MAURY USCG vessel records Sign in
← All vessels

DOLPHIN II

DOLPHIN II is a 2006 freight ship. The Coast Guard has recorded 24 inspections since 2007, most recently in September 2019, along with 6 deficiencies and 4 operational controls.

Records from 2007 to 2019. Most recent: inspection, 19 September 2019.

Built
2006
Last inspected
19 September 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9318125 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
873314
Flag
PANAMA
—
Maury page id
psix-873314

Inspections, by type

…with no type recorded7
Years with a record 12 calendar years (2007–2019)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it54309 - Convention (Subpart B), Gross Ton
34011 - Convention (Subpart B), Net Ton
65848 - Dead Weight, Ton
86588 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

19 September 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6810070
7 June 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6698703
6 April 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6386062
22 January 2018 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6341557
1 November 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6298753
19 August 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6245341
19 August 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6245432
16 August 2017 ISPS II Exam · PII Safety Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6242183
9 June 2017 PII Safety Exam · Deficiency Check · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6166430
18 July 2016 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5945051
11 January 2016 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5795451
29 November 2015 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5770840
13 September 2015 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5721401
29 May 2014 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4868320
9 July 2012 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4370716
15 August 2011 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4116545
2 January 2011 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3919017
13 October 2010 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3869247
5 May 2009 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3467498
17 April 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3186225
31 October 2007 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3091770
5 September 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3049907
24 February 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2876970
22 February 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2876138

Deficiency record · 6

Engineering › Fuel Oil Service System › Filter
Issued 9 June 2017 Resolved
1420-Means shall be provided to control leaks of flammable liquids. PSCO observed excessive fuel oil in the purifier room. See narrative for details. - 74SOLAS(2014 cons) II-2/4.1
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2017
Resolved 10 June 2017
Resolution: MSU Savannah received class report from BV stating that gaskets were replaced on the duplex filter and was tested satisfactorily with no leaks observed. New lagging was also installed to replace the oil soaked lagging.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 9 June 2017 Resolved
0715-A fire detection system shall comply with the FSS Code. Any required fire detection system shall be capable of immediate operation at all times. PSCO discovered several deficiencies in regards to the vessel's fire detection system. See narrative for details. - 74 SOLAS (2014 cons) II-2/7.2.2 and FSS Code 8.2.5.1.1
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 17 August 2017
Resolution: Verified fixed fire detection system was immediate operation and verified heat dectors in galley was working.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 9 June 2017 Resolved
2250-The safety mgmt system shall be maintained IAW the ISM Code. The Company should establish procedures to ensure the ship is maintained in conformity with rules and regulations. As evidenced in defs #2 above, the PSCO believes the crew is not maintaining the vessel's fire detection system as required - 74 SOLAS (2014 Cons) IX/5, ISM CODE Part A/10
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 17 August 2017
Resolution: Verified vessel has testing and maintainance procedures and is following them.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 29 November 2015 Resolved
0725-The arrangements for the ready availability of water supply shall be with a periodically unattended machinery space or when only one person is required on watch, there shall be immediate water delivery from the fire main system at a suitable pressure. PSCO found the supply to the hyper mist system in the secured position. The Chief eng ..See Form B. SOLAS (Cons Ed 09) II-2 Reg 10.2.1.2.2.2 1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2015
Resolved 29 November 2015
Resolution: MSU Savannah recieved a report from the Classification Society clearing the deficiency.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (air start)
Issued 29 November 2015 Resolved
1410- Measures shall be taken to the satisfaction of the administration to ensure that the equipment is functioning in a reliable manner. While transiting inbound to Garden City Terminal at 0400 on 29 Nov 2015 the main engines forward starting cam disk cracked and subsequently sheered the pin rendering the forward start air distributer inoperable, ...See Form B. SOLAS (Cons Ed 09) II-1 Reg 46.2 17
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2015
Resolved 29 November 2015
Resolution: MSU Savannah recieved a report from the Classification Society clearing the deficiency.
Engineering › Fuel Oil Service System › Tank
Issued 29 November 2015 Resolved
0799- Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, setting or daily service tank having a capacity of 500L and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occu ...See Form B. SOLAS (Cons Ed 09) II-2 Reg 4.2.2.3.4 17AC
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2015
Resolved 29 November 2015
Resolution: MSU Savannah recieved a report from the Classification Society clearing the deficiency.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.