Records from 2016 to 2026. Most recent: inspection, 10 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 24
10 April 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8345956
19 February 2025
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8081669
12 February 2025
Administrative Inspection · Construction Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8078842
16 July 2024
Administrative Inspection · Construction Oversight · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7959566
8 May 2024
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7908563
5 June 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7703464
28 October 2022
Deficiency Check · Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7595707
21 April 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7435620
24 May 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7205386
20 October 2020
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7081236
27 April 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6944613
11 February 2020
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6907002
8 May 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6679823
5 November 2018
Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6575059
14 May 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6414418
19 June 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6181131
17 May 2017
Type not recorded
No type recorded · Station Pensacola · USCG Heartland District (CGD-H) · Activity 6149388
7 April 2017
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6119747
7 November 2016
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6036672
2 August 2016
Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5961551
15 June 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5910020
24 May 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5886442
11 May 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5874790
7 April 2016
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5849410
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 April 2026
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. MI found fuel tank vent piping without flame screens.
46 CFR 182.450 (e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2026
Resolved 1 June 2026
Resolution: fill/vent combo replaced with separate fill and vent system with satisfactory vent with flame screen installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 April 2026
Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI found 5 degraded life jackets on board reducing satisfactory adult life jacket count to 33. Vessel is limited to 33 total persons on board until an adult life jacket can be provided for each person on board.
46 CFR 180.71 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 June 2026
Resolution: Received evidence of new life jackets on board
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 5 March 2025
Resolved
Fuel lines must be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration. Marine inspector observed fuel line taut and impeding full movement of outboard port engine and causing the separation from its connection point on the fuel filter. Vessel shall replace fuel line that does not become taut upon engine movement.
Cite: 46 CFR 182.455(b)(3)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 March 2025
Resolution: Vessel rep procured new hose meeting CFR requirements and installed, cleared def
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2025
Resolved
A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. Marine inspector observed missing 03 appropriately sized life jackets for persons under ninety lbs. Vessel is limited to operating with only 01 child passenger until appropriately sized life jackets are placed on board.
Cite: 46 CFR 180.71(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 March 2025
Resolution: vessel rep procured 3 child sized life jackets and placed on board
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 February 2025
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Repairs or alterations that affect the safety of the vessel include, but are not limited to: steering, propulsion and power supply systems. Received report of unauthorized repair/replacement of steering rams. Upon repair completion, owner/operator to conduct sea trials in presence of Coast Guard Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2025
Resolved 19 February 2025
Resolution: Steering rams were replaced with acceptable replacements, op tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 May 2024
Resolved
A power-driven vessel underway must exhibit side lights. Port side light found non functional. Recommended continue to repair and restricted to daytime operation only until working properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2024
Resolved 20 June 2024
Resolution: Vessel Rep provided proof via eamil of funtioning nav lights, photo uploaded to documents tab.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. There was no labeling to indicate location of child life jackets. Recommended placement of placard or label indicating the location of child life jackets.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 20 June 2024
Resolution: Vessel Rep provided proof via eamil of seperation in child and adult life jackets, photo uploaded to documents tab.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2024
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. There was no physical placard available to read donning instructions. Recommended to make donning instructions available for passengers to view.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 20 June 2024
Resolution: Vessel Rep provided proof via eamil of donning instructions for life jackets, photo uploaded to documents tab.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2024
Resolved
When flexible fill piping that is a nonconductor of electricity is used, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. The fill pipe was not bonded with a grounding wire. Recommended installation of a means to bond the fill piping.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 20 June 2024
Resolution: Vessel Rep provided proof via eamil of bonding wire installation, photo uploaded to documents tab.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2024
Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Strainers must be leak free. Strainers must be the type of opening on top for cleaning screens. A drip pan fitted with flame screen must be installed under gasoline strainers. The fuel strainer did not have a metallic drip pan underneath. Recommended installation of a suitable strainer drip pan to shield the strainer from fire and impact.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 20 June 2024
Resolution: Vessel Rep provided proof via eamil of suitable fuel strainers, photo uploaded to documents tab.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 May 2024
Resolved
Each vessel must be equipped with at least two operable portable battery lights. Portable lights were not found on board. Recommended purchase of and keep on board (02) portable lights.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 20 June 2024
Resolution: Vessel Rep provided proof via eamil of two functional portable lights, photo uploaded to documents tab.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 June 2023
Resolved
Vessel missing 02 distress flares. had 04 day/night onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2023
Resolved 9 June 2023
Resolution: Photo of newly purchased, additional 03 day/night flares provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 June 2021
Resolved
Vessel must carry an approved first aid kit. Amonia inhalants are missing. Obtain current amonia inhalants.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2021
Resolved 16 June 2021
Resolution: Vessel provided nonexpired ammonia inhalants.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 March 2020
Resolved
Name of vessel and hailing port not present as required. Post name of vessel and hailing port as required -46CFR67.123(b)
For vessels having a square bow, the name of the vessel must be marked on some clearly visible exterior part of the bow in a manner to avoid obliteration. The name and hailing port must be marked on some clearly visible exterior part of the stern.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2020
Resolution: Vessel name and hailing port posted as required by 46 CFR 123(b).
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 June 2019
Resolved
Remount or label the portable fire extinguisher currently located in the head as the extinguisher is not in plain view.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 22 July 2019
Resolution: Fire extinguisher location was properly marked
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 June 2019
Resolved
Properly mount fire extinguisher at the operating station so that it cannot fall during operation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 22 July 2019
Resolution: Fire extinguisher was properly remounted at operating station
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 June 2019
Resolved
Provide updated chart, corrected through June 2019. Current chart was corrected through 2016.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 22 July 2019
Resolution: Owner provided proof of newly purchased charts
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 November 2018
Resolved
Port and starboard structural engine mount cracked. Needs to be repaired
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2018
Resolved 19 November 2018
Resolution: Port and Starboard engine mounts were welded to satisfactory fix all cracks.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 November 2018
Resolved
Port and starboard bow deck angle cracked. Needs to be repaired
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2018
Resolved 19 November 2018
Resolution: Port and Starboard bow deck angle edges were satisfactory welded to fix all broken and cracked welds
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 November 2018
Resolved
Man overboard ladder has cracked weld. Needs to be repaired
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2018
Resolved 19 November 2018
Resolution: All cracked welds were grinded out and welded so that the structural integrity was restored.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 November 2018
Resolved
Starboard running light cracked. Needs to be repaired
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2018
Resolved 19 November 2018
Resolution: New starboard sidelight was provided.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 June 2017
Resolved
New life ring need retro tape.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 19 June 2017
Resolution: Retro tape put on life ring.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 5 June 2017
Resolved
Post EAP hotline.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 19 June 2017
Resolution: Hotline posted.
Engineering › Steering Gear System › Pump
Issued 15 June 2016
Resolved
Repair/replace hydraulic steering helm pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 June 2016
Resolved 17 June 2016
Resolution: Owner replace helm pump
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 28 April 2016
Resolved
DAPI enrollment not provided for deckhand. Provide proof of DAPI enrollment for all crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 24 May 2016
Resolution: Vessel owner notified us via email deckhand is no longer employed with company so there is no need to have them on the DAPI enrollment sheet.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 April 2016
Resolved
Wiring with plastic supports. Replace with proper metallic supports.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Proper supports installed on all wiring.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 April 2016
Resolved
Port side aft bench not properly supported. Properly secure bench.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Benches secured.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 28 April 2016
Resolved
Charts and tides and currents are not up to date. Provide current charts and publications.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Updated tides and currents provided.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 28 April 2016
Resolved
Required drills not logged. Conduct man overboard and abandon ship drills and log.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Drills recorded in ship's log.
Operations/Management › Drills/Instruction › Fire
Issued 28 April 2016
Resolved
Required drills not logged. Conduct and log fire fighting drills and training.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 11 May 2016
Resolution: Drills recorded in ship's log.