Records from 2008 to 2025. Most recent: inspection, 7 October 2025.
Documentation record
Registered dimensions (L × B × D)61.8 ft × 18.5 ft × 9.1 ft
Registered tonnagegross 69 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDUCKWORTH STEEL BOATS · TARPON SPRINGS, FL, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portS PADRE ISLAND, TX
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 7 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it69 - Simplified, Gross Ton
55 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
7 October 2025
Drydock Exam · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8247303
30 April 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8116923
30 May 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7922757
14 September 2023
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7778690
28 March 2023
COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7655588
12 April 2022
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7431682
27 September 2021
Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7322919
20 May 2021
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7202142
1 April 2020
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6935995
24 September 2019
Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6826286
3 May 2019
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6676087
3 April 2018
COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6378691
27 September 2017
Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6276255
27 June 2017
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6188604
29 June 2016
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5932492
30 September 2015
Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5749409
29 September 2011
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4158092
22 February 2011
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3950212
21 September 2010
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3854089
6 July 2008
Administrative Inspection · Deficiency Check · Initial Certification · Simplified Stability Test
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3255991
1 April 2008
Construction Oversight · Plan Review "T" Boat · Simplified Stability Test
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3175213
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 30 April 2025
Resolved
At each inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems. The crew-member conducting the man over board (MOB) drill was unable to retrieve the MOB due to the Jacobs ladder. Present to the MI within two weeks a plan for a rescue platform.
46 CFR 176.808 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2025
Resolution: MI received plans for a new rescue platform.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2024
Resolved
All unfired pressure vessels must be installed to the satisfaction of the cognizant [name withheld] vessels must meet the applicable requirements of subchapter F of this chapter. Pressure vessels shall be designed, constructed, and inspected in accordance with section VIII of the ASME Boiler and Pressure Vessel Code. Vessels pressure vessel is not labeled with any ASME inspection insignia. Remove from vessel within two weeks if proof of ASME certification can not be provided to the MI.
46 CFR 182.330
46 CFR 54.01-2 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2024
Resolution: MI received photos of air receiver removed from vessel. All sat.
Navigation › Piloting/Steering › Marine Charts
Issued 29 September 2011
Resolved
Provide approved Navigation Charts.
Due 29 October 2011
Resolved 14 October 2011
Resolution: Corrected.
Fire Fighting › Fire Pumps › Capacity
Issued 27 September 2010
Resolved
Have installed fire pump discharge pressure reach 60psi or renew fire pump with one that will reach 60psi at the outlet. To be completed to the satisfaction of attending Coast Guard inspector by completion of next dry-dock.
Action required: 705 - Other - as specified
Due 28 April 2012
Resolved 22 February 2011
Resolution: Witnessed satisfactory operation of fire pump at 60psi.
Documentation › Certificates/Documents › Stability Letter
Issued 6 July 2008
Resolved
Stability Letter is for Protected Waters only - vessel's operating area was designated Partially Protected by Sector Corpus Christi CID Memo 06-07. Vessel granted a 60 day extention for Stability Letter based on GHS 11.0 calculations by [name withheld] & Associates showing immersion mark 5 inches above the waterline for 128 Total Persons at 185 lbs each. Must complete new/Partially Protected SST.
Due 8 September 2008
Resolved 8 September 2008
Resolution: SST was re-done for Partially Protected Waters & new Stability Letter routed for OCMI signature.
Documentation › Markings/Placards › Official Number (US)
Issued 6 July 2008
Resolved
Permanently affix official number per documentation letter.
Due 18 August 2008
Resolved 18 August 2008
Electrical › Electrical Distribution System (service) › Conductor
Issued 6 July 2008
Resolved
Electrical wiring for special effects needs to be in approved supports.
Due 7 August 2008
Resolved 18 August 2008
Documentation › Markings/Placards › Capacity Marking
Issued 6 July 2008
Resolved
Label upper decks with maximum capacity; 12 forward, 18 aft.
Due 7 July 2008
Resolved 8 July 2008
Documentation › Markings/Placards › Lifejacket Placard
Issued 6 July 2008
Resolved
Post donning instructions for FPDs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2008
Resolved 8 July 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 July 2008
Resolved
[name withheld] stowage locations with size and number of PFDs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2008
Resolved 8 July 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 6 July 2008
Resolved
Provide a copy of fixed firefighting system service report to USCG Marine Inspector.
Due 7 August 2008
Resolved 18 August 2008
Electrical › Electrical Distribution System (service) › Switchboard
Issued 6 July 2008
Resolved
Label switchboard; switches for GPS & depth sounder.
Due 7 August 2008
Resolved 18 August 2008
Lifesaving › Lifebuoys › Immediately Available
Issued 6 July 2008
Resolved
Place lifebuoy on main deck to be accessible to deckhands.
Due 7 August 2008
Resolved 18 August 2008
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 6 July 2008
Resolved
Provide proof that deckhands are enrolled in a DOT approved drug testing program.
Due 7 August 2008
Resolved 18 August 2008
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 6 July 2008
Resolved
Log man-overboard, abandon ship, fire & flooding drills and training.
Due 7 August 2008
Resolved 18 August 2008
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 6 July 2008
Resolved
Place navigation rules onboard vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2008
Resolved 8 July 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 July 2008
Resolved
Place USCG approved 1st aid kit onboard vessel.
Due 7 August 2008
Resolved 18 August 2008