NUMBER THREE

Built
2007
Last inspected
26 February 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 26 February 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 19 calendar years (2007–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

872637
Flag
UNITED STATES
Maury page id
psix-872637

Documentation record

Registered dimensions (L × B × D)296.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,748 / net 1,748
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBOLLINGER MARINE FABRICATORS LLC · AMELIA, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un
DocumentationValid · issued 2 July 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1748 - Simplified, Gross Ton
1748 - Simplified, Net Ton
4500 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 30 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

JOKER Towing Vessel · MISLE 167218 · 9 March 2016 · activity 5858337

Inspection history · 30

26 February 2026 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8312834
19 February 2025 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8082044
12 February 2025 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 8129675
13 March 2024 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7877895
15 March 2023 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7650877
17 March 2022 Periodic Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7413405
26 January 2022 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7387720
31 March 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7166129
26 March 2021 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7163244
12 March 2020 MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6925253
19 December 2019 Cargo Tank Internal · Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6876547
28 August 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6254153
20 July 2016 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5946299
9 March 2016 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5858337
11 September 2015 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5719456
17 August 2015 Load Line/Change of Employment · Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5219130
11 February 2015 Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5067546
30 September 2014 Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4995942
4 December 2013 Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4763804
10 June 2013 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4718874
23 July 2012 COI Inspection · Drydock Exam · Administrative Inspection · MTSA Verification · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4387939
5 June 2012 Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4334618
21 June 2011 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4052434
14 June 2011 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4044486
1 June 2010 MTSA Verification · Periodic Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3754967
22 June 2009 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3505469
8 April 2009 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3448485
8 May 2008 MARPOL Annex I Examination · MARPOL Annex V Examination · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3204491
23 July 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3007662
7 May 2007 Initial Certification · MARPOL Annex II Examination · Hull Examination · Construction Oversight · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2924092

Deficiency record · 17

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 February 2025 Resolved
All installations must be of marine type engines suitable for the intended service...During inspection of the port side cargo pump, observed visible exhaust leak and burnt lagging on the exhaust piping near the turbocharger. 46 CFR 32.35-1 46 CFR 58.10-5(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2025
Resolved 2 April 2025
Resolution: Received tech report. See docs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 March 2023 Resolved
The frame or support of each size III,IV,and V fire extinguisher required by table 34.50-10(a) must be welded or otherwise permanently attached to a bulkhead or deck. Vessel did not have its cargo tank area semi-portable fire extinguisher permanently attached to a bulkhead or deck.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2023
Resolved 16 March 2023
Resolution: Semiportable fire extinguisher affixed to deck correctly
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 15 March 2023 Resolved
The high-level alarm required by paragraph (a) of this section must - (2) Be identified with the legend “High-level Alarm” in black letters at least 50.8 millimeters (2 inches) high on a white background. The tank overfill alarm required by paragraph (a) of this section must - (2) Be identified with the legend “TANK OVERFILL ALARM” in black letters at least 50.8 millimeters (2 inches) high on a white background. Vessel did not have adequate labeling of the high level and overfill alarms.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2023
Resolved 16 March 2023
Resolution: High Level, Overfill signage posted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 17 March 2022 Resolved
If the periodic inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the OCMI. Observed missing gasket in the starboard forepeak hatch. 46 CFR 31.10 17(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 21 March 2022
Resolution: Vessel replaced gasket in forepeak hatch cover.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 17 March 2022 Resolved
A pressure gage shall be installed for each pump discharge, and it shall be located at a point visible with respect to the pump controls. Observed malfunctioning pressure gauge on the port cargo pump. Replace prior to use of port cargo pump. 46 CFR 32.50 5(a)
Action required: 705 - Other - as specified
Resolved 21 March 2022
Resolution: Vessel installed new pressure gauge.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 March 2022 Resolved
Each cargo tank of a tank barge must have one of the following liquid overfill protection arrangements. Observed inoperable loss of power alarm due to dead batteries. Replace prior to loading cargo operations. 46 CFR 39.2009(a)
Action required: 705 - Other - as specified
Resolved 21 March 2022
Resolution: Vessel replaced batteries. Witnessed satisfactory alarm.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 March 2022 Resolved
Each cable installation must meet - sections 25, except 25.11, of IEEE 45-200. Observed multiple broken/missing band clamps for wire cables under the port and stbd house. Install clamps every two feet or every frame, whichever is less. 46 CFR 111.60 5(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 21 March 2022
Resolution: Vessel replaced missing clamps.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 26 March 2021 Resolved
Pumprooms on tank vessels carrying Grade A, B, C, D and/or E liquid cargo - TB/ALL. (a) Cargo pumps. In tank vessels carrying Grade A, B, C, or D liquid cargo, cargo pumps shall be isolated from source of vapor ignition by gastight bulkheads. A gastight bulkhead between the pumproom and the pump engine room may be pierced for drive shaft and pump engine control rods provided such openings are fitted with stuffing boxes or other approved gland arrangement. Both port and starboard cargo pump room shaft vapor seals were deteriorated, worn, or torn to the point that vapor tightness was unable to be maintained. Vessel shall not conduct cargo operations until suitable replacement are in place and vapor tightness is resumed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2021
Resolved 30 March 2021
Resolution: Corrected. No further action required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2021 Resolved
Gears, couplings, flywheels and all machinery capable of injuring personnel shall be provided with adequate cover or guards. Generator had no protective cover for the flywheel belt.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2021
Resolved 14 April 2021
Resolution: Resolved. No further action required.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 26 March 2021 Resolved
Subpart B-Required Chemical Testing Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49CFR Part 40. Vessel representative could not produce and records of required chemical testing, tracking, or sampling.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 30 March 2021
Resolution: Corrected. No further Action required.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 18 March 2020 Resolved
Nonmetalic flexible hose may be used in lube oil, fuel oil, and fluid power systems only where flexability is required and in lengths not exceeding 30 inches. 46 CFR 56.60-25(b)4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2020
Resolved 30 March 2021
Resolution: Resolved. No Further Action Required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 March 2020 Resolved
Each vessel must carry lifejackets for each person onboard. Each lifejacket must be marked with type 1 retro-reflective materials. Both lifejackets are not type 1 and have no retro. Replace to the satisfaction of the attending CG inspector. 46 CFR 199.70(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2020
Resolved 30 March 2021
Resolution: Resolved. No Further Action Required.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 18 March 2020 Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward, loacated at the top of the flange. Both manifold vapor flanges did not have a stud intalled. 46 CFR 39.2001(j)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2020
Resolved 30 March 2021
Resolution: Resolved. No Further Action Required.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 March 2020 Resolved
The frame or support of each size III, IV, and V fire extinguisher required by table 34.50-10(a) must be welded or otherwise permanently attached to a bulkhead or deck. Semi-portable extinguisher was not secured to the vessel. 46 CFR 199.290(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2020
Resolved 30 March 2021
Resolution: Resolved. No Further Action Required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 March 2020 Resolved
Each lifesaving appliance must be in working order. Both life rings were found with deteriorated grab lines. 46 CFR 199.190(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2020
Resolved 30 March 2021
Resolution: Resolved. No Further Action Required.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 December 2019 Resolved
Identified areas of hull plating to be cropped and renewed; 1 on port side sheer strake amidships, 1 on starboard quarter at the turn of the notch. See 835 for details.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2020
Resolved 13 January 2020
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 11 September 2015 Resolved
Pressure guage shall be installed for each pump discharge, and it shall be located at a point visible with respect to the pump controls. Gauge is not visible from operating system.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 August 2017
Resolved 15 September 2015
Resolution: Vaportight porthole windows were installed with fixed glass view to view the pressure guages.

Recorded names · 1

DBL 22 (2007–2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.