MAURY USCG vessel records Sign in
← All vessels

ONE DAY

ONE DAY is a 2007 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2006, most recently in May 2026, along with 36 deficiencies.

Records from 2006 to 2026. Most recent: inspection, 28 May 2026.

Built
2007
Last inspected
28 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH4967
872918
Flag
UNITED STATES
367623160
Maury page id
psix-872918

Inspections, by type

…with no type recorded2
Years with a record 17 calendar years (2006–2026)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)36.0 ft × 13.0 ft × 4.3 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCARMAN BOATS INC · MARION, MD, UNITED STATES · built 2007
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSEWARD, AK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH4967MMSI 367623160 · active · compulsorily equipped · granted 29 May 2024, expires 23 May 2034
WDD7432MMSI 367186330 · cancelled · compulsorily equipped · granted 10 May 2007, cancelled 24 February 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 27

28 May 2026 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8434187
4 June 2025 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8162185
7 May 2025 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8130354
29 April 2024 Administrative Inspection · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7903587
2 May 2023 Annual Inspection · Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam · Hull Examination
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7679469
4 August 2022 Type not recorded
No type recorded · USCGC LIBERTY (WPB 1334) · USCG Arctic District (CGD-A) · Activity 7524758
23 May 2022 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7457593
25 April 2022 Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7438829
26 August 2021 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7295846
27 April 2021 Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7185204
23 June 2020 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6986140
2 May 2019 Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6675578
22 April 2019 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6667919
7 May 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6404329
26 June 2017 Type not recorded
No type recorded · USCGC CHANDELEUR (WPB 1319) · USCG Arctic District (CGD-A) · Activity 6189096
1 June 2017 Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6243051
17 May 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6137560
24 April 2017 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6123860
14 November 2016 Plan Review "T" Boat · Administrative Inspection · Construction Oversight
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6167551
2 May 2016 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5824430
28 May 2014 In-Service Inspection · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4872818
22 May 2012 COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4315615
22 April 2009 Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3458247
2 April 2009 Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3445129
7 May 2008 MARPOL Annex V Examination · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3246405
23 May 2007 MARPOL Annex V Examination · Deficiency Check · Initial Certification · Simplified Stability Test · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2939398
13 June 2006 Hull Examination · Construction Oversight · Simplified Stability Test · Plan Review "T" Boat
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2905224

Deficiency record · 36

03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 4 June 2025 Resolved
03105 - A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Hatch covers on the outside of the cabin did not have a hinge, captive chains, or other device to prevent loss of hatch. 46 CFR 179.360
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2025
Resolved 4 June 2025
Resolution: Vessel submitted photographic evidence showing chains added to prevent loss to all external hatches.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 June 2025 Resolved
11116 - Each flare carried to meet this section must be stowed in one of the following: (1) A portable watertight container marked as required by § 185.614 of this chapter, carried at the operating station; or (2) A pyrotechnic locker secured above the freeboard deck, away from heat, in the vicinity of the operating station. Vessel's pyrotechnic storage was stored in a neoprene bag that was not watertight. 46 CFR 180.68(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2025
Resolved 4 June 2025
Resolution: Vessel replaced existing container with a watertight container.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 June 2023 Resolved
All radiotelephones must contain the MMSI and integral GPS capabilities or must be connected to an electronic position-fixing device. All VHF radios must have the MMSI programmed and linked to GPS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2023
Resolved 5 July 2023
Resolution: Completed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 2 May 2023 Resolved
A pre-engineered fixed gas fire extinguishing system must be installed and maintained in accordance with the manufacturer's instructions. The system did not pass the annual certification and will require a replacement cylinder. The vessel is authorized to operate with the following additional safety measures: 1. 1-hr rounds of the machinery space while operating 2. Official log entires must be made to show completion 3. Two additional 40-B:C portable extinguishers must be on board and readily available.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 12 June 2023
Resolution: A new cylinder was installed and tested.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 2 May 2023 Resolved
The vessel must have an indication of a high water level in all spaces subject to flooding. The Laz switch does not work.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2023
Resolved 21 June 2023
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 May 2022 Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the OCMI. 01 fire extinguishers not in approved breacket. Mount fire extinguisher to the satisfaction of the Marine Inspector. 46CFR181.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2022
Resolved 31 May 2022
Resolution: Fire extinguisher mounted to satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 April 2022 Resolved
Life raft failed testing and removed from service
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2022
Resolved 23 May 2022
Resolution: Replace liferaft
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 June 2020 Resolved
EPIRB hydrostatic release was found expired, renew. Vessel is restricted to 03 NM from land or make EPIRB float free.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 15 July 2020
Resolution: Renewed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 June 2020 Resolved
Renew FCC Safety Certificate
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 15 July 2020
Resolution: Renewed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 June 2020 Resolved
Display donning instructions for all types of PFDs on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 15 July 2020
Resolution: Provided
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 8 May 2019 Resolved
Ensure EPIRB registration matches UIN of EPIRB.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 16 May 2019
Resolution: Verified EPIRB registration
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 May 2019 Resolved
Label emergency fuel shutoffs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 16 May 2019
Resolution: Fuel shutoff location was labeled.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 May 2018 Resolved
Has expired eye wash and burn gel, needs to replace
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 10 May 2018
Resolution: Vessel replaced burn gel and eye wash for first aid kit.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 May 2018 Resolved
Missing light list & tide tables
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 10 May 2018
Resolution: Vessel received current Coast Pilot and Light List on board.
Communications › Radio Communications › EPIRB
Issued 7 May 2018 Resolved
battery on EPRIB was expired, needs replaced, can sail w/i 3 nm until battery is repalced
Action required: 17 - Rectify deficiencies prior to departure
Due 21 May 2018
Resolved 10 May 2018
Resolution: Vessel purchased new EPIRB with valid battery.
Stability › Watertight Integrity › General
Issued 17 May 2017 Resolved
Provide retention cables for weather deck hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 31 May 2017
Resolution: Cables installed.
Fire Fighting › Fire Bucket › Availability
Issued 17 May 2017 Resolved
Provide a 3rd 2.5 gallon fire bucket with lanyard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 31 May 2017
Resolution: fire buckets provided
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 17 May 2017 Resolved
Provide current charts for area of operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 31 May 2017
Resolution: Charts onboard.
Stability › Watertight Integrity › Coaming
Issued 17 May 2017 Resolved
Provide 6 inch coaming for cabin access door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 31 May 2017
Resolution: coaming installed
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 May 2012 Resolved
Double clamp sea suctin hose on starboard engine after strainer.
Due 5 June 2012
Resolved 20 June 2012
Resolution: Double clamped.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 22 May 2012 Resolved
Provide capability of manual actuation for fixed extinguishing system.
Due 5 June 2012
Resolved 20 June 2012
Resolution: Manual capability provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 22 May 2012 Resolved
Install fire extinguisher aft of house in manufacturer's bracket.
Due 5 June 2012
Resolved 20 June 2012
Resolution: Bracket provided is more substantial than that provided by the manufacturer.
Navigation › Piloting/Steering › US Coast Pilot
Issued 22 May 2012 Resolved
Provide current copy of Light List and Coast Pilot.
Due 5 June 2012
Resolved 20 June 2012
Resolution: Provided.
Stability › Unintentional Flooding › General
Issued 7 April 2009 Resolved
Make permanent repairs to drilled holes (1ea) Lazerette and (2ea) engine room IAW NVIC 8-87ch1 or install approved dry-dock plug.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 7 April 2009 Resolved
Properly provide proof of annual service of firefighting extinguishers IAW 46 CFR 176.810.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2009
Stability › Watertight Integrity › General
Issued 7 April 2009 Resolved
Make engine room/lazerette bulkhead water tight and provide metallic bulkhead penetrations for F/O line from tank to engines IAW 46 CFR 182.720(d)(1).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2009
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 7 May 2008 Resolved
Provide proof of entry in drug & alcohol program
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2008
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 7 May 2008 Resolved
Provide one additional adult lifejacket with light
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 6 June 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 7 May 2008 Resolved
Mount B-II portable fire extinguisher at operating station
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 6 June 2008
Lifesaving › Lifebuoys › Serviceable
Issued 7 May 2008 Resolved
Add retro reflective tape to life ring
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 6 June 2008
Communications › Audible Communications › Horn/Whistle
Issued 7 May 2008 Resolved
Prove operation of horn
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 6 June 2008
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 12 June 2007 Resolved
Seperate childs from adult life jackets.
Due 12 July 2007
Resolved 22 July 2007
Resolution: Cleared via telephone.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 12 June 2007 Resolved
Mark "Emergency Escape" (Both sides).
Due 12 July 2007
Resolved 22 July 2007
Resolution: Cleared via telephone.
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 June 2007 Resolved
Make raw water and fuel lines not more than 30".
Due 12 July 2007
Resolved 29 February 2008
Resolution: Recieved digital photos of installed approved hoses.
Operations/Management › Passenger Operations › Safety Orientation
Issued 12 June 2007 Resolved
Post emergency instructions.
Due 12 July 2007
Resolved 22 June 2007
Resolution: Cleared via telephone.
Accommodation/Occupational Safety › Ventilation › General
Issued 12 May 2007 Resolved
Mark air closures for engine room "OPEN" "CLOSE"
Due 12 June 2007
Resolved 22 July 2007
Resolution: Cleared via telephone.

Ownership record