Records from 2016 to 2025. Most recent: inspection, 24 November 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Professional
Detail on this page
14 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 14
24 November 2025
Hull Examination · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8250099
12 June 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8139961
6 June 2024
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7917665
26 June 2023
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7709319
29 June 2022
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7477174
28 June 2021
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7234826
14 October 2020
Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7074562
16 June 2020
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6967219
11 June 2019
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6706734
22 May 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6420446
29 June 2017
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6182947
9 March 2017
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6030840
13 September 2016
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5999534
27 June 2016
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5913049
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be serviceable must be replaced.
04 life jackets were found with deteriorated flotation and worn retro reflective tape. Passenger count for this vessel has been reduced to 3 passengers, until replacements are onboard.
46 CFR 176.808
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2024
Resolved 10 June 2024
Resolution: Vessel representative emailed photo of (04) new Type 1 life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 June 2024
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacketwater temperature, and lubricating oil pressure must be provided for propulsion engines.
The vessel doesn't have a means for monitoring these engine parameters. Install gauge and alarms.
46 CFR 182.410
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2024
Resolved 16 July 2024
Resolution: Installed tach and alarms.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 26 June 2023
Resolved
Primary consideration shall be given to the provision of a seaworthy hull, protection against fire, means of escape in case of sudden unexpected casualty, guards and rails in hazardous places, ventilation of closed spaces, and necessary facilities for passengers and crew.
Vessel is equipped with a ladder for passengers to enter and exit the water. MI discovered multiple cracked welds connecting the rungs to the side rails of the ladder.
46 CFR 177.01-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2023
Resolved 28 June 2023
Resolution: Vessel representative sent over satisfactory photos of weld repairs on ladder.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 29 June 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel giving consideration to necessary facilities for passengers and crew.
Vessel is equipped with a ladder for passengers to enter and exit the water. MI discovered multiple cracked welds connecting the rungs to the side rails of the ladder.
46CFR177.100
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2022
Resolved 2 August 2022
Resolution: Received email with photos of repaired ladder.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 June 2022
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter.
MI discovered the battery in the floating waterlight was expired. Vessel limited to daylight operation only.
46CFR180.70(d)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 August 2022
Resolution: Received email from RAOVAC stating the date on the battery is manufacture date, and it is good for 3 years.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 June 2022
Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA 10.
Vessel did not have any record of monthly maintenance checks.
46CFR176.810(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 June 2022
Resolution: Vessel will keep a log going forward.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 June 2021
Resolved
All other vessels must undergo an inspection for certification as specified in 176.404 and annual inspection as specified in paragraph (b)(1) of this section.
Vessel did not conduct COI renewal prior to expiration.
46 CFR 176.500 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2021
Resolution: Completed renewal inspection.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 29 June 2017
Resolved
Provide retro-reflective tape for life ring buoy.
Condition: Improper/Lack of Maintenance
Due 7 July 2017
Resolved 14 July 2017
Resolution: Replaced retro-reflective tape on buoy.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 June 2017
Resolved
Position port and starboard navigation lights meeting nav rules for a 225 degree arc of visibility. Daylight operation only w/no visibility restriction.
Condition: Improper Installation
Due 7 July 2017
Resolved 14 July 2017
Resolution: Remounted nav lights to meet requirements of nav rules
Documentation › Certificates/Documents › Stability Letter
Issued 9 March 2017
Resolved
Submit additional information and/or calculations required for passengers to access forward ladder to the MSC. 46CFR 178.310
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2018
Resolution: Deficiency resolved
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 March 2017
Resolved
Prove rail heights are at least 39.5" when operating on a sightseeing or excursion trip. 46CFR 177.900
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2018
Resolution: Deficiency resolved