Records from 2008 to 2019. Most recent: inspection, 21 September 2019.
Inspection history · 17
21 September 2019
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6830134
19 August 2019
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6788209
8 February 2019
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6622690
22 August 2018
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6519588
13 August 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6510350
10 April 2017
Administrative Inspection · Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6121467
7 October 2016
Administrative Inspection · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6018157
6 September 2016
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6166279
9 June 2016
COI Inspection · Deficiency Check · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5902455
9 October 2014
Administrative Inspection · Excursion Permit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5003111
2 October 2014
Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4998604
13 February 2012
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4243536
16 November 2010
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3892806
14 November 2008
Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3363222
13 November 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3362576
1 July 2008
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3289999
25 June 2008
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3234738
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 February 2019
No resolution recorded
Demonstrate compliance with new Conditions of Operation listed on amended COI.
Action required: 17 - Rectify deficiencies prior to departure
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 September 2018
No resolution recorded
Prior to carrying passengers for hire conduct underway portion of Annual Inspection to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Construction/Loadline › Hull › Longitudinal Frame
Issued 22 June 2016
Resolved
Provide repair proposal for wasted ribs/frames IWO installed keel-coolers and fore & aft wheel wells.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2016
Resolved 23 June 2016
Resolution: Received repair proposal (see attached documentation).
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 June 2016
Resolved
Provide approved first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 28 June 2016
Resolution: Received photo showing new first aid kit is onboard.
Construction/Loadline › Hull › Hull Plating
Issued 22 June 2016
Resolved
Provide to OCMI a list of associated plans to which TD-13 is constructed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 21 July 2016
Resolution: Recieved an email outlining the plans to which TD-13 is constructed.
Stability › Incline Test › General
Issued 22 June 2016
Resolved
Verify compliance with the vessels stability letter by means of a weigh ticket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 1 July 2016
Resolution: Vessel rep submitted calculations and a weight ticket to verify compliance with stability letter.
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 June 2016
Resolved
Submit plans for all systems that have not yet been approved that utilize nonmetallic piping materials. Extended 30 days as per request.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 6 September 2016
Resolution: Received list of plans for systems that utilize non-metallic piping. Plans also submitted to MSC for review.
Engineering › Bilge Water Management System › Piping
Issued 3 October 2014
Resolved
Properly install suitable hoses for all (03) bilge piping systems on each vessel, secure with double hose clamps, and prove proper operation of removing water from each space prior to carrying passengers for hire. 46CFR182.520(f)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2014
Resolution: Vessel replaced bilge line and tested.
Documentation › Logs/Records › Drug Test Records
Issued 1 July 2008
Resolved
Serious marine incident testing policy is not in accordance with 46 CFR 4.06. Employer currently has all requirements for the FTA and needs to include requirements for the USCG.
Due 1 August 2008
Resolved 24 July 2008
Resolution: Employer updated policy to reflect serious marine incident testing in accordance with both the FTA and USCG.