Records from 2016 to 2026. Most recent: inspection, 13 January 2026.
Inspection history · 16
13 January 2026
PSC A
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8294781
4 November 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8270363
14 October 2025
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8251430
25 March 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8099740
8 March 2025
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8089926
3 May 2024
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7906296
15 November 2022
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7594604
11 October 2022
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7575146
31 March 2022
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7421700
1 December 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7360202
22 September 2021
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7314486
19 September 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7315595
17 September 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7314548
12 December 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6323238
31 October 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6298147
14 September 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6000474
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 March 2025
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. PSCO observed "A" class door in galley labeled cold provisions chamber held open with rope.
74SOLAS(04) II-2/9.4.2.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 8 March 2025
Resolution: Rope was removed from door, allowing it to close fully.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 12 October 2022
Resolved
TO ASSIST IN CASUALTY INVESTIGAITON, SHIPS, WHEN ENGAGED ON INTERNATIONAL VOYAGES, SUBJECT TO REGULATION 1.4, SHALL BE FITTED WITH A VOYAGE DATA RECORDER (VDR). VDR IS HAVING INTERMITTANT ISSUES RECRODING RADAR IMAGES.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 October 2022
Resolved 13 October 2022
Resolution: Class issued short term cargo ship safety equipment certificate to the satisfaction of USCG.
Engineering › Fuel Oil Service System › Piping
Issued 14 September 2016
Resolved
0750- Firefighting-The ignition of flammable liquids shall be provided to control leaks of flammable liquids.
Observed the top of the main engine heads (#2,3,4 & 5) leaking fuel oil. 74 SOLAS (14) II-2/4.1.1
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 September 2016
Resolution: Received class report from BV attesting to proper rectification of deficiency.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 September 2016
Resolved
1740-Pollution prevention Oil filtering equipment shall ensure that oil mixture discharge in the sea after passing through the system has an oil content not exceeding 15ppm.
Observed oil meter content not recording a log, the SIM card is selected to off.
73 MARPOL (11) ANX.1/14.6
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 September 2016
Resolution: Received class report from BV attesting to proper rectification of deficiency.