SFL CONDUCTOR
SFL CONDUCTOR is a 2006 freight ship. The Coast Guard has recorded 27 inspections since 2007, most recently in July 2026, along with 4 deficiencies and 6 operational controls.
Records from 2007 to 2026. Most recent: operational control imposed, 31 July 2026.
- Built
- 2006
- Last inspected
- 31 July 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9293909 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
5LFR3
870441
Flag
LIBERIA
—
Maury page id
psix-870441
Inspections, by type
…with no type recorded7
Years with a record
14 calendar years (2007–2026)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it60118 - Convention (Subpart B), Gross Ton
18543 - Convention (Subpart B), Net Ton
17709 - Dead Weight, Ton
34574 - Displacement, Ton
18543 - Convention (Subpart B), Net Ton
17709 - Dead Weight, Ton
34574 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 27
31 July 2026
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8451409
30 July 2026
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8450667
27 July 2026
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8447806
6 July 2026
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8430437
29 May 2026
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8383368
10 March 2026
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8320985
23 October 2025
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8255555
11 March 2025
PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8087847
29 August 2024
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7989234
18 April 2024
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7896835
13 December 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7838435
5 November 2023
PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7820303
23 October 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7812938
8 May 2023
PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7680054
14 June 2022
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7471106
8 December 2021
PSC B · MARPOL Annex VI Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7364450
25 March 2021
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7162958
5 August 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6762102
11 May 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6143171
10 January 2012
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4222318
29 December 2011
ISPS II Exam · Ballast Water Examination · Deficiency Check · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4215480
15 September 2010
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3850576
2 July 2009
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3514483
8 March 2008
Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3158305
20 January 2007
PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2857867
20 January 2007
Type not recorded
No type recorded · Station Mayport · USCG Southeast District (CGD-SE) · Activity 2859070
16 January 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2856735
Deficiency record · 4
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 5 November 2023
Resolved
The company should establish procedures, plans, and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of personnel, ship, and protection of the environment.
The Vessel/Company currently does not have any procedures regarding protection of vehicle batteries, particularly electric vehicles (EV’s) from short circuit. Neither the vessel’s SMS or charterer has provided any guidance on stowage, condition, (batteries connected/disconnected, charged/uncharged, etc) of the batteries.
Recommend an internal audit of vessel’s SMS focused on cargo to be conducted within 90 days.
Engineering › Steering Gear System › Pump
Issued 29 December 2011
Resolved
In areas where navigation demands special caution, ship shall have more than one steering gear unit in operation when such units are capable of simultaneous operation. Vessel number 2 pump was unable to be operated while conducting steering tests during PSC exam. System overloaded when power was transferred to the number 2 steering pump, system is inoperable. SOLAS 74/09 CH. V Reg.25 17C
Engineering › Steering Gear System › Pump
Issued 29 December 2011
Resolved
Hydraulic power -operating steering gear shall be provided with a fixed storage tank having sufficient capacity to recharge at least one power actuating system including the reservoir, where the main steering gear is required to be power-operated. Reservoir tank supplying the hydraulic steering system does not have sufficient hydraulic fluid to recharge the hydraulic steering system.
Construction/Loadline › Markings › Tropical Load Line
Issued 29 December 2011
Resolved
The following load line shall be used, the tropical load line indicated be the line marked T. Tropical hull marking indicated with a V does not match ICLL certificate. ICLL Annex 1 CH. 1 Reg. 6.2.D
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.