NAVIOS ASTRA is a 2006 freight ship. The Coast Guard has recorded 4 inspections since 2016, most recently in August 2020, along with 4 deficiencies and 1 operational control.
Records from 2016 to 2020. Most recent: operational control imposed, 24 August 2020.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it30002 - Convention (Subpart B), Gross Ton 18486 - Convention (Subpart B), Net Ton 53468 - Dead Weight, Metric Ton 61965 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 4
24 August 2020Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7041964
24 August 2020Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7046683
16 May 2019ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6681253
14 November 2016Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6043346
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2019Resolved
The condition of the ship and its equipment shall be maintained to conform with present regulations to ensure vessel remains fit to proceed to sea without danger to the ship or persons on board. PSCO observed excessive leaks on #1 cooling water pump and reefer cooling water pump. 74 SOLAS (04) I/11
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2019
Resolved 18 May 2019
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 May 2019Resolved
The fire resistance of doors shall be equivalent to that of the division in which they are fitted... Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gas tight and self closing. PSCO observed upper escape trunk door did not self close. 74 SOLAS (04) II-2/9.4.2.1
Action required: 10 - Deficiency Rectified
Due 16 May 2019
Resolved 16 May 2019
Resolution: Fixed on the spot
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 May 2019Resolved
Stairways shall be within enclosures formed of “A” class divisions, with positive means of closure at all openings,...PSCO observed self closing door on the stairwell for A deck did not self close. 74 SOLAS (04) II-2/9.2.2.5.1
Action required: 10 - Deficiency Rectified
Due 16 May 2019
Resolved 16 May 2019
Resolution: Fixed on the spot
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 May 2019Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems & appliances. PSCO found maintenance records did not track which fire detection equipment had been tested & maintenance was not carried out in accordance with company procedures.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 16 May 2019
Resolution: Recieved class report.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.