MAURY USCG vessel records Sign in
← All vessels

CHERYL TIDE

CHERYL TIDE is a 2007 offshore supply vessel. The Coast Guard has recorded 19 inspections since 2007, most recently in November 2017, along with 47 deficiencies and 1 operational control.

Records from 2007 to 2017. Most recent: inspection, 8 November 2017.

Built
2007
Last inspected
8 November 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9452012 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDD9583
872282
Flag
UNITED STATES
368411000
Maury page id
psix-872282

Inspections, by type

…with no type recorded1
Years with a record 9 calendar years (2007–2017)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it494 - Convention (Subpart B), Gross Ton
562 - Dead Weight, Gross Ton
197 - Regulatory (Subpart C or D), Gross Ton
148 - Convention (Subpart B), Net Ton
134 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD9583MMSI 368411000 · active · compulsorily equipped · granted 27 June 2017, expires 14 September 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 19

8 November 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6303050
26 September 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6275046
15 June 2017 MARPOL Annex I Examination · Periodic Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6176314
28 March 2016 MTSA/ISPS Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 5841632
23 November 2015 Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Activities Europe · Activity 5768445
21 September 2015 Type not recorded
No type recorded · Activities Europe · Activity 5812589
9 July 2012 Administrative Inspection
Administrative · Activities Europe · Activity 4387520
8 December 2011 DAPI Audit · MTSA/ISPS Verification · Annual Inspection · Internal Structural Exam
Physical examination · Activities Europe · Activity 4164329
1 September 2010 Periodic Inspection · MTSA/ISPS Verification · DAPI Audit · Examination of Repairs · Drydock Exam · Internal Structural Exam · MARPOL Annex IV Survey
Physical examination · Activities Europe · Activity 3818993
9 December 2009 Annual Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 3661778
18 November 2008 Annual Inspection
Physical examination · Activities Europe · Activity 3352183
17 April 2008 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3186482
14 January 2008 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3130388
3 January 2008 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3139635
8 November 2007 Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3095166
29 October 2007 Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3094959
15 October 2007 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3080492
28 September 2007 Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3068337
22 June 2007 Initial Certification · MTSA/ISPS Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2970403

Deficiency record · 47

Lifesaving › Inflatable Liferafts › Servicing
Issued 26 September 2017 Resolved
Granted request to extend the annual servicing of the 04 liferafts until 29 Oct 2017.
Action required: 705 - Other - as specified
Due 29 October 2017
Resolved 16 February 2018
Resolution: Cleared
Engineering › Diesel Engine (propulsion-reduction gear) › Nozzle, Injection (fuel injection)
Issued 21 June 2017 Resolved
Vessels Port Inboard main propulsion engine would not maintain steady RPM's and was surging between 615-750 RPM's.
Condition: Improper/Lack of Maintenance
Due 29 June 2017
Resolved 29 June 2017
Resolution: Ships crew and vessel reps made adjustments to the fuel system and restored consistant engine RPM's.
Construction/Loadline › Penetrations › Weld
Issued 15 June 2017 Resolved
Crack in hull around threw hull penitration for engine exhaust. Conduct repairs and NDT additional hull penitrations for deterioation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 30 June 2017
Resolution: Received pictures and reports for damage repairs. No additional damged discovered during NTD tests.
Lifesaving › Inflatable Liferafts › Weak Link
Issued 15 June 2017 Resolved
Liferaft weak link hooked up incorrectly.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 30 June 2017
Resolution: MI's provided on the spot training with ships crew and correctly attached the liferaft in question to the painter/weak link.
Engineering › Steering Gear System › Hand Pump
Issued 15 June 2017 Resolved
Directions posted for emergency steering are confusing and incorrect for installed equipment.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 30 June 2017
Resolution: Ships crew replaced plaquarding with clear instructions.
Navigation › Collision/Grounding Avoidance › Radar
Issued 15 June 2017 Resolved
Second X Band radar inoperable.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 26 June 2017
Resolution: Corrected 26JUN17.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 15 June 2017 Resolved
Primary engineroom is equiped with both heat and smoke detectors. When tested in the presence of the attending MI the smoke detector failed to produce an alarm.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 30 June 2017
Resolution: Ships support personnel replaced the defective smoke detector and tested sat. Prior toe MI's departing vessel.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 June 2017 Resolved
Vessel reps sent out the ships Oil Content meter for Calibration. The unit was lost by KLM airlines. A replacement unit was ordered.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 30 June 2017
Resolution: Received notificaiton that the OCM was received, installed and tested.
Engineering › Steering Gear System › Pump
Issued 29 April 2016 Resolved
Stbd steering pump tube locking when maxed out.
Action required: 705 - Other - as specified
Due 29 May 2016
Resolved 10 May 2016
Resolution: Vessel provided captain attestation and a tech report stating the stb steering pump was full operational.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 29 April 2016 Resolved
Vessel needs to ensure all alarms and shutdowns are in accordance within parameters specified by the manufacture.
Action required: 705 - Other - as specified
Due 29 May 2016
Resolved 10 May 2016
Resolution: Vessel provided captain attestation and a tech report stating that all alarms and shutdowns are operational and within parameters.
Construction/Loadline › Penetrations › Pipe Flange
Issued 23 November 2015 Resolved
Repair all wasted flanges IWO all sea-valves asa discussed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2015
Resolution: Completed repairs.
Engineering › Bilge Water Management System › Valve
Issued 23 November 2015 Resolved
Repair/Replace forepeak shut-off valve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2015
Resolution: Completed.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 23 November 2015 Resolved
Repair leaking exhaust water cooling piping on #4 MDE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2015
Resolution: Completed repairs.
Electrical › Electric Supply System (service) › Cable
Issued 23 November 2015 Resolved
Properly mount and hard wire exhaust fan next to AC unit. Or remove fan and extension cord.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2015
Resolution: Fan was removed.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 1 September 2010 Resolved
Provide updated fire plans for approval. Current plans have several changes and are not approved. Item reported cleared via E-mail dated 24JAN11 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 20 November 2010
Resolved 8 December 2011
Resolution: Updated plans are onboard and posted.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 1 September 2010 Resolved
Provide company drug and alcohol program audit to local OCMI
Action required: 705 - Other - as specified
Due 20 November 2010
Resolved 20 September 2010
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 September 2010 Resolved
Replace expired eye solution for all eye wash stations.
Action required: 705 - Other - as specified
Due 20 October 2010
Resolved 20 September 2010
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Communications › Radio Communications › EPIRB
Issued 1 September 2010 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2011
Resolved 8 December 2011
Resolution: Verified placement of epirb as satisfactory and registration certificate cited.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 9 December 2009 Resolved
Provide proof of CG approval for SCBAs and air cylinders (DOT certfication). (Extended deficiency twice due to problems in shipping new cylinders). Received email that [name withheld] and DOT cylinders received onboard, extended def to next inspection.
Condition: Unknown
Due 29 January 2011
Resolved 19 September 2010
Resolution: Verified DOT certification.
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 9 December 2009 Resolved
Record annual tests identified in CG Approved Automation Test Procedures in accordance with the porcedures. Captain reports completed via email 1/28/2010 (Evan Massey, Captain USCG license [withheld]), left def open to next isnpection for verification.
Condition: Unknown
Due 29 January 2011
Resolved 19 September 2010
Resolution: Verified annual automation test were conducted.
Documentation › Logs/Records › Logbook (official)
Issued 9 December 2009 Resolved
Maintain USCG Official Log Book (provided). Left outstanding to verify at next annual.
Condition: Unknown
Due 29 January 2011
Resolved 19 September 2010
Resolution: USCG Official Log Book being used.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 9 December 2009 Resolved
Conduct required annual hydrostatic leak testing of fuel transfer hoses (150% MAWP). Received email report of completion (Evan Massey, Captain USCG license [withheld] ), left def open until next inspection for verification.
Condition: Improper/Lack of Maintenance
Due 29 January 2010
Resolved 19 September 2010
Resolution: Verified annual hydrostatics tests conducted.
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 9 December 2009 Resolved
Provide reord of annual thorough testing (MSC 1206) of rescue boat davit/winch by manufacturer's authorized representative, or approval from Ned-Deck to conduct such testing using other than service personnel from Original Equipment Manufacturer.Received email report of completion (Evan Massey, Captain USCG license [withheld] ), left def open until next inspection for verification.
Condition: Unknown
Due 29 January 2011
Resolved 19 September 2010
Resolution: Record provided for inspection.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 9 December 2009 Resolved
Provide buoyant leader heads appropriate for onboard line-throwing apparatus.
Condition: Improper Installation
Due 9 February 2010
Resolved 28 January 2010
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 9 December 2009 Resolved
Provide NOMEX flash gear for fire fighting ensembles onboard.Received email report of completion (Evan Massey, Captain USCG license [withheld] ), left def open until next inspection for verification.
Condition: Improper Installation
Due 29 January 2011
Resolved 19 September 2010
Resolution: NOMEX hood onboard.
Construction/Loadline › Markings › Load Line Mark
Issued 18 November 2008 Resolved
Permanently mark the load line and deck line on the side of the vessel.
Condition: Improper Installation
Due 18 December 2008
Resolved 8 December 2008
Engineering › Compressed Air System (control) › Valve
Issued 18 November 2008 Resolved
Prove proper operation of over pressure reliefs on pressure vessels.
Condition: Improper/Lack of Maintenance
Due 18 December 2008
Resolved 19 November 2008
Lifesaving › Inflatable Liferafts › Approval
Issued 18 November 2008 Resolved
Have vessels liferafts inspected at an approved facility.
Due 18 December 2008
Resolved 19 November 2008
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 18 November 2008 Resolved
Provide a serviced SCBA bottle.
Condition: Improper/Lack of Maintenance
Due 18 December 2008
Resolved 19 November 2008
Fire Fighting › International Shore Connection › Not on Board
Issued 18 November 2008 Resolved
Provide complete international shore connection for the vessel.
Due 18 December 2008
Resolved 9 December 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 November 2008 Resolved
Provide automatic door closures on generator and main engine space access doors.
Condition: Improper Installation
Due 18 January 2009
Resolved 9 December 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 November 2008 Resolved
Provide battery boxes for all spare batteries.
Condition: Improper Installation
Due 18 December 2008
Resolved 9 December 2008
Documentation › Manuals/Policy Documentation › Vessel Action Plan (SIP)
Issued 18 November 2008 Resolved
Provide approved automated test procedures for the vessel.
Condition: Improper/Lack of Maintenance
Due 18 December 2008
Resolved 9 December 2008
Documentation › Logs/Records › Oil Record Book
Issued 18 November 2008 Resolved
Provide up to date version of the uscg oil record book.
Condition: Improper Installation
Due 18 December 2008
Resolved 9 December 2008
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 18 November 2008 Resolved
Provide two buoyant floats for line throwing applicance as required.
Condition: Improper Installation
Due 18 December 2008
Resolved 9 December 2008
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 18 November 2008 Resolved
Prove proper operation of vessels emergency steering.
Condition: Improper Installation
Due 18 December 2008
Resolved 9 December 2008
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 18 November 2008 Resolved
Provide at each steering station suitable notice on wheel and or lever or in some other place directly in the helmsmans line of sight to indicate the direction in whichto turn the wheel orlever for right or left rudder.
Due 18 December 2008
Resolved 6 February 2009
Lifesaving › Inflatable Liferafts › Float Free
Issued 18 November 2008 Resolved
Provide shakles for liferaft hydrostatic release weak links.
Condition: Improper Installation
Due 18 December 2008
Resolved 9 December 2008
Fire Fighting › Nozzles › Condition
Issued 18 November 2008 Resolved
Provide connecting chains for all high velocity fog adaptors on navy all purpose nozzles.
Condition: Damaged By Earlier Event
Due 18 December 2008
Resolved 9 December 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 18 November 2008 Resolved
Prove proper operation of all FFF system time delays and engine shut downs.
Due 18 December 2008
Resolved 9 December 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 18 November 2008 Resolved
Provide approved fire plan at gangway.
Due 18 December 2008
Resolved 6 February 2009
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 18 November 2008 Resolved
Remove all rotted/molded produce from food stores. Provide fresh produce for crew consumption.
Due 18 December 2008
Resolved 9 December 2008
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 October 2007 Resolved
Provide a CG approved magnetic compass as required by SOLAS Ch. V reg. 18&19.
Action required: 705 - Other - as specified
Due 1 August 2008
Resolved 17 April 2008
Resolution: Cleared deficiency as per OCMI amendment letter.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 29 October 2007 Resolved
Provide a CG approved echo sounding device as required by SOLAS Ch. V reg. 18&19.
Action required: 705 - Other - as specified
Resolved 3 January 2008
Resolution: Installed Furuno FE-700 (165.107/2/0).
Navigation › Piloting/Steering › Gyro Compass
Issued 29 October 2007 Resolved
Provide a CG approved gyro compass as required by SOLAS Ch. V reg. 18&19.
Action required: 705 - Other - as specified
Resolved 20 February 2008
Resolution: Bureau of Veritas certificate provided through EU and USCG approval number issued under MRA.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 29 October 2007 Resolved
Provide a CG approved GPS as required by SOLAS Ch. V reg. 18&19.
Action required: 705 - Other - as specified
Resolved 14 February 2008
Resolution: Approved Furuno GP-150 installed.
Navigation › Collision/Grounding Avoidance › Radar
Issued 29 October 2007 Resolved
Provide a FCC approved radar as required by SOLAS Ch. V reg. 18&19.
Action required: 705 - Other - as specified
Resolved 14 February 2008
Resolution: Approved Furuno FR-1510 MK-3 installed.

Ownership record