MAURY USCG vessel records Sign in
← All vessels

GAZ VENEZIA

GAZ VENEZIA is a tank ship. The Coast Guard has recorded 5 inspections since 2007, most recently in April 2021, along with 5 deficiencies and 2 operational controls.

Records from 2007 to 2021. Most recent: inspection, 2 April 2021.

Built
Not recorded
Last inspected
2 April 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9013701 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
869127
Flag
PANAMA
—
Maury page id
psix-869127

Inspections, by type

…with no type recorded2
Years with a record 3 calendar years (2007–2021)
The 5 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6118 - Simplified, Net Ton
11624 - Displacement, Metric Ton
7515 - Dead Weight, Metric Ton
6118 - Convention (Subpart B), Gross Ton
6118 - Simplified, Gross Ton
2076 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 5

2 April 2021 COC-GAS Renew · Deficiency Check · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7164059
9 September 2010 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3845469
9 September 2010 Type not recorded
No type recorded · Liquefied Gas Carrier National Center of Expertise · Activity 3848722
21 March 2007 COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2892272
20 March 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2891705

Deficiency record · 5

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 2 April 2021 Resolved
Gas detection equipment acceptable to the administration and suitable for the gases to be carried should be provided. Fixed gas detection equipment failed calibration multiple times, sensor was replaced and calibration completed. Flow failure alarm was never demonstrated to be operational as outlined in fixed gas detection manual. Vessel to provide classification society attestation that fixed gas detection system installed is fully operational as per onboard maintenance manual. Clear prior to loading cargo.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 May 2021
Resolution: The fixed gas detection was serviced, calibrated by service engineer from QCONCORP, the flower meter was adjusted and calibrated and confirmed in order. The function test of system including demonstrating the flow failure alarm
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 April 2021 Resolved
An airlock should only be permitted between a gas dangerous zone on the open weather deck and a gas safe space and should consist of two steel doors substantially gastight spaced atleast 1.5 m but not more than 2.5m apart. Exterior door to motor room is not gastight. Prior to loading cargo.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 May 2021
Resolution: Exterior door of motor room was repaired by the crew.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 2 April 2021 Resolved
A water spray system for cooling, fire prevention, and crew protection should be installed to cover; exposed cargo domes and any exposed parts of cargo tanks. The port manifold and the #1 port and starboard tank domes were not properly protected by the water spray system.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 April 2021
Resolved 2 April 2021
Resolution: Anchor wash was running and crew cleaned out nozzles allowing for adequate pressure throughout the system.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 April 2021 Resolved
Intrinsically safe electrical equipment and wiring may be fitted in all gas-dangerous spaces and zones. There was exposed dead end wiring in the motor room and a non-intrinsically safe light fixture above the #3 tank top. Rectify prior to loading cargo.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 25 May 2021
Resolution: Removed dead wiring and covered light fixtures
Construction/Loadline › Structures › Door
Issued 9 September 2010 Resolved
Vessel's entrance into the motor room from the air lock does not self close making the door not gastight. Both doors of an air lock should be self closing and gastight. Repair door to the satisfaction of attending classification society surveyor.
Action required: 705 - Other - as specified
Due 9 October 2010
Resolved 6 October 2010
Resolution: Received satisfactory class report attesting to the repair and subsequent gas tightness of the airlock doors.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.