Registered dimensions (L × B × D)36.0 ft × 13.0 ft × 4.3 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCARMAN BOATS INC · MARION, MD, UNITED STATES · built 2007
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSEWARD, AK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
28 May 2026
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8434187
4 June 2025
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8162185
7 May 2025
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8130354
29 April 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7903587
2 May 2023
Annual Inspection · Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam · Hull Examination
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7679469
4 August 2022
Type not recorded
No type recorded · USCGC LIBERTY (WPB 1334) · USCG Arctic District (CGD-A) · Activity 7524758
23 May 2022
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7457593
25 April 2022
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7438829
26 August 2021
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7295846
27 April 2021
Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7185204
23 June 2020
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6986140
2 May 2019
Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6675578
22 April 2019
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6667919
7 May 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6404329
26 June 2017
Type not recorded
No type recorded · USCGC CHANDELEUR (WPB 1319) · USCG Arctic District (CGD-A) · Activity 6189096
1 June 2017
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6243051
17 May 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6137560
24 April 2017
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6123860
14 November 2016
Plan Review "T" Boat · Administrative Inspection · Construction Oversight
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6167551
2 May 2016
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5824430
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 4 June 2025
Resolved
03105 - A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Hatch covers on the outside of the cabin did not have a hinge, captive chains, or other device to prevent loss of hatch. 46 CFR 179.360
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2025
Resolved 4 June 2025
Resolution: Vessel submitted photographic evidence showing chains added to prevent loss to all external hatches.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 June 2025
Resolved
11116 - Each flare carried to meet this section must be stowed in one of the following: (1) A portable watertight container marked as required by § 185.614 of this chapter, carried at the operating station; or (2) A pyrotechnic locker secured above the freeboard deck, away from heat, in the vicinity of the operating station. Vessel's pyrotechnic storage was stored in a neoprene bag that was not watertight. 46 CFR 180.68(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2025
Resolved 4 June 2025
Resolution: Vessel replaced existing container with a watertight container.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 June 2023
Resolved
All radiotelephones must contain the MMSI and integral GPS capabilities or must be connected to an electronic position-fixing device. All VHF radios must have the MMSI programmed and linked to GPS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2023
Resolved 5 July 2023
Resolution: Completed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 2 May 2023
Resolved
A pre-engineered fixed gas fire extinguishing system must be installed and maintained in accordance with the manufacturer's instructions. The system did not pass the annual certification and will require a replacement cylinder. The vessel is authorized to operate with the following additional safety measures:
1. 1-hr rounds of the machinery space while operating
2. Official log entires must be made to show completion
3. Two additional 40-B:C portable extinguishers must be on board and readily available.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 12 June 2023
Resolution: A new cylinder was installed and tested.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 2 May 2023
Resolved
The vessel must have an indication of a high water level in all spaces subject to flooding. The Laz switch does not work.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2023
Resolved 21 June 2023
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 May 2022
Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the OCMI. 01 fire extinguishers not in approved breacket. Mount fire extinguisher to the satisfaction of the Marine Inspector.
46CFR181.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2022
Resolved 31 May 2022
Resolution: Fire extinguisher mounted to satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 April 2022
Resolved
Life raft failed testing and removed from service
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2022
Resolved 23 May 2022
Resolution: Replace liferaft
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 June 2020
Resolved
EPIRB hydrostatic release was found expired, renew. Vessel is restricted to 03 NM from land or make EPIRB float free.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 15 July 2020
Resolution: Renewed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 June 2020
Resolved
Renew FCC Safety Certificate
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 15 July 2020
Resolution: Renewed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 June 2020
Resolved
Display donning instructions for all types of PFDs on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 15 July 2020
Resolution: Provided
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 8 May 2019
Resolved
Ensure EPIRB registration matches UIN of EPIRB.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 16 May 2019
Resolution: Verified EPIRB registration
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 May 2019
Resolved
Label emergency fuel shutoffs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 16 May 2019
Resolution: Fuel shutoff location was labeled.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 May 2018
Resolved
Has expired eye wash and burn gel, needs to replace
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 10 May 2018
Resolution: Vessel replaced burn gel and eye wash for first aid kit.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 May 2018
Resolved
Missing light list & tide tables
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 10 May 2018
Resolution: Vessel received current Coast Pilot and Light List on board.
Communications › Radio Communications › EPIRB
Issued 7 May 2018
Resolved
battery on EPRIB was expired, needs replaced, can sail w/i 3 nm until battery is repalced
Action required: 17 - Rectify deficiencies prior to departure
Due 21 May 2018
Resolved 10 May 2018
Resolution: Vessel purchased new EPIRB with valid battery.
Stability › Watertight Integrity › General
Issued 17 May 2017
Resolved
Provide retention cables for weather deck hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 31 May 2017
Resolution: Cables installed.
Fire Fighting › Fire Bucket › Availability
Issued 17 May 2017
Resolved
Provide a 3rd 2.5 gallon fire bucket with lanyard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 31 May 2017
Resolution: fire buckets provided
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 17 May 2017
Resolved
Provide current charts for area of operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 31 May 2017
Resolution: Charts onboard.
Stability › Watertight Integrity › Coaming
Issued 17 May 2017
Resolved
Provide 6 inch coaming for cabin access door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 31 May 2017
Resolution: coaming installed