Records from 2007 to 2012. Most recent: inspection, 15 February 2012.
Documentation record
Tonnage as PSIX records it444 - Convention (Subpart B), Gross Ton
513 - Displacement, Gross Ton
201 - Dead Weight, Gross Ton
93 - Regulatory (Subpart C or D), Gross Ton
133 - Convention (Subpart B), Net Ton
63 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
15 February 2012
Administrative Inspection · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4245220
25 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4231365
28 July 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3547785
28 April 2009
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3462788
2 December 2008
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3374915
10 June 2008
MTSA/ISPS Verification · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3232951
31 March 2008
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3174768
24 March 2008
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3174746
24 October 2007
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3086266
10 October 2007
Deficiency Check · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3076686
27 September 2007
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3067643
19 September 2007
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3064954
10 September 2007
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3054473
3 April 2007
Administrative Inspection · Internal Structural Exam · Inclining Experiment · MTSA Verification · Hull Examination · Initial Certification · Construction Oversight · Plan Review "T" Boat
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2900778
8 March 2007
Plan Review "T" Boat
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 2886305
Documentation › Certificates/Documents › IOPP Certificate
Issued 10 June 2008
Resolved
Vessel is a SOLAS vsl and needs IOPP, GMDSS, OWS and other required SOLAS items before vlc can depart on an international voyage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2009
Resolved 27 June 2009
Resolution: Vsl not travelling internationally
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 20 June 2007
Resolved
Provide access to the bulkhead valve for the sewage drain of the Main Deck Head. Valve is to be operable from the Main Deck or have immediate access IAW 46 CFR 182.720(d)(1)(ii)(C). Properly label the access location. Requirement is to be completed to the satisfaction of Officer in Charge, Marine Inspections - Sector New Orleans.
Due 31 August 2007
Resolved 31 August 2007
Resolution: Access provided and properly labeled.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 7 May 2007
Resolved
Re-submit Drawing CB-170-A-436, Rev 0, with 'as-built' changes reflected, for approval. (Changes to drain and thru-hull penetration locations.)
Due 7 June 2007
Resolved 30 May 2007
Resolution: Rev 1 of the drawing was approved by MSC Letter E1-0701707, dated 29May07.
Accommodation/Occupational Safety › Potable Water System › General
Issued 7 May 2007
Resolved
Re-submit Drawing CB-170-A-437, Rev 1, with 'as-built' changes reflected, for approval. (Changes in equipment locations/arrangement.)
Due 7 June 2007
Resolved 6 June 2007
Resolution: Rev 1 of the drawing was approved by MSC Letter E1-0701760, dated 05Jun07.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 May 2007
Resolved
Re-submit Drawing CB-170-A-438, Rev 0, with 'as-built' changes reflected, for approval. (Approved plan calls for copper nickel piping - brass is installed.)
Due 7 June 2007
Resolved 30 May 2007
Resolution: Rev 1 of the drawing was approved by MSC Letter E1-0701707, dated 29May07.
Engineering › Thrusters › Piping
Issued 7 May 2007
Resolved
Re-submit Drawing CB-170-A-439, Rev 1, with 'as-built' changes reflected, for approval. (Approved plan calls for stainless steel piping - brass is installed.)
Due 7 June 2007
Resolved 30 May 2007
Resolution: Rev 2 of the drawing was approved by MSC Letter E1-0701707, dated 29May07.
Engineering › Compressed Air System (start air) › Piping
Issued 7 May 2007
Resolved
Re-submit Drawing CB-170-A-440, Rev 1, with 'as-built' changes reflected, for approval. (Approved plan calls for copper tubing to horn - truck hose (plastic tubing) is installed.)
Due 7 June 2007
Resolved 30 May 2007
Resolution: Rev 2 of the drawing was approved by MSC Letter E1-0701707, dated 29May07.