ENGAGED WITH CBP/ICE AT TIME OF INSPECTION CONDUCT FIRE AND BOAT DRILL
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2007

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.