MAURY USCG vessel records
← All vessels

GAJA

GAJA is a 2006 freight ship. The Coast Guard has recorded 10 inspections since 2016, most recently in July 2022, along with 7 deficiencies and 5 operational controls.

Records from 2016 to 2022. Most recent: operational control imposed, 21 July 2022.

Built
2006
Last inspected
21 July 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 July 2022
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9273791
868518
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-868518

Documentation record

Tonnage as PSIX records it5766 - Convention (Subpart B), Net Ton
12767 - Dead Weight, Metric Ton
18550 - Displacement, Metric Ton
10899 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

10 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; 5 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

21 July 2022 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7510019
5 July 2022 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7497294
31 May 2022 MARPOL Annex I Examination · PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7456551
19 June 2021 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7229273
7 June 2019 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6706798
23 May 2019 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6691515
6 May 2019 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6684683
11 October 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6559036
17 August 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5986732
4 January 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5786903

Deficiency record · 7

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 21 July 2022 Resolved
New personnel and personnel transferred to new assignments related to safety and protection of the environment are given proper familiarization with their duties. PSCOs noted that members of the crew were unsure of various bridge and navigational safety procedures and operations on board the vessel. An external audit and demonstration of crew familiarity is required to be conducted and submitted prior to departure from port.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2022
Resolution: Vessel provided proof that an ISM audit was conducted as well as the crew being retrained. For more information please see attached documents.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 21 July 2022 Resolved
New personnel and personnel transferred to new assignments related to safety and protection of the environment are given proper familiarization with their duties. PSCO's witnessed engineering crew not familiar with the piping arrangements of the oily water separator. An external audit and demonstration of crew familiarity is required to be conducted and submitted prior to departure from port.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2022
Resolution: Vessel provided proof that an ISM audit was conducted as well as the crew being retrained. For more information please see attached documents.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 July 2022 Resolved
Every inflatable life raft shall be serviced at intervals not exceeding 12 months, the Administration may extend to 17 months. Life rafts on board vessel exceed 12 month service interval. Vessel has dispensation from Liberia. Antigua and Barbuda are the vessel's current flag state.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2022
Resolution: Vessel provided circular SLS.14Circ.499 Extended life raft service. Life Rafts are going to be replaced upon arrival to Panama.
14 - Pollution Prevention › 141 - MARPOL Annex I › Suspected of discharge violation
Issued 31 May 2022 Resolved
Any discharge into the sea of oil or oily mixtures shall be prohibited except when the oil mixture is processed through oil filtering equipment. -Whistleblower reports corroborated by shipboard Officers reveal vessel utilizing means to discharge oily water into the sea by bypassing the installed oil filtering equipment. Picture and corroborated witness statements from shipboard Officers to USCG PSCO's evidence use of portable hoses and portable pneumatic pump connecting the bilge wells to the sewage holding tank via sewage holding tank sounding tube where the oily water mixture was discharged overboard. MARPOL I/15.2.2
Action required: 30 - Ship detained
Resolved 6 June 2022
Resolution: ISM audit addressed deficiency concerns.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 31 May 2022 Resolved
The oil record book shall be completed on each occasion there is a discharge overboard of bilge water which has accumulated in machinery spaces. -Whistleblower reports corroborated by shipboard Officers reveal vessel not recording overboard discharges of bilge water which has accumulated in the engine room bilge wells. Bilge water was transferred via portable hoses and portable pneumatic pumps from the bilge wells to the sewage tank where it was discharged. MARPOL I/17.2
Action required: 30 - Ship detained
Resolved 6 June 2022
Resolution: Received ISM audit which addressed deficiency concerns.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 31 May 2022 Resolved
The company should ensure that the safety and environmental policy is implemented and maintained at all levels of the organization, both ship-based and shore-based. -Whistleblower reports corroborated by shipboard Officers reveal vessel utilizing means to discharge oily water into the sea by bypassing the installed oil filtering equipment. Picture and corroborated witness statements from shipboard Officers to USCG PSCO's evidence use of portable hoses and portable pneumatic pump connecting the bilge wells to the sewage holding tank via sewage holding tank sounding tube where the oily water mixture was discharged overboard. This serves as evidence that the company environmental protection policy is not implemented at all levels of the organization. In order to clear this deficiency, an audit must be completed and submitted to USCG. ISM Code 2.2
Action required: 30 - Ship detained
Resolved 6 June 2022
Resolution: ISM audit addressed deficiency.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 4 January 2016 Resolved
0799 - Other (Fire Fighting Equipment) - Operational Readiness - Firefighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO's observed 03 flame sensors for the water mist system in the engine room damaged. PSCO's were unable to verify proper operation of entire system - 74 SOLAS 04 con. II-2 / 14.2.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 7 January 2016
Resolved 8 January 2016
Resolution: Received documentation from [name withheld] stating that outstanding deficiency has been cleared.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.