Records from 2006 to 2026. Most recent: inspection, 23 April 2026.
Inspection history · 13
23 April 2026
Uninspected Other
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8354892
20 August 2025
Deficiency Check · Uninspected Other
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8214260
7 August 2025
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8204820
10 October 2024
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8019749
1 October 2024
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8012540
6 September 2023
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7786894
9 August 2023
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7765045
5 April 2023
In-Service Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7667125
8 May 2022
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7452951
6 April 2022
Initial Certification · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7431683
25 March 2014
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4979757
20 March 2014
Industry Initiated Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4819549
31 July 2006
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2853500
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 April 2023
No resolution recorded
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. There are two, approximately 4ft x 3ft holes cut into the aft engine room bulkhead to accommodate the location of the vessel's Z drives. Current configuration does not allow ventilation to be secured to the engine room in case of fire. Additionally, holes pose a risk of down flooding in the engine room. Repairs must be made prior to movement. Submit repair proposal to [name withheld] changes to the vessel's original structure or arrangement will require plan approval in accordance with 46 CFR Part 144.
Action required: 60 - Rectify deficiencies prior to movement
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2023
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times. Engine room has multiple deficiencies including fuel leaks,disconnected wiring, and debris scattered throughout the engine room including: tools, parts, trash and drums and buckets of flammable liquids. It is evident that owner/operator is not proactively managing the vessel. Vessel is required to undergo full COI inspection prior to operation.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 August 2025
Resolution: Engine room was found in good condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 April 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Starboard generator is inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 August 2025
Resolution: Generator operated satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 April 2022
Resolved
Each towing vessel must carry at least one appropriately sized approved lifejacket for each person onboard. There were no approved lifejackets onboard. Vessel shall have one approved lifejacket onboard for each person onboard.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 April 2022
Resolution: ACOE provided all required PFD's onboard in an appropriate container labeled "Life Jackets".
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 April 2022
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. All the life rings onboard were weathered to the point that the plug was rotted off and the grab lines were falling apart. The vessel shall be fitted with new or well maintained life rings.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 April 2022
Resolution: ACOE personnel replaced all life rings onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 April 2022
Resolved
Fire hoses must be fitted with a nozzle made of corrosion resistant material capable of providing a solid stream and a spray pattern. None of the fire hoses onboard were fitted with a nozzle. Each fire hose shall be fitted with an appropriate nozzle.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 April 2022
Resolution: ACOE personnel provided all required fire hose nozzles onboard.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 6 April 2022
Resolved
Each towing vessel must be fitted with a general alarm. There is no general alarm installed onboard. Vessel shall install a general alarm or identify a USCG approved alternate means to notify all persons onbard of an emergency.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 April 2022
Resolution: ACOE personnel installed an appropriate general alarm onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 April 2022
Resolved
Flammable or combustible products must be stored in a designated storage room or cabinet when not in use. Observed an unattended gasoline container sitting on the outboard weather deck. Vessel shall store flammable/combustible products in an appropriate location.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 April 2022
Resolution: ACOE personnel have stored all flammable and combustible products in an appropriate flammable/combustible storage locker.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 April 2022
Resolved
Compressed gas cylinders must always be secured and, when not in use, stowed in a rack in an upright position with the valve protection cap in place. Observed an unsecured oxygen/acetylene cylinder combo on the deck. Vessel shall store and secure these compressed gas cylinders as required by regulation.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 April 2022
Resolution: ACOE personnel removed the oxy/acetylene from the vessel as there was not an appropriate storage rack for these compressed gas cylinders.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 April 2022
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. All the first aid kits onboard were observed to be expired. Vessel shall replace the first aid kits onboard in compliance with the regulations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 April 2022
Resolution: ACOE personnel replaced all first aid kits onboard with new, not expired kits.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 April 2022
Resolved
Towing vessels must carry a combination of day/night visual distress signals. Vessel did not have distress signals onboard. Vessel shall place the appropriate types and quantities of visual distress signals onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 8 May 2022
Resolution: Recd confirmation via email and photos that the VDS order arrived and was placed onboard the vessel. Delay past 30 days due to supply chain issues, no additional action necessary.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 6 April 2022
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The vessel did not have any of the alarms or gauges required by 46CFR143.230. The vessel shall install the required alarms and gauges onboard the vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 20 April 2022
Resolution: Vessel has a summary alarm in accordance with 46CFR143.230(b)(1) and staffs an unlicensed engineer to monitor engine room during operations therefore the full suite of alarms required by 142.230(a) at the operating station is not required.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 April 2022
Resolved
Records of drills and instruction must be maintained in the TVR or official logbook. There are no records of the required drills and instruction onboard. The master of the vessel shall record and maintain the records of all required drills in accordance with the regulations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 20 April 2022
Resolution: Vessel conducts drills/training with the crew of the vsl HURLEY & all previous drills/training have been logged in the HURLEY's log. As per the ACOE POC, all current & future drills/training will be logged in the WARD's log.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 April 2022
Resolved
A towing vessel must maintain a Towing Vessel Record (TVR). There is no TVR onboard. Vessel shall create and maintain a TVR onboard and make it available for inspection by the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 20 April 2022
Resolution: Vessel has started a Towing Vessel Record (TVR) and will begin documenting all required TVR info for future inspections.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 April 2022
Resolved
The master of each towing vessel must ensure the personnel records required by 46 CFR 140.400 is recorded, logged, and maintained onboard. There are no personnel records onboard. Vessel shall meet the personnel records requirements of 46 CFR 140.400
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 20 April 2022
Resolution: Required personnel records were previously kept onboard the dredge HURLEY. As per ACOE POC, this information will now also be kept/logged in the WARD's logbook/TVR.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 April 2022
Resolved
Fire detection system design and installation must be certified by a registered professional engineer [name withheld] letter was not available for review. The PE letter must be made available for review by a USCG inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 6 April 2022
Resolution: After the inspection on 06APR2022, the ACOE POC emailed a copy of the PE letter to SEC LMR and it met the requirements.