Records from 2012 to 2025. Most recent: inspection, 7 October 2025.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 October 2025
Resolved
When a marine employer determines that a casualty or incident is, or is likely to become, an SMI, the marine employer must ensure that the following alcohol and drug testing is conducted:(a) Alcohol testing. (1) Alcohol testing must be conducted on each individual engaged or employed on board the vessel who is directly involved in the SMI. Vessel did not have required alcohol testing equipment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2025
Resolved 5 November 2025
Resolution: testing equipment obtained.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 October 2025
Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Vessel does not have a log for the required monthly test.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2025
Resolved 5 November 2025
Resolution: Log created.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 October 2025
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Storage container not properly logged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2025
Resolved 5 November 2025
Resolution: container properly labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2025
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either:(1) A pressure type connector on each conductor;(2) A solder lug on each conductor;(3) A splice made with a pressure type connector to a flexible lead or conductor; or(4) A splice that is soldered, brazed, or welded to a flexible lead or conductor.MI found several unapproved wire twist on connectors for the stairwell lights on the STBD side upper deck and port side lower stair wells.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2025
Resolved 5 November 2025
Resolution: identified cables properly spliced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions.
Battery in the engine room aft port side, has excessive corrosion on one battery terminal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 10 April 2025
Resolution: Battery replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2025
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. multiple batteries in the engine room have wing nuts on terminals post.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 10 April 2025
Resolution: wing nuts removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 April 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. MI observed missing drain plugs on the port main fuel filter under the drain valves.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 10 April 2025
Resolution: drain plugs installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 October 2024
Resolved
A hatch cover must:(1) Have securing devices.
Several hatch covers on board were observed to be without their intended securing devices.
46 CFR 116.1160(b)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2024
Resolved 18 November 2024
Resolution: Fabricated new securing devices and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 October 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. In storage area for life jackets, no means were observed to separate adult from child life jackets.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2024
Resolved 18 November 2024
Resolution: Labels installed to separate adult and child life jackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2024
Resolved
Every portable fire extinguisher must be supplied with a suitable bracket which will hold the extinguisher securely in its stowage location on vessels or boats, and which is arranged to provide quick and positive release of the extinguisher for immediate use. During vibration testing, the extinguisher must be tested in the marine bracket.
Spare fire extinguishers on board were observed without mounts/brackets.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2024
Resolved 18 November 2024
Resolution: SPare fire extinguishers placed in mounting brackets
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 23 October 2024
Resolved
At each inspection for certification and at every other vessel inspection spaces may be examined to determine that they are serviceable and in a sanitary condition.
Electrical fitting preventing sewage from leaking out of MSD tank found broken and allowing leaking into bilge.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2024
Resolved 18 November 2024
Resolution: Leaking fittings repaired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. The following non-conformities were identified:
- Multiple beaker panels had missing breakers/blanks that left live electrical components exposed
- Refrigeration unit had an electrical pressure switch with missing cover leaving electrical components exposed
- Port and starboard A/C spaces by refrigeration compressor and refer by evaporator had covers for refrigeration controls ajar leaving electrical components exposed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2024
Resolved 18 November 2024
Resolution: All electrical repairs made
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2024
Resolved
Each ungrounded system must be provided with a suitably sensitive ground detection system, located at the respective switchboard, that provides continuous indication of circuit status to ground with a provision to momentarily remove the indicating device from the reference ground. Negative ground was detected in ungrounded system.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2024
Resolved 3 February 2025
Resolution: Ground detection system repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2024
Resolved
For portable fire extinguishers, the inspections, maintenance procedures and hydrostatic pressure tests required by NFPA 10, with the frequency specified by NFPA 10. In addition, carbon dioxide and halon portable fire extinguishers must be refilled when the net content weight loss exceeds that specified for fixed systems by Table 115.810(b). The owner or managing operator shall provide satisfactory evidence of the required servicing to the marine inspector. Operator was unable to provide satisfactory evidence of required monthly servicing
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2024
Resolved 18 November 2024
Resolution: Monthly fire extinguisher inspection program put in place
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 October 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct operational test of electrical apparatus, which operates as part of or in conjunction with a fire detection or alarm system installed on board the vessel. Fire detection panel shows trouble in MSD space.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2024
Resolved 18 November 2024
Resolution: Trouble in fire detection panel resolved.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 July 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Received report from vessel rep that the illuminated sign for the vessel's name on the starboard side had a small electrical fire. Vessel must submit investigation findings and repair electrical componentry to satisfactory condition.
46 CFR § 120.200(b)
Action required: 705 - Other - as specified
Resolved 23 October 2024
Resolution: System disconnected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 August 2023
Resolved
A hatch exposed to the weather must be watertight. Renew knife edge to maintain watertight integrity. Provide repair plan for approval.
46 CFR 116.1160(a)
16c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 August 2023
Resolved 5 June 2024
Resolution: Received proof of repairs IAW previously MI approved repair proposal. Uploaded to documents.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 August 2023
Resolved
All escape hatches must be marked on both sides clearly. "emergency exit keep clear". Label escape hatch for the ER in deck 1 aft space.
46 CFR 122.606
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2023
Resolved 24 August 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 August 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Replace cover on AC unit in aft steering.
46 CFR 120.200(c)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2023
Resolved 24 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 August 2023
Resolved
Exhaust piping must... prevent backflow of water. Renew pinholes where exhaust piping meets side shell. Provide repair plan.
46 CFR 119.430(c)
16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2023
Resolved 24 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2022
Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant OCMI.
The raw water piping for the HVAC units in the operational space was identified as being corroded, damaged, and leaking.
Provide proposal to repair or replace. Correct within 7 days.
46 CFR 119.700
Action required: 705 - Other - as specified
Due 14 October 2022
Resolved 17 October 2022
Resolution: Vessel installed new piping.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 November 2020
Resolved
Maintain system in accordance with maintenance instructions in system manufacturer's manual. 3 of 10 nitrogen bottles on the water mist system are showing 0 PSI and crew was not proficient in the use of the system to demonstrate that the system was capable of operation.
46 CFR 115.810(b)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 20 November 2020
Resolution: witnessed satisfactory test of water mist system conducted by master.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 November 2020
Resolved
Each lifejacket must be marked with Type I retroreflective material. 39 adult lifejackets and 2 child lifejackets need replacement retroreflective tape.
46 CFR 122.604(h)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2020
Resolved 20 November 2020
Resolution: lifejackets verified to have replaced retroreflective tape.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 November 2020
Resolved
Each ring life buoy must be marked in block letters with the vessel's name. Port bridge ring buoy needs replacement lettering.
46 CFR 122.604(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2020
Resolved 20 November 2020
Resolution: ring buoy lettering was observed in satisfactory condition.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 November 2020
Resolved
Each ring life buoy must be in accordance with Subchapter Q. Replace grab line on aft ring life buoy.
46 CFR 117.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2020
Resolved 20 November 2020
Resolution: grabline on aft ring life buoy was replaced satisfactorily
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 16 November 2020
Resolved
Each rescue boat must be marked with Type II retroreflective material approved in Subchapter Q. Replace retroreflective tape on rescue boat.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2020
Resolved 20 November 2020
Resolution: Rescue boat retroreflective tape replaced satisfactorily.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 November 2019
Resolved
Immediately after addressing resultant safety concerns, the owner, agent, master, or person in charge shall notify the nearest Sector whenever a vessel is involved in a marine casualty consisting of an occurrence materially and adversely affecting the vessel’s fitness for service, including fire. Failure of water heater electrical system led to a fire within the control panel. Fire was not reported and no record exists on board. 46CFR122.202(a)(4)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 14 November 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 November 2019
Resolved
Each distribution panel or switchboard must be totally enclosed. At least six distribution panels and switchboards were found with open fronts throughout the vessel. 46 CFR 120.330 (b)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 14 November 2019
Resolution: Panel Covers installed or closed to ensure safety throughout vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 November 2019
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the intended purpose. Water heater experienced short and resulted in fire, burning out wiring. Wiring was only replaced on 2 of the 6 heating elements, placing greater load than intended on the 2 replaced elements. Minor repairs were made to the electrical system but not verified by a USCG MI.
46 CFR 119.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2019
Resolved 4 December 2019
Resolution: Vessel submitted report showing newly installed heater of the same type.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 November 2019
Resolved
Each accommodation space must be fitted with a manual alarm system. The fire detection system’s notification device in crew berthing was disconnected.
46CFR118.400(e)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 14 November 2019
Resolution: General Alarm bell replaced and permanently fixed to bulkhead
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 November 2019
Resolved
A-Class bulkheads must be so constructed so that they are capable of preventing passage of smoke and flame for 1 hour. Engine room door was missing handle and latching device creating a non-smoke tight boundary. The galley’s operational office door was incapable of self-closing due to a missing closure device.
46CFR116.415(a)(2)(i)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 14 November 2019
Resolution: Doors adjusted to properly close. Handles installed on engine room door and pantry doors. Self closure apparatus installed on ships operational office
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 November 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Non-marine grade extension cords are being used throughout the vessel, including permanently installed cords in galley, on bridge, and in passenger accommodations.
46CFR120.200
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 14 November 2019
Resolution: Extension cords removed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 12 November 2019
Resolved
Exhaust gas must not leak from piping or connections. Exhaust leak found along piping in muffler room.
46 CFR 119.430(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 November 2019
Resolution: Exhaust leak repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 November 2019
Resolved
The use of twist on type wire nuts are permitted when the connection is made within an enclosure. The power supply wires for the A/C unit were connect with wire nuts outside of an electrical junction box.
46 CFR120.340(i)(1)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 14 November 2019
Resolution: Junction box installed properly to house wire connections.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 12 November 2019
Resolved
Weekly, each rescue boat must be run ahead and astern for not less than three minutes. Vessel not testing rescue boat engine weekly.
46CFR122.720(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2019
Resolved 4 December 2019
Resolution: Rescue Boat Drills being conducted.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 12 November 2019
Resolved
Sea rails must be installed on a cooking appliance. Range missing sea rails.
46 CFR 121.220(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2019
Resolved 13 January 2020
Resolution: Pictures sent in of instaled searails
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 12 November 2019
Resolved
Fire control plan must show structural fire protection boundaries. Fire control plan does not show the type and location of fire doors.
46 CFR 116.530
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2019
Resolved 26 November 2019
Resolution: Fire Control Plan sent in and verified
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 12 November 2019
Resolved
Piping must be insulated where necessary to prevent injuries. Exhaust lagging missing in muffler room over exhaust piping.
46 CFR 116.970
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 November 2019
Resolution: Lagging replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 November 2018
Resolved
Repair fuel leak on generator as discussed with MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2018
Resolution: Repaired leak, leak was engine coolant, not diesel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 November 2018
Resolved
Repair motor controller for SSDG breaker on switchboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 November 2018
Resolution: SHip has installed a new motor controller.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 14 August 2017
Resolved
Provide operable emergency lights (02-Engine Rm, 01-Galley). 46 CFR 120.432
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 28 August 2017
Resolution: tested all emergency lighting. all emergency lighting functioned as designed.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 14 August 2017
Resolved
Properly label distribution panel (P403). 46 CFR 120.330
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 28 August 2017
Resolution: distribution panel labeled properly.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 August 2017
Resolved
Re-label 03 ringbuoys (fwd bridge p/s, aft deck main & 2nd deck) 46 CFR 117.70
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 28 August 2017
Resolution: vessel name properly stenciled on all ring buoys.
Fire Fighting › Structural - A Class Divisions › Aux Spaces (little/no fire risk)
Issued 8 August 2017
Resolved
Re-stuff tube or equivalent to air handler. 46 CFR 415(a)(2)(ii)
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 28 August 2017
Resolution: tube properly stuffed and sealed.
Construction/Loadline › Hull › Stiffener
Issued 21 December 2016
Resolved
Make repairs to cracked weld starboard side forepeak as identified. 46 CFR 116.300
Action required: 705 - Other - as specified
Due 27 December 2016
Resolved 27 December 2016
Resolution: Crack was ground back, re-welded; inspected satisfactorily.
Stability › Watertight Integrity › General
Issued 21 December 2016
Resolved
Prove operation of port and starboard watertight hatches on aft deck; service closure devices. 46 CFR 116.1120
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 30 December 2016
Resolution: Watertight hatches were in good working order.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 December 2016
Resolved
Replace loose fasteners on railing leading to upper deck. Secure rail to deck meeting 46 CFR 116.900(b).
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 30 December 2016
Resolution: Railing was refastened and in good order.
Accommodation/Occupational Safety › Ventilation › General
Issued 21 December 2016
Resolved
Prove operation of power ventilation servicing muffler room. 46 CFR 116.600
Action required: 705 - Other - as specified
Due 27 December 2016
Resolved 27 December 2016
Resolution: Electrician replaced a relay in switchboard; satisfactorily inspected.
Lifesaving › Hand Flares › Expired
Issued 22 November 2016
Resolved
Replace two expired red ditress flares. -46CFR122.614
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 25 November 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 22 November 2016
Resolved
Make red flashing light on aft side of aft WTD operational. -46CFR116.1160
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 25 November 2016
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 22 November 2016
Resolved
Blank off openings in distribution panel outside galley, in engine room, and panel 247.
-46CFR120.330
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 25 November 2016
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 November 2016
Resolved
Fire door on deck 3 is not remotely releasing from magnetic hold-back. -46CFR116.435
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 6 December 2016