← All vessels
NANUQ
Industrial Vessel · Miscellaneous Vessel class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named NANUQ
NANUQ is a 2007 industrial vessel. The Coast Guard has recorded 22 inspections since 2007, most recently in October 2025, along with 5 deficiencies.
Records from 2007 to 2025. Most recent: inspection, 28 October 2025.
- Built
- 2007
- Last inspected
- 28 October 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1195538
9382841 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDQ5468
870868
Flag
UNITED STATES
338361000
Maury page id
psix-870868
Inspections, by type
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.
Documentation record
Registered dimensions (L × B × D)279.6 ft × 60.0 ft × 24.0 ft
Registered tonnagegross 3,575 / net 1,072
ITC dimensions (L × B × D)279.6 ft × 60.0 ft × 24.0 ft
ITC tonnagegross 3,575 / net 1,072
BuilderNORTH AMERICAN FABRICATORS LLC · HOUMA, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionCombination Types
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 22 July 2026 · expires 31 August 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3575 - Convention (Subpart B), Gross Ton
1072 - Convention (Subpart B), Net Ton
1072 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ5468MMSI 338361000 · active · compulsorily equipped · granted 8 August 2025, expires 8 August 2035
WDD7327MMSI 366284000 · expired · compulsorily equipped · granted 4 May 2007, cancelled 8 July 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
28 October 2025
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8260098
2 January 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8056710
24 July 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7965918
23 August 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6249744
11 March 2016
Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5831713
16 October 2015
Examination of Repairs · Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5746396
13 August 2014
Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4952545
6 July 2012
Deficiency Check · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 4369810
29 June 2012
Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4361519
24 May 2012
ACP COI Oversight
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4327917
15 February 2012
ACP Periodic Oversight
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4245834
13 December 2010
Administrative Inspection
Administrative · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3910032
9 March 2009
ACP Annual Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3422451
16 July 2008
MTSA Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3269464
24 June 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3246170
18 December 2007
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3117370
19 September 2007
In-Service Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3061560
23 July 2007
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3006066
21 May 2007
Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 2936479
18 May 2007
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 2933726
9 May 2007
Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 2926401
18 January 2007
MTSA/ISPS Verification · Welding Related Inspections Qualification Testing · Initial Construction-Excluding Oversight · ACP COI Oversight · Initial Certification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2858169
Deficiency record · 5
Electrical › Electric Generation Source (service) › Generator
Issued 19 October 2015
Resolved
Crew found air leak in aftercooler on FWD generator; vessel to install new aftercooler at next port of call (Dutch Harbor, AK); prove proper operation of FWD generator after new aftercooler is installed.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 24 May 2012
Resolved
Remove all paint from air receiver data plates and label/tag relief pressures on relief valves.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 24 May 2012
Resolved
Replace coolant hose on aft generator outboard. The hose jacketing was dry-rotting off of the hose.
Electrical › Electrical Distribution System (service) › Cable
Issued 24 May 2012
Resolved
Install metal embedded hangers at a distance not greater than 24" in overhead wiring on the outboard side of por main engine.
Lifesaving › Immersion Suits › General
Issued 24 May 2012
Resolved
Whistles on a good percentage of the vests were of the cork ball type. Replace with non-cork type or non/ball type personal whistles.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.