MAURY USCG vessel records
← All vessels

CHEMTRANS SATURN

CHEMTRANS SATURN is a 2006 tank ship. The Coast Guard has recorded 24 inspections since 2016, most recently in October 2022, along with 9 deficiencies and 3 operational controls.

Records from 2016 to 2022. Most recent: operational control imposed, 19 October 2022.

Built
2006
Last inspected
19 October 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 October 2022
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9309007
868367
Flag
LIBERIA
Maury page id
psix-868367

Documentation record

Tonnage as PSIX records it86147 - Displacement, Metric Ton
72246 - Dead Weight, Metric Ton
40698 - Convention (Subpart B), Gross Ton
20376 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

19 October 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7580633
13 September 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7558418
18 August 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7537736
21 July 2022 PSC B · COC-TVE Renew · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7510523
4 November 2019 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6849285
14 August 2019 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6782281
5 April 2019 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6656967
2 April 2019 COE-Administrative
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6654533
4 June 2018 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6433918
31 May 2018 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6420865
21 December 2017 Administrative Inspection · COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6323603
9 November 2017 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6304503
9 November 2017 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6305861
11 October 2017 ISPS III Exam · In-Service Inspection · Deficiency Check · COE-Dockside
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6285022
10 October 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6285090
6 October 2017 COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6280389
10 July 2017 Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6204104
10 July 2017 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6207923
3 June 2017 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6150760
4 January 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6069408
15 August 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5973157
17 July 2016 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5943076
3 June 2016 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5896243
28 May 2016 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5882694

Deficiency record · 9

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 21 July 2022 Resolved
Tankers shall be equipped wit hat least one portable instrument for measuring oxygen and one for measuring flammable vapour concentrations, together with a sufficient set of spares. Vessel only had one functioning portable instrument.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 July 2022
Resolved 26 July 2022
Resolution: Agent delivered portable gas detector to tanker.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 July 2022 Resolved
Fire resistance of doors shall be equivalent to that of the division in which they are fitted. Engine room and galley fire door gaskets were worn and frayed.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 August 2022
Resolved 19 August 2022
Resolution: Vessel sent class report attesting to rectification.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 21 July 2022 Resolved
If a vessel is fitted with a VCS, their transfer procedures must contain a description of the VCS on the vessel. VECS certificate is missing for collection of cargo vapors in accordance with 33CFR155.750(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2022
Resolved 13 September 2022
Resolution: Received class document that VCS is in compliance with 33CFR155.750(d).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 August 2019 Resolved
The inert gas system referred to in paragraph 5.5.3.1 shall be designed constructed and tested in accordance with Fire SAfety Systems Code. PSCO observed 6 inche heavy corrosion (full penetration of metal) on flue gas inlet to scrubber. 74 SOLAS (CON 14) Ch. II-2 Regualtion 4.5.5.3.2
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Def corrected. See class report for further details.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 31 May 2018 Resolved
Except where otherwise stated, the normal equipment of every lifeboat shall consist of a food ration totaling not less than 10,000kj for each person the lifeboat is permitted to accommodate. Both lifeboats are rated to accommodate 30 POB and only 29 rations for each lifeboat are not expired. SOLAS (2014)CH III/REG 34 L.S.A IV/4.4.8.12
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2018
Resolved 4 June 2018
Resolution: Verified food rations for both lifeboats, attached invoice for purchase. Each lifeboat contains 30 Rations for each 30 person lifeboat.
Navigation › Piloting/Steering › Gyro Compass
Issued 11 October 2017 Resolved
1540-Gyro Compass Inoperable 74SOLAS(09)V/19.2.5.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2017
Resolution: technician attended and found fluid had leaked from container. Replaced container and sphere and filled with new fluid. calibrated ROT meter and verified heading to chart.
Electrical › Electric Generation Source (emergency) › Generator
Issued 28 May 2016 Resolved
0950-Electrical equipment in general-Where the emergency source of electrical power is a generator, it shall start automatically upon failure of the main source of electrical power supply. PSCO observed that emergency generator was unable to start using the supplied batteries. SOLAS 74a II-1/43.3.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2016
Resolved 28 May 2016
Resolution: Received Class report attesting to the repair and operation of emergency generator.
Lifesaving › Inflatable Liferafts › Painter
Issued 28 May 2016 Resolved
0620-inflatable liferafts-Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed all four inflatable liferaft painter lines coupled to the pelican hooks instead of weak link as per instructions. SOLAS 74a III/20
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2016
Resolved 28 May 2016
Resolution: Received Class report attesting to the proper stowage of liferafts.
Lifesaving › Lifeboat › Hull
Issued 28 May 2016 Resolved
0610-lifeboats-Cargo ships shall carry totally enclosed lifeboats complying with the requirements of section 4.6 of the code. PSCO observed breach in hull above the water line on the starboard lifeboat. SOLAS 74a III/31
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 10 June 2016
Resolution: Recieved documentation from the [name withheld] attesting to permenent repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.