MAURY USCG vessel records Sign in
← All vessels

JADE BLOSSOM

JADE BLOSSOM is a 2006 tank ship. The Coast Guard has recorded 17 inspections since 2007, most recently in May 2018, along with 5 deficiencies and 4 operational controls.

Records from 2007 to 2018. Most recent: inspection, 27 May 2018.

Built
2006
Last inspected
27 May 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9354179 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
870038
Flag
HONG KONG
—
Maury page id
psix-870038

Inspections, by type

…with no type recorded6
Years with a record 9 calendar years (2007–2018)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it13602 - Convention (Subpart B), Net Ton
51253 - Dead Weight, Ton
61351 - Displacement, Ton
30068 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

27 May 2018 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6415731
1 April 2016 COE-Dockside
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5845014
29 March 2016 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5843322
8 November 2015 COE-Administrative
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5760115
4 October 2015 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew · COC-CHEM Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5735052
24 October 2014 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5011533
1 January 2012 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4216703
18 December 2011 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4205495
15 April 2009 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3453446
6 February 2008 ISPS II Exam · Ballast Water Examination · COC-CHEM Annual
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3142334
28 December 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3125847
12 June 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2959592
12 June 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2959783
11 June 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2955653
2 May 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2917870
2 May 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2921079
16 January 2007 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2858241

Deficiency record · 5

Operations/Management › Ballast Water Managment › Sediments
Issued 17 October 2015 Resolved
ANY VESSEL EQUIPPED WITH BALLAST TANKS SHALL MAINTAIN A BWM PLAN THAT INCLUDES THE ACTIONS FOR IMPLEMENTING THE BWM PRACTICES IN THIS PART AS WELL AS DETAILED FOULING AND SEDIMENT REMOVAL PROCEDURES. VESSEL HAD A BWM PLAN DATED FROM 2006, THIS PLAN DID NOT MEET THE REQUIREMENTS OF THE CFR AND DID NOT CONTAIN PROCEDURES FOR FOULING MAITENANCE AND SEDIMENT REMOVAL.33CFR151.2050(g)
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 October 2015
Resolved 2 November 2015
Resolution: Vessel Management Submitted Plan that met requirements.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 17 October 2015 Resolved
THE SHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE ISM CODE. THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THE VESSEL HAS PROCEDURES FOR KEY SHIPBOARD OPERATIONS AND ALL RELEVANT DOCUMENTS WHICH ARE RELEVANT TO SMS. THE SMS REQUIRES THE OWS TO BE TESTED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. OWS WAS NOT TESTED IAW MAN. RECS AND MANUFACTURER'S INSTRUCTIONS WERE INCOMPLETE.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 October 2015
Resolved 17 October 2015
Resolution: EDUCATED CHIEF ENGINEER. CORRECTED ON THE SPOT.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 18 December 2011 Resolved
0750-Fire Prevention- Instrumentation shall be fitted for continuously indicating and permanently recording, when inert gas is being supplied. The oxygen analyzer for the inert gas generator has been removed and sent to shore for service. PSCO cannot confirm proper operation of the system. Vessel is prohibited from conducting caro operations that require inert gas SOLAS 74(a) AnnexI/11FSScode CH15
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2011
Resolved 1 January 2012
Resolution: PSCO verified by span gas and zero gas proper calibration of oxygen analyzer.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 18 December 2011 Resolved
1745- 15ppm alarm arrangements- The engineering department is unaware that the OCM records operational data for OWS operations and cannot demonstrate the ability to retrieve the data from the system.- MARPOL 73/78 Annex I/11, MEPC 107(49)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 December 2011
Resolved 1 January 2012
Resolution: C/E demonstrated proper operation of OCM data history.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 12 June 2007 Resolved
IGS generator currently inoperable. Vsl is not capable of inerting the cargo tanks in accordance w/ the manufacturer's instructions. Prove the ability to maintain tanks at an inert condition and provide class report attesting to the satisfaction of repairs to the IGS generator/system prior to movement to the satisfaction of Class and the Administration
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2007
Resolution: Received class report staing that the IG generator is now operational. The fault was found to be a defective relay (IY82) and loose wire located in the Fire Control Staion IG panel.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.