Records from 2007 to 2025. Most recent: inspection, 21 July 2025.
Inspection history · 39
21 July 2025
PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8186257
3 July 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7945285
18 June 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7937684
17 June 2024
PSC B · Ballast Water Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7929957
16 November 2023
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7825708
8 February 2023
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7633781
7 February 2023
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7633519
17 January 2023
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7622346
18 March 2022
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7412124
12 April 2020
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6941347
12 April 2020
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6941538
1 April 2020
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6934180
30 September 2019
Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6820466
23 September 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6819128
5 September 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6804349
2 September 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6801857
1 July 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6732160
28 June 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6728668
5 September 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6525252
17 April 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6126156
16 July 2015
COE-Offshore
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5186437
11 May 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4878344
13 March 2014
COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4811079
12 March 2014
ISPS I Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4814652
12 March 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4814971
17 July 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4376593
25 June 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4365045
10 May 2012
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4307515
19 February 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4247415
15 January 2011
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3927087
25 December 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3914095
5 November 2010
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3885545
3 October 2010
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3862045
5 September 2010
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3842238
24 March 2010
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3698170
30 May 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2946871
9 March 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2884756
10 February 2007
PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2870748
9 February 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2869938
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 17 June 2024
Resolved
Any ship of 400 Gross Tonnage and above but less than 10,000 gross tonnage shall be fitted with oil filtering equipment complying with paragraph 6 of this regulation. The Chief engineer reported that the oil content meter (OCM) is currently inoperable. PSCO verified the OCMI is not working and parts were ordered during the exam. MARPOL I/14.1 17AC
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 17 June 2024
Resolved 17 June 2024
Resolution: Vessel received dispensation from Flag to sail with equipment under certain conditions(see attachment)
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 November 2023
Resolved
The purpose of this regulation is to suppress and swiftly extinguish a fire in the space of origin. For this purpose, the following functional requirements should be met: fire-extinguishing appliances shall be readily available.
PSCO discovered 06 CO2 cyclinders with pins installed rendering cyclinders incapable of being actuated.
Corrected defiency prior to PSCO departure.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 16 November 2023
Resolved 16 November 2023
Resolution: Crew removed pins from cylcinders to ensure the CO2 system was in proper working order.
Deficiency was corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 March 2022
Resolved
07124 - The function of fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the Administration by means of equipment producing hot air at the appropriate temperature, or smoke or aerosol particles having the appropriate range of density or particle size, or other phenomena associated with incipient fires to which the detector is designed to respond. PSCO observed flame detector being tested with an unapproved lighter.
74SOLAS (CONS. 2004) II-2/7.3.2. - 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 January 2023
Resolution: Received PMS records of flame detectors. See documents.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 8 March 2007
Resolved
AIS pilot plug inop. Vessel is to submit a tech report upon completion of repairs.
Due 16 March 2007
Resolved 16 March 2007
Resolution: Recieved tech report attesting to proper repairs. Operational Control is lifted.