Records from 2016 to 2025. Most recent: inspection, 14 July 2025.
Documentation record
Registered dimensions (L × B × D)40.7 ft × 18.0 ft × 4.5 ft
Registered tonnagegross 34 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOAT CO · CAERNARVON LA, UNITED STATES · built 1965
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW IBERIA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 30 April 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
14 July 2025
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8185725
21 August 2024
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7986239
22 March 2023
Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7658440
15 March 2022
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7412355
15 March 2022
Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7412390
1 February 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7136247
11 May 2020
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6949915
26 February 2020
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6916207
16 January 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6611396
8 March 2018
Internal Structural Exam · Hull Examination · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6368555
3 March 2017
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6098474
28 January 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5805472
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 March 2022
Resolved
A whistle fitted in a vessel less than 20 meters in length shall provide an audible range of not less than 0.5 nautical miles. Vessel's installed sound producing device was inoperable. 33 CFR 86.01(c).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2022
Resolution: A portable sound producing device was placed onboard to meet the 0.5 NM audible requirement.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 1 February 2021
Resolved
The master shall conduct sufficient drills and give sufficient instruction to make sure that all crewmembers are familiar with their duties during emergencies that necessitate abandon ship or the recovery of persons who have fallen overboard. Abandon ship drills and training shall be logged or otherwise documented. The drill entry shall include the date of the drill and training and the general description of the drill scenario and training topics. The vessels master could not provide logs or evidence of man overboard or abandon ship drills or training. Additionally, the vessels crew was unfamiliar with their duties during man overboard drill and did not receive training onboard the vessel. Vessel shall conduct man overboard drills and training prior to getting underway to the satisfaction of the Coast Guard. 46 CFR 185.520(a) & (f)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2021
Resolution: Crew completed satisfactory man overboard drill in presence of CG marine inspectors.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 1 February 2021
Resolved
The owner or master shall instruct each crewmember, upon first being employed for the first time on a particular vessel and at least once every three months as to the duties the crewmember is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard. Crew training shall be logged or otherwise documented. The training entry shall include the date of the training and the general description of the training topics. The vessels owner or master could not provide logs or evidence of training. Vessel shall conduct training prior to getting underway to the satisfaction of the Coast Guard. 46 CFR 185.420(a) & (c)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2021
Resolution: Received satisfactory evidence of crew training completed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 February 2021
Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the end of the fuel line to stop fuel flow when servicing accessories. During inspection it was discovered that the forward fuel tank emergency remote fuel shutoff valve was located at a secondary valve down line from the fuel tank, approximately 2' from the valve installed at the fuel tank. At next drydock exam vessel shall alter placement of forward emergency fuel shut off valve to be located at the closest valve to the fuel tank. 46 CFR 182.20-40(b)(3)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 8 February 2021
Resolution: Shut off valve was installed in the appropriate location.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 1 February 2021
Resolved
Each ring life buoy on a vessel must be stowed in a way that it can be rapidly cast loose. During the man over board drill, it was discovered that the attached life line was tied up in a way which prevented it from being rapidly cast loose. The deckhand made two unsuccessful attempts to deploy the ring buoy prior to securing the drill. Vessel shall ensure all lifelines onboard the vessel are stowed in a way which allows rapid cast prior to departure. 46 CFR 180.70(b)(3)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2021
Resolution: Owner/operator replaced all lifelines on vessel with bag type lifeline.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 January 2019
Resolved
Engine room escape hatch must e provided adequate emergency lighting per 46 CFR 184.30-5(a).
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2019
Resolved 24 January 2019
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 January 2019
Resolved
Engine room escape hatch must e provided adequate emergency lighting per 46 CFR 184.30-5(a).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2019
Resolved 24 January 2019
Resolution: Corrected.
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 January 2016
Resolved
Battery is missing a vent cap which needs to be replaced. Batter has excessive corrosion on one terminal which needs to be cleaned. Battery container has some standing oily water in it which needs to be removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 1 February 2016
Resolution: Cleaned
Engineering › Fuel Oil Service System › Hose
Issued 28 January 2016
Resolved
MDE fuel return line has a small section that is chafed beyond the outer cover and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 1 February 2016
Resolution: Replaced