Records from 2008 to 2025. Most recent: inspection, 21 July 2025.
Inspection history · 16
21 July 2025
Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8192539
9 July 2024
Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7985516
9 August 2023
Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7764330
8 June 2022
COI Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7465250
17 May 2022
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7454817
30 November 2021
Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7359189
30 August 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7302668
2 June 2020
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6966215
18 June 2019
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6704916
6 June 2018
DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6436153
19 April 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6394808
20 February 2018
Administrative Inspection · Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6358989
5 February 2018
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6358926
19 May 2017
Deficiency Check · Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6149930
30 November 2016
Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6049802
8 July 2016
Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5939162
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 July 2024
Resolved
Vessel Certificate of Documentation was not available at the time of inspection. Any vessel of at least 5 net tons who engages in coastwise trade must have a certificate of documentation. Vessel owner shall provide marine inspectors with a copy of the updated certificate of inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2024
Resolved 10 July 2024
Resolution: Vessel Owner provided local marine inspectors with a copy of the updated COD.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 June 2022
Resolved
CP1- Flares were found expired. Vessel owner/operator shall replace with the proper amount of flares for the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2022
Resolved 9 June 2022
Resolution: Vessel owner operator provided the vessel with new flares.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 June 2022
Resolved
Battery in the vessels strobe light was found expired. Vessel Owner/Operator shall replace with a battery of the approved type.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2022
Resolved 9 June 2022
Resolution: Owner/Operator supplied the vessel with a new battery for the strobe light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 June 2022
Resolved
08 adult sized life jackets were found deteriorated. MI witnessed the tearing of the life jackets to ensure they were not placed back in service. Vessel owner/operator shall replace the life jackets and ensure they are labelled IAW applicable cfr's.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2022
Resolved 9 June 2022
Resolution: Vessel Owner/Operator supplied the vessel with 08 new adult lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 June 2022
Resolved
Distress signal box was not labelled. Vessel owner/operator shall label the box "DISTRESS SIGNALS"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2022
Resolved 9 June 2022
Resolution: Vessel owner/operator labeled the stowage container accordingly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 June 2022
Resolved
Life Jacket stowed under the vessels seating area were not provided with a quantity at the location of stowage. Vessel owner/operator shall label life jacket stowage accordingly.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2022
Resolved 9 June 2022
Resolution: Vessel Owner/Operator labeled IAW with applicable CFR.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 August 2021
Resolved
The forward life-jacket box labeling was worn off and deteriorated. The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Vessel owner/operator should replace the labeling accordingly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2021
Resolved 15 September 2021
Resolution: storage bags were properly labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 August 2021
Resolved
During the inspection of the forward trampolines, it was identified the PVC piping surrounding the trampoline was cracked in several locations. At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Vessel owner/operator should replace the cracked PVC with the same or similar material.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2021
Resolved 15 September 2021
Resolution: trampoline PVC was repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 July 2019
Resolved
Provide storage for all life jackets accessible for passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2019
Resolved 1 July 2019
Resolution: Stowage corrected prior to MI's departure.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 1 July 2019
Resolved
Trampoline PVC tubing require repair to secure section with netting.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2019
Resolved 1 July 2019
Resolution: Item corrected prior to MI's departure.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2019
Resolved
Replace emergency lighting installation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2019
Resolved 1 July 2019
Resolution: Light replaced with sat results.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 June 2018
Resolved
Provide on board original COD
Action required: 10 - Deficiency Rectified
Due 9 July 2018
Resolved 24 July 2018
Resolution: Email provided with copy of COD provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2018
Resolved
Provide process and point of contact phone number how you intend to comply with passenger count regulations
Action required: 10 - Deficiency Rectified
Due 6 June 2018
Resolved 11 July 2018
Resolution: Plan with POC's received via email with special note inserted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2018
Resolved
Provide on board operable ring buoy light.
Action required: 10 - Deficiency Rectified
Due 9 July 2018
Resolved 24 July 2018
Resolution: Photo received showing required markings.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2018
Resolved
Provide copy of submitted MIS submitted to the U. S. Coast Guard my March 15th. (Submitted by consortium).
Action required: 10 - Deficiency Rectified
Due 6 July 2018
Resolved 11 July 2018
Resolution: Received email copy of document.
Stability › Watertight Integrity › Coaming
Issued 20 October 2017
Resolved
Permanent repair of hatch on foward starboard void will be made prior to 2018 operating season.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 9 July 2018
Resolution: Attended vessel finding all hatch combing repairs completed.
Stability › Watertight Integrity › Coaming
Issued 8 August 2017
Resolved
Provide a repair proposal for permanent repairs of the starboard side forward hatch. The proposed repairs need to be made prior to the 2018 operating season.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 20 October 2017
Resolution: A repair proposal was provided for forward starboard hatch. All painted wood on all the coaming and all painted wood on all the hatches will be replaced and coated with Epoxy west system.
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 May 2017
Resolved
Provide suitable strainer for both port and starboard raw water intakes.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 7 June 2017
Resolution: Vessel operator ordered and replaced parts to correct the leaking strainers.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 24 May 2017
Resolved
Re-stencil 29 adult life jacket container in net area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 7 June 2017
Resolution: The operator restenciled the life jacket container.
Electrical › Electric Supply System (service) › Cable
Issued 24 May 2017
Resolved
Correct sharp bends in electrical cable in port engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 7 June 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Stability › Watertight Integrity › General
Issued 24 May 2017
Resolved
Repair hole in bulkhead in forward part of starboard number 2 void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 7 June 2017
Resolution: Attended to the satisfaction of the attending marine inspector.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 24 May 2017
Resolved
Repair leaking hose on starboard side MSD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 7 June 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Stability › Watertight Integrity › General
Issued 24 May 2017
Resolved
Repair hatch on forward starboard void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 10 August 2017
Resolution: Temp repair made using additional batten and epoxy. Water hose spray test completed; no water intrusion observed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 September 2016
Resolved
Provide proper contents of First Aid kit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2016
Resolved 24 May 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 September 2016
Resolved
Provide FCC Safety Certificate.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2016
Resolved 24 May 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 7 September 2016
Resolved
Provide adequate, up to date navigation charts and publications.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2016
Resolved 24 May 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 September 2016
Resolved
Provide water light lanyard and life line for ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 14 September 2016
Resolution: New Water light lanyard and rescue installed.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 7 September 2016
Resolved
Provide portable lights at the operating stating and machinery spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2016
Resolved 24 May 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 September 2016
Resolved
Secure #4 starboard deck support rail with fastners.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2016
Resolved 24 May 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Electrical › Electric Supply System (service) › Cable
Issued 7 September 2016
Resolved
Secure bilge alarm wiring in all spaces.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2016
Resolved 24 May 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 September 2016
Resolved
Properly secure or remove dead end wiring in port bow space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2016
Resolved 24 May 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 7 September 2016
Resolved
Properly secure MSD and associated hoses.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2017
Resolved 24 May 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Engineering › Bilge Water Management System › Hose
Issued 7 September 2016
Resolved
Secure bilge pump discharge hose in port engine space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2016
Resolved 24 May 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 July 2016
Resolved
Replace expired waterlight batteries, make legible vessel name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 14 September 2016
Resolution: New waterlight battery and vessel placardining installed.