MAG 572 is a 2007 tank barge. The Coast Guard has recorded 22 inspections since 2007, most recently in July 2026, along with 11 deficiencies and 1 casualty investigation in 2013.
Records from 2007 to 2026. Most recent: inspection, 29 July 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Registered dimensions (L × B × D)154.0 ft × 42.0 ft × 10.0 ft
Registered tonnagegross 543 / net 543
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderC & C MARINE AND REPAIR LLC · BELLE CHASSE, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it543 - Simplified, Gross Ton 543 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 1972 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 22
29 July 2026Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8418454
3 November 2025Deficiency Check · Periodic Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8254113
14 May 2025Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8135924
7 April 2025Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8106345
18 October 2024Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8013692
2 August 2023Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7744511
11 July 2022Cargo Tank Internal · MTSA Verification · Drydock Exam · Examination of Repairs · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7499360
27 June 2017COI Inspection · Internal Structural Exam · MTSA Verification · Cargo Tank Internal · Drydock Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6187006
7 October 2016Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6018385
26 July 2016Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5973586
19 June 2015Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5157706
18 August 2014Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4958941
25 July 2014Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4938072
7 May 2012COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4304583
7 April 2010Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3711504
9 April 2009Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3451556
6 June 2008Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3228805
14 May 2008Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3207547
24 April 2008Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3226078
26 October 2007Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3087766
22 August 2007Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3035732
16 April 2007Cargo Tank Internal · Administrative Inspection · COI Inspection · MTSA Verification · Initial Construction-Excluding Oversight · Construction Oversight · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2909012
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 November 2025Resolved
EACH CARGO TANK OF A TANK BARGE MUST HAVE ONE OF THE FOLLOWING LIQUID OVERFILL PROTECTION ARRANGEMENTS: A SYSTEM MEETING THE REQUIREMENTS OF 46 CFR 39.2007, HIGH LEVEL AND TANK OVERFILL ALARMS. MI WAS UNABLE TO TEST ANY OF THE ALARMS DUE TO A MALFUNCTION OF THE SYSTEM.
46 CFR 39.2009(a)(1)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 19 November 2025
Resolution: MI's attended and verified operation of alarms.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 18 October 2024Resolved
No person may use any equipment listed in paragraph (c) of this section for transfer operations unless the vessel or facility operator, as appropriate, tests and inspects the equipment. The frequency of the tests and inspections required by this section must be: Each vapor hose, vapor collection arm, pressure or vacuum relief valve, and pressure sensor is tested and inspected for vessels annually, or as part of the biennial and mid-period inspections. MI observed no available valid records or indication of cargo system pressure vacuum relief valve testing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2024
Resolution: Received, reviewed and accepted proper documentation from Industrial [name withheld] stating the deficiency was rectified. PV relief valve was tested and found in good condition on 22OCT2024.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 18 October 2024Resolved
On a tank barge, each cargo tank must be equipped with an overfill device that meets the requirements of
46 CFR 39.2009 (a)(1). MI unable to witness operational testing of audible and visual alarm indicators of high/overfill alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2024
Resolution: Received, reviewed and accepted video evidence from vessel rep stating the deficiency was rectified. Tested audible and visual alarms for overfill/high level alarms in video, all sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 18 October 2024Resolved
Vapor piping systems and pressure vacuum valves that are used for polymerizing cargoes must be inspected internally at least annually. MI unable to safely inspect vapor piping during annual inspection as both end plates were not removed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2024
Resolution: Received, reviewed and accepted video from vessel rep demonstrating the deficiency was rectified. Both plates on the vapor line were open and free and clear of any debris or obstruction.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 18 October 2024Resolved
No person may use any equipment listed in paragraph (c) of this section for transfer operations unless the vessel or facility operator, as appropriate, tests and inspects the equipment. The frequency of the tests and inspections required by this section must be: for vessel annually or as part biennial and mid-period inspections. MI observed no documentation for 01 cargo hose testing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2024
Resolution: Received, reviewed and accepted proper documentation from vessel rep stating the deficiency was rectified. Cargo hose 1097738-1 was tested by Blue Water Gasket Co. on 26SEP2024. Documentation accepted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 October 2024Resolved
No extensive alterations involving the safety of a tank vessel either in regard to hull or machinery shall be made without the approval of the Commandant. Before such alterations are carried out, copies of plans and specifications in triplicate for the work involved shall be forwarded to the Officer in Charge, Marine Inspections. Two 5,000 gallon potable water tanks are mounted on wooden blocks on board tank barge, with no documentation of approval from USCG. Vessel to submit plans of modifications to MSC for approval within 7 days and provide proof of submission to Sector New Orleans. Vessel to include all changes to machinery, structure, outfitting, and equipment that affect the lightship parameters referenced in MSC approval modifications letter C1-1604492, dated December 29, 2016. Deficiency considered rectified upon receipt of MSC approval letter. 46 CFR 31.10-25
Action required: 705 - Other - as specified
Due 7 November 2024
Resolved 30 December 2024
Resolution: Vessel received MSC approval letter
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 August 2022Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward....and is at least 1 inch long. it must be located at the top of the flange face, midway between boltholes, and in line with the bolthole pattern. The stud on the vapor line was pushed in, and in the wrong location. Replace stud and spool piece prior to cargo operations requiring use of the VECS system.46CFR39.2001(j)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 11 August 2022
Resolution: Received satisfactory photo evidence of new stud and spool piece replacement.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 August 2022Resolved
The last 1 meter of vapor piping upstream of the vessel vapor connections and each end of the vapor hose must be marked in accordance with this cite. There were no markings on the vapor pipeline. Paint and stencil the appropriate markings prior to cargo operations requiring use of the VECS system. 46CFR39.2001(h)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 August 2022
Resolution: Received satisfactory photo evidence of newly painted and labled VECS line.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 August 2022Resolved
A pressure gage shall be installed at each pump discharge, and it shall be located at a point visible with respect to the pump controls. Pressure gauge on cargo pipe is broken and illegible. Replace gauge prior
to cargo operations.46CFR32.50-5
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 11 August 2022
Resolution: Received satisfactory photo evidence of newly replaced pressure gauge.
Wiring Harness on Prime Mover is not intrinsically safe, explosion proof, or purged and pressurized for a Class I Div I area. Ref D8(dp) Policy Letter 02-2007 CH1. Barge is allowed to operate until Aug 08 per policy ltr.
Due 1 August 2008
Resolved 5 November 2010
Resolution: Compliance date postponed to First d/d after 01NOV11 but no later than 01NOV2015
12 March 2013Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4548604
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
SMI 572 (2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.