MAURY USCG vessel records Sign in
← All vessels

AUTSHUMATO

AUTSHUMATO is a 1998 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2007, most recently in November 2017, along with 48 deficiencies and 1 operational control.

Records from 2007 to 2017. Most recent: inspection, 28 November 2017.

Built
1998
Last inspected
28 November 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

ZJL7591
872616
Flag
VIRGIN ISLANDS, BRITISH
—
Maury page id
psix-872616

Inspections, by type

…with no type recorded1
Years with a record 6 calendar years (2007–2017)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it99 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

28 November 2017 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6435965
18 March 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6107222
28 September 2011 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4156159
16 November 2010 Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3892116
13 May 2009 MTSA/ISPS Verification · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3474139
28 April 2009 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3461955
12 November 2008 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3361364
13 May 2008 MTSA/ISPS Verification · COI Inspection · ISM Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3204973
29 April 2008 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3194759
3 May 2007 Initial Certification · MTSA/ISPS Verification · MARPOL Annex V Examination · ISM Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2922082
5 April 2007 Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2920542

Deficiency record · 48

Documentation › Certificates/Documents › FCC SSL
Issued 13 May 2009 Resolved
Provide a valid copy of the vsl’s Safety Radio Certificate
Action required: 705 - Other - as specified
Due 20 May 2009
Resolved 15 May 2009
Documentation › Logs/Records › Drug Test Records
Issued 13 May 2009 Resolved
Provide a current list of all crewmembers enrolled in Company’s Drug Testing Program.
Action required: 705 - Other - as specified
Due 20 May 2009
Resolved 15 May 2009
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 May 2009 Resolved
Renew cracked window port side sixth from forward and starboard side farthest aft in lower main accommodation space prior to next Dry-Dock.
Action required: 705 - Other - as specified
Due 28 April 2010
Resolved 27 April 2010
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 13 May 2009 Resolved
Renew cover for toilet pump where found missing.
Action required: 705 - Other - as specified
Due 20 May 2009
Resolved 11 August 2009
Electrical › Electric Generation Source (service) › Generator
Issued 13 May 2009 Resolved
Re-attach loose generator gauge console.
Action required: 705 - Other - as specified
Due 13 June 2009
Resolved 11 August 2009
Electrical › Electric Supply System (service) › Cable
Issued 13 May 2009 Resolved
Renew frayed cable/wiring in way of starboard main diesel engine.
Action required: 705 - Other - as specified
Due 20 May 2009
Resolved 11 August 2009
Construction/Loadline › Penetrations › Weld
Issued 13 May 2009 Resolved
Ensure watertight integrity of starboard steering compartment forward bulkhead.
Action required: 705 - Other - as specified
Due 20 May 2009
Resolved 11 August 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 May 2009 Resolved
Renew expired medication (i.e. eye flush, burn gel)
Action required: 705 - Other - as specified
Due 20 May 2009
Resolved 11 August 2009
Electrical › Electric Generation Source (emergency) › Generator Cable
Issued 13 May 2009 Resolved
Renew wiring for emergency light starboard aft deck with approved marine type.
Action required: 705 - Other - as specified
Due 13 June 2009
Resolved 11 August 2009
Engineering › Bilge Water Management System › Strainer
Issued 28 April 2009 Resolved
Remove all sediment in vicinity of port steering gear room bilge suction strainer.
Action required: 705 - Other - as specified
Due 28 April 2009
Resolved 28 April 2009
Stability › Unintentional Flooding › General
Issued 28 April 2009 Resolved
Make permanent repairs in way of port steering gear room flexible hose above exhaust, as shown.
Action required: 705 - Other - as specified
Due 28 April 2009
Resolved 28 April 2009
Lifesaving › Lifefloat › Markings
Issued 13 May 2008 Resolved
MARK ALL LIFEFLOATS WITH MAXIMUM CAPACITY. IN ADDITION, REMOVE ALL MARKINGS IN RELATION TO "AMERICAN PRIDE".
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 13 May 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 May 2008 Resolved
RENEW ANCHOR LIGHT BULB.
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 13 May 2008
Construction/Loadline › Structures › Scuttle
Issued 13 May 2008 Resolved
MAKE PERMANENT REPAIRS BY WELDING FRACTURE IN WAY OF DOG FOR FORWARD HATCH, AS MARKED.
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 13 May 2008
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 13 May 2008 Resolved
PERMANENTLY REMOVE GAUGE LINE FOUND IN WAY OF STARBOARD ENGINEROOM VENTILATION DAMPNER, AS SHOWN.
Action required: 705 - Other - as specified
Due 13 May 2008
Resolved 13 May 2008
Accommodation/Occupational Safety › Potable Water System › General
Issued 13 May 2008 Resolved
MAKE PERMANENT REPAIRS TO FRESH WATER PUMP LEAK IN PORT FORWARD COMPARTMENT, AS SHOWN.
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 13 May 2008
Construction/Loadline › Penetrations › Pipe Flange
Issued 29 April 2008 Resolved
MAKE PERMANENT REPAIRS TO SOFT-PATCHED PIPE FOR TOILET OVERBOARD LOCATED IN STARBOARD AFT ENGINEROOM BULKHEAD.
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 12 November 2008
Electrical › Electrical Distribution System (service) › Panelboard
Issued 29 April 2008 Resolved
MAKE PERMANENT REPAIRS TO ELECTRICAL PANEL BOX LOCATED ON STARBOARD ENGINE ROOM AFT BULKHEAD.
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 13 May 2008
Construction/Loadline › Structures › Deck Plating
Issued 29 April 2008 Resolved
SEAL ALL OPENINGS FOUND IN PORT AND STARBOARD FORWARD VOID INCLUDING PORT AND STARBOARD BOW IN WAY OF SHELL LONGITUDINAL, AS MARKED. (TOTAL OF NINE (9) PORT SIDE AND TEN (10) ON STARBOARD SIDE).
Action required: 705 - Other - as specified
Due 13 May 2008
Resolved 13 May 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 29 April 2008 Resolved
SEAL ALL PENETRATIONS FOUND IN FORWARD OUTBOARD BULKHEAD IN STARBOARD AFT VOID.
Action required: 705 - Other - as specified
Due 13 May 2008
Resolved 13 May 2008
Lifesaving › Lifefloat › Painter
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, HARDSPLICE ALL LIFEFLOAT PAINTER AND FLOATING LIGHT LINES.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 3 May 2007
Fire Fighting › Firemans Outfit › Axe
Issued 3 May 2007 Resolved
MARK FIRE AXE WITH VESSELS NAME.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 May 2007
Resolved 14 May 2007
Fire Fighting › Ventilation Systems › Ducts
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, PROVIDE AND INSTALL GASKET MATERIAL FOR ALL VENTILATION EMERGENCY CLOSURE DEVICES.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 14 May 2007
Construction/Loadline › Hull › Side Shell
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, WELD SIDE SHELL WELD SEAM IN VOID #3, AS SHOWN.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 14 May 2007
Construction/Loadline › Structures › Door
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, REMOVE ALL UNSERVICABLE WT BULKHEAD HATCH DOORS THAT WHERE MODIFIED FOR STABILITY PURPOSES.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 14 May 2007
Engineering › Bilge Water Management System › Not Operational
Issued 3 May 2007 Resolved
REMOVE ALL MARKINGS IN RELATION TO PORT AND STARBOARD FOREPEAK DRAIN VALVE REMOTE CONTROL IN LOWER PASENGER SALON.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 3 May 2007
Resolved 3 May 2007
Construction/Loadline › Structures › Machinery Space Opening
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, LABEL ESCAPE SCUTTLE IN CONCESSION AREA AS, "EMERGENCY ESCAPE - DO NOT OBSTRUCT".
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 14 May 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, INSTALL COVER FOR PUMP PRESSURE SWITCH LOCATED IN PORT FUEL OIL STORAGE TANK COMPARTMENT.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 14 May 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, INSTALL MOUNTING HARDWARE FOR DECK PLATES LOCATED IN PORT FUEL OIL STORAGE TANK COMPARTMENT.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 14 May 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, INSTALL LENSE COVER FOR EACH OVERHEAD LIGHT FIXTURE AT STBD ENGINE ROOM ENTRANCE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 14 May 2007
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, REMOVE DEAD-ENDED ELECTRICAL WIRING FOUND AT STBD ENGINE ROOM ENTRANCE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 3 May 2007
Electrical › Lighting (emergency) › Lighting Feeder
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, MARK ALL EMERGENCY LIGHT FIXTURES WITH A RED "E".
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 3 May 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, INSTALL GUARD FOR STARBOARD GENERATOR FAN.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 14 May 2007
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, RE-INSTALL ELECTRICAL GROUND CABLE TO STARBOARD MAIN ENGINE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 3 May 2007
Stability › Unintentional Flooding › General
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, INSTALL CAP FOR VALVE LOCATED ON FORWARD, OUTBOARD HULL IN STARBOARD ENGINE ROOM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 14 May 2007
Stability › Watertight Integrity › General
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, MAKE PERMANENT REPAIRS TO HOLED WATERTIGHT BULKHEAD AT PENETRATIONS BELOW DECK PLATES BETWEEN PORT ENGINE ROOM AND PORT STEERING ROOM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 14 May 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, INSTALL MOUNTING HARDWARE FOR PORT ENGINE ROOM DECK PLATES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 14 May 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, MARK THE UPPER DECK PASSENGER CAPACITY AT A MAXIMUM OF FIFTY-FIVE (55) AS PER VESSELS STABILITY LETTER.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 14 May 2007
Documentation › Markings/Placards › Oil Discharge Placard
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, PROVIDE AND INSTALL A "DISCHARGE OF OIL PROHIBITED" PLACARD/DECAL IN VICINITY OF PORT AND STARBOARD BILGE OVERBOARD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 3 May 2007
Documentation › Markings/Placards › Garbage Placard
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, PROVIDE AND INSTALL MARPOL GARBAGE DUMPING RESTRICTIONS PLACARD/DECAL IN WHEELHOUSE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 3 May 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, INSTALL PERSONNEL LADDER FOR PORT AND STARBOARD ENGINE ROOM DECK ENTRANCE/EMERGENCY ESCAPE.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 14 May 2007
Engineering › Bilge Water Management System › Not Operational
Issued 3 May 2007 Resolved
PRIOR TO CARRYING MORE THAN SIX (6) PASSENGERS FOR HIRE IN U.S. WATERS, PROVE PROPER OPERATION OF BILGE SYSTEM WHEN CROSS-CONNECTED.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 14 May 2007
Lifesaving › Hand Flares › Storage
Issued 3 May 2007 Resolved
PROVIDE BRIGHTLY COLORED LABELED WATERTIGHT BOX FOR HAND HELD FLARES
Due 3 May 2007
Resolved 15 May 2007
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 3 May 2007 Resolved
PROVIDE 2 ADDITIONAL CHILD PFD'S
Due 3 May 2007
Resolved 15 May 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 May 2007 Resolved
REOVE OR BOLT DOWN BEVERAGE COOLER IN GALLEY AREA
Due 3 May 2007
Resolved 15 May 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 3 May 2007 Resolved
PROVIDE AUTOMATIC SHUTDOWNS FOR PROPULSION ENGINES, GENERATOR, AND VENTILATION BLOWERS UPON CO2 ACTIVATION
Due 3 May 2007
Resolved 15 May 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 3 May 2007 Resolved
PROVIDE PROPER MAN OVERBOARD RECOVERY LADDER
Due 3 May 2007
Resolved 15 May 2007
Fire Fighting › Fire Pumps › Pressure
Issued 3 May 2007 Resolved
PROVIDE A FIRE PUMP WITH A CAPACITY OF 50 GPM AT 60 PSI. EXISTING PORT AND STBD FIRE PUMPS MAY BE USED AS A SUBSTITUTE UNTIL DUE DATE OF THIS REQUIREMENT. BOTH FIRE PUMPS MUST REMAIN OPERATIONAL AT ALL TIMES. THE VESSEL IS TO BE REMOVED FROM SERVICE IF EITHER PUMP BECOMES INOPERATIVE.
Due 26 June 2007
Resolved 25 June 2007

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.