MILTIADES II

MILTIADES II is a 2006 freight ship. The Coast Guard has recorded 5 inspections since 2017, most recently in July 2019, along with 9 deficiencies and 1 operational control.

Records from 2017 to 2019. Most recent: operational control imposed, 2 July 2019.

Built
2006
Last inspected
2 July 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 July 2019
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2017–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9300831
870571
Flag
LIBERIA
Maury page id
psix-870571

Documentation record

Tonnage as PSIX records it19971 - Convention (Subpart B), Gross Ton
10477 - Convention (Subpart B), Net Ton
38557 - Displacement, Ton
30535 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

2 July 2019 Ballast Water Examination · PII Safety Exam · Deficiency Check · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6733104
31 March 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6382430
30 March 2018 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6381967
22 November 2017 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6315435
21 November 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6307333

Deficiency record · 9

11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 July 2019 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use [20.2]. Rescue boats should be stowed in a continuous state of readiness for launching in not more than five minutes [14.1]. At approximately 1145 local time, PSCO asked to witness operational test of rescue boat engine. Crew could only start rescue boat using ether and rescue boat engine would not run for more than 5 seconds after start. At 1430 local time, rescue boat engine remained inoperable. PSCO observed crew rebuilding the carburetor and replacing the spark plugs in an attempt to bring engine to operational status. 74 SOLAS (14) III/20.2 74 SOLAS (14) III/14.1 30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 6 July 2019
Resolution: Received ABS Class Report attesting to the corrective maintenance and full operation of the vessel's rescue boat.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 2 July 2019 Resolved
The Company should ensure that inspections are held at appropriate intervals, any non-conformity is reported, and appropriate corrective action is taken. Company SMS manual, Chapter 9.4 requires "all employees and everyone involved in Company's activities should report any deficiency or hazard. The report may be verbal or in writing, in which case the form NCR 001...may be used." There is no objective evidence of non-conformities reported via form NCR 001, nor any other objective evidence of appropriate corrective action taken, for the operational/technical deficiencies #1 and #3-#7. Company SMS requires Form M-028b, "Planned Maintenance Program for Bridge Equipment, Life Saving Appliances and Firefighting Equipment", to be completed each month, and to "tick with the appropriate marks for each box next to the maintenance routines". Three different marks are provided for OK ([check-mark]), NOT APPLICABLE (N/A), and NOT OK (NOT OKAY). The May and June forms have "X" marks only and has zero items marked as "not ok", even though there are multiple items listed (ex: low pressure CO2, fixed dry powder) with which the vessel is not equipped. **An additional external verification of the ISM-SMC by the RO is required. 74 SOLAS (14) IX/3.1 REF ISM Code/10.2 30abc
Action required: 30 - Ship detained
Resolved 6 July 2019
Resolution: Received Lloyd's Register SMS Audit results and notes which addressed all ISM items listed in the deficiency and corrective and preventative measures to ensure compliance. LR recommends a future ISM audit within three months for follow ups.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 July 2019 Resolved
The following structural fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions [II-2/14.2.1.1]. When a fixed gas fire-extinguishing system is used, openings which may admit air to, or allow gas to escape from, a protected space shall be capable of being closed from outside the protected space [II-2/10.4.2]. Doors to purifier room are "A" class doors per vessel's Fire Control Plan. Aft "A" class door frame found to be holed, compromising the integrity of the "A" class division. Additionally, purifier room is protected by fixed CO2 fire-extinguishing system capable of being actuated separately from main engine room fixed CO2 system. PSCOs observed multiple openings (ex: cable entrances) in purifier room boundary capable of admitting air or allowing CO2 to escape. 74 SOLAS (14) II-2/14.2.1.1 74 SOLAS (14) II-2/10.4.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 July 2019
Resolution: Received ABS Class Report attesting to corrective maintenance and subsequent integrity of purifier room fire boundaries and firefighting CO2 system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 July 2019 Resolved
The purpose of this regulation is to the prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids [II-2/4.1.1]. PSCOs observed excessive fuel oil leaking on main engine from the area of the fuel injectors. PSCOs observed ad-hoc arrangement attempting to fairlead and collect leaking fuel oil into bucket via flexible hose. 74 SOLAS (14) II-2/4.1.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 July 2019
Resolution: Received ABS Class Report attesting to the removal of the unapproved hose and bucket installation as well as the re-tightening of all M/E components that were leaking.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 2 July 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Sea chest valve found with damaged remote-operated gear assembly. The fractured housing was temporarily repaired by securing with lock wire. 74 SOLAS (14) I/11 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2019
Resolution: Class surveyor attested to temporary repairs involving a welded handle and spindle.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 July 2019 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Emergency switchboard found to have electrical cable connected through spare breaker and exiting through front of switchboard. 74 SOLAS (04) II-1/45.1.3 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2019
Resolution: Crew removed the electrical cable and it is no longer connected to the switchboard. Removal verified by class.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 July 2019 Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. PSCOs observed hold-back device on two self-closing doors between officers' mess and galley, and two additional self-closing doors between engine room and aft steering. All 4 doors are noted as self-closing on vessel's Fire Control Plan. 74 SOLAS (14) II-2/9.4.2.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 July 2019
Resolution: Received ABS Class Report attesting to the removal of all hold backs.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 21 November 2017 Resolved
FIRE ALARM PANEL IN ENGINE CONTROL ROOM DOES RECORD FIRE ALARMS. SOLAS 09 CONS II-2 REG 14.2.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2017
Resolved 30 March 2018
Resolution: Received Class Report attesting to repairs made to the Automation alarm monitoring system and feed from the fire detection system. Completed testing and considered satisfactory.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 21 November 2017 Resolved
HEAT DETECTION ALARM ABOVE #3 GENERATOR WAS TAPED TOGETHER AND DID NOT WORK WHEN TESTED. SOLAS 09 CONS II-2 REG 14.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 November 2017
Resolution: Received, reviewed and accepted Class report from ABS satisfying the requirement. Ship’s crew changed out old detector with spare. Tested satisfactory.