psix-870838

Inspections, by type

…with no type recorded5
…past their stated due date1
Years with a record 18 calendar years (2007–2026)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)228.0 ft × 54.0 ft × 18.0 ft
Registered tonnagegross 1,740 / net 1,191
ITC dimensions (L × B × D)228.0 ft × 54.0 ft × 18.0 ft
ITC tonnagegross 2,383 / net 714
BuilderLEEVAC INDUSTRIES LLC · JENNINGS, LA, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 February 2026 · expires 31 March 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1740 - Regulatory (Subpart C or D), Gross Ton
2383 - Convention (Subpart B), Gross Ton
714 - Convention (Subpart B), Net Ton
2387 - Dead Weight, Ton
1191 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE3118MMSI 367334320 · active · compulsorily equipped · granted 6 December 2017, expires 29 January 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 47

18 March 2026 ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8313573
22 January 2026 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8300082
8 April 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8108371
16 January 2025 Annual Inspection · MTSA/ISPS Verification · ACP Handover Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8064359
6 March 2024 MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7873770
1 March 2024 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7872816
1 March 2024 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7877892
8 January 2024 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7846797
22 June 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7721056
31 March 2023 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7660575
6 February 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7632707
3 November 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7588565
9 February 2022 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7393261
20 August 2021 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7292259
20 April 2021 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7178884
15 April 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7175526
15 March 2021 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7156232
14 January 2020 Annual Inspection · MARPOL Annex VI Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6888892
7 January 2020 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6884503
28 March 2019 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6651150
20 December 2018 MTSA/ISPS Verification · SIP Inspection/Audit · MARPOL Annex VI Survey · Administrative Inspection · MARPOL Annex I Examination · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6593580
21 September 2018 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6545678
12 September 2018 Internal Structural Exam · Administrative Inspection · Hull Examination · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6539179
2 March 2018 MARPOL Annex VI Survey · SIP Initial Entry · MTSA/ISPS Verification · MARPOL Annex I Examination · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6365816
6 November 2017 Commercial Dive Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6301568
21 March 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6109790
27 September 2016 Internal Structural Exam · Cargo Tank Internal · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6010356
31 August 2016 Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5989060
22 August 2016 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5983138
18 July 2016 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5945158
20 June 2016 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5913217
1 April 2016 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5845325
16 March 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5834636
13 January 2016 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5797233
15 December 2015 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5781876
20 August 2015 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5227728
31 July 2015 Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5208594
27 October 2014 Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5013127
22 October 2014 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5010344
12 May 2014 Plan Review (Other than "T") · Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4856465
18 March 2014 Administrative Inspection · Plan Review (Other than "T")
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4818037
20 June 2012 Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4350266
5 January 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3920969
4 January 2010 SIP Inspection/Audit · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3657187
19 February 2009 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3420950
17 October 2007 Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3077885
20 September 2007 Initial Certification · Deficiency Check · MTSA Verification · Ballast Water Examination · Construction Oversight · Inclining Experiment
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3063028

Deficiency record · 19

09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 18 March 2026 No resolution recorded
Video and audio surveillance equipment must be placed in passageways into which doors for staterooms open. Signage must be posted clear and conspicuous notifying the crew of video and audio surveillance equipment. PAM installations for 3rd party contractors did not have cameras or signage in place for the passageways leading into the berthing spaces. 705 - Vessel will be allowed to continue operations until 09JULY2026 at which point berthing for all personnel onboard will be restricted to those areas that comply with 46 U.S.C 4901
Action required: 705 - Other - as specified
Due 9 July 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 March 2024 Resolved
2.5'' fire hoses may replaced by two (02) 1.5'' fire hoses on a wye connection. Only one (01) 1.5'' fire hose is present on exterior fire stations.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 8 March 2024
Resolution: Received email with photos of two 1.5'' hoses on each of the exterior stations.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 March 2024 Resolved
Master shall ensure the vessel's firefighting equipment is ready for use. A fire extinguisher had an unserviceable hose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 March 2024
Resolved 6 March 2024
Resolution: Replaced extinguisher with a serviceable one.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 6 March 2024 Resolved
Each opening in a watertight bulkhead must have a means to close it watertight. A cable penetration was not watertight.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 6 March 2024
Resolved 6 March 2024
Resolution: Crew installed new watertight cable penetration.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 February 2022 Resolved
In the event of alterations involving the safety of the vessel, the applicable plans shall be submitted for approval. (04) PAM's installed on the back deck have not been reviewed by the Marine Safety Center. Submit to the Marine Safety Center to be verified.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2022
Resolved 1 March 2022
Resolution: Received fwd MSC letter from vsl rep that (04) PAMS were verified.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 February 2022 Resolved
The general construction of the vessel shall be such to minimize fire hazards. Stbd side lowver vent hatch gasket missing not making a proper seal. Replace gasket.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2022
Resolved 11 February 2022
Resolution: Replaced lowver vent hatch gaskets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 February 2022 Resolved
Each vsl must carry approved life buoys. Starboard life buoy found to be not serviceable. Replace life buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2022
Resolved 11 February 2022
Resolution: Renewed Lifebuoy
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2021 Resolved
Non-conducting deck coverings must be installed at front & rear of switchboard and must extend the entire length of the operating space. Switchboard in generator flat was missing non-conductive mat in rear access. Vessel shall install required matting.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2021
Resolved 15 March 2021
Resolution: Vessel installed required Mat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 January 2020 Resolved
FUEL OIL RETURN HOSES ON THE #2 SSDG AND THE STBD MAIN DIESEL ENGINE ARE IN QUESTIONABLE CONDITION. RENEW BOTH HOSES IN ACCORDANCE WITH REGULATION
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2020
Resolved 21 January 2020
Resolution: Fuel/Oil hoses on the #2 SSDG and STBD Main diesel engine have been properly renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 January 2020 Resolved
LIGHTING PANEL L-4 HAS AN OPENING IN WAY OF BREAKERS. BLANK OFF SPACE PROPERLY TO PREVENT ACCIDENTAL SHOCK.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2020
Resolved 21 January 2020
Resolution: Lighting panel L-4 open circuit has been covered with the appropriate blank to prevent accidental shock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 January 2020 Resolved
WATERTIGHT ACCESSES AT THE FOLLOWING LOCATIONS HAVE THE INPROPER WEATHERTIGHT GASKET. THE GASKET MATERIAL MUST BE SUITABLE TO MEET THE INTENTIONS OF WATERTIGHT: BOTH PORT AND STDB ENGINEROOM ESCAPE HATCHES, BOTH PORT AND STBD QAWTD TO THE ENGINEROOM.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 January 2020
Resolved 14 January 2020
Resolution: RENEWED WITH PROPER GASKET.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 January 2020 Resolved
THE FOLLOWING LIFE RINGS HAD DRY ROTTED AND CRACKED INSPECTION PLUGS. THE PLUGS MUST BE MAINTAINED FOR WATERTIGHT INTEGRITY: STBD O2 DECK, PORT O1 DECK AND AFT MAIN DECK.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 January 2020
Resolved 14 January 2020
Resolution: LIFE RINGS RENEWED.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 January 2020 Resolved
A PIN HOLE OPENING IN THE OVERHEAD AFT STEERING COMPARTMENT TO THE MAIN DECK WAS FOUND. VESSEL TO EFFECTIVELY MAKE REPAIRS BY WELDMENT IN ORDER TO MAINTAIN STRUCTURAL/WATERTIGHT INTEGRITY.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2020
Resolved 21 January 2020
Resolution: The pin hole on the centerline main deck leading to overhead of the aft steering compartment has been welded closed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 January 2020 Resolved
ONE OF THE SCBA MASKS HAS MISSING OR INEQUIPPED STRAPS. RENEW MASK OR STRAPS IN ORDER TO BRING IT IN COMPLIANCE WITH REGULATIONS.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2020
Resolved 21 January 2020
Resolution: The SCBA mask that had damaged straps has been replaced with a mask in good order.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 January 2020 Resolved
THE CO2 ENXTINGUISHER FOR PAINT LOCKER HAS A DRY ROTTED HOSE. RENEW EXTINGUISHER OR HOSE IN ACCORDANCE WITH APPLICABLE REGULATIONS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2020
Resolved 21 January 2020
Resolution: The C02 extinguisher for the paint locker dry rotted hose has been replaced with a new hose.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 14 January 2020 Resolved
THE RESCUE BOAT HAS DOT APPROVED TAPE AS RETRO. VESSEL TO RENEW AND PROVIDE SOLAS APPROVED TYPE II TO BRING IN TO COMPLIANCE WITH APPLICABLE REGULATION.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2020
Resolved 21 January 2020
Resolution: The rescue boat DOT tape has been replaced with the approved SOLAS tape.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 October 2014 Resolved
Rox Blox installation newly installed modular workspace installed improperly.
Action required: 705 - Other - as specified
Resolved 28 October 2014
Resolution: rox blox installation made properly.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 18 March 2014 Resolved
Waiting on ABS structural approval and MSC approval for Portable quarters/work vans onboard.
Action required: 705 - Other - as specified
Resolved 18 March 2014
Resolution: Vessel received approval letters from ABS and MSC for the portable quarters/work vans.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 18 March 2014 Resolved
Starboard portable quarter/work van is missing a portable CO2 extinguisher.
Action required: 705 - Other - as specified
Resolved 18 March 2014
Resolution: Vessel installed portable CO2 extinguisher.

Casualty record · 1

1 March 2024Routine · role: Involved in a Marine Casualty · activity 7877892
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.