← All vessels
LONDON STAR
LONDON STAR is a 2006 tank ship. The Coast Guard has recorded 33 inspections since 2007, most recently in October 2024, along with 12 deficiencies and 8 operational controls.
Records from 2007 to 2024. Most recent: inspection, 19 October 2024.
- Built
- 2006
- Last inspected
- 19 October 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9330343 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8KN4
873343
Flag
LIBERIA
—
Maury page id
psix-873343
Inspections, by type
…with no type recorded9
Years with a record
13 calendar years (2007–2024)
The 33 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it41966 - Convention (Subpart B), Gross Ton
22047 - Convention (Subpart B), Net Ton
73869 - Dead Weight, Metric Ton
88869 - Displacement, Metric Ton
22047 - Convention (Subpart B), Net Ton
73869 - Dead Weight, Metric Ton
88869 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 33
19 October 2024
PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8018684
1 October 2023
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7801510
24 September 2023
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7795731
19 July 2023
PSC B · COC-TVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7742971
18 July 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7744322
16 July 2023
COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7743499
28 May 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7698344
10 May 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7685598
10 May 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7749471
25 November 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7599558
15 July 2022
PSC B · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7507549
6 April 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7169875
28 March 2021
PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7161256
26 June 2020
COC-TVE Annual · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6981782
12 December 2019
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6872349
3 July 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6734960
31 March 2019
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6644387
31 October 2018
COE-Administrative
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6571904
19 September 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6544403
20 April 2018
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6388380
10 April 2018
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6388715
23 February 2018
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6360582
21 March 2017
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6107766
19 May 2016
PII Safety Exam · ISPS III Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5878554
10 May 2016
ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5871099
8 May 2016
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5871866
26 October 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3877988
27 July 2009
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3547859
10 April 2009
MARPOL Annex VI Survey · MARPOL Annex I Examination · ISPS III Exam · Ballast Water Examination · COC-TVE Renew · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3448287
1 February 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3403342
5 September 2008
MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · COC-TVE Annual · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3309400
28 February 2007
MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2878396
19 February 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2874077
Deficiency record · 12
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 July 2022
Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers, unless the administration is satisfied that such equipment is of a type which will not ignite the mixture concerned. PSCO observered explosion proof fixture with cracked lens in cargo pump room.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 July 2022
Resolved
The venting system shall be provided with devices to prevent the passage of flame into the cargo tanks. PSCO observed missing flame screen on vacuum valve on number one port cargo tank.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 March 2021
Resolved
No electrical equipment shall be installed in any space where flammable mixtrues are liable to collect, unless the Administration is satisfied that such equipment is: appropriately certified for safe usage in the vapours or gases likley to be encountered. PSCO observed one junction box with improperly sealed cable gland, and one light missing a grounding cable in cargo pump room.
SOLAS 74(a), 2004 cons., II-1/45.10.4
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 28 March 2021
Resolved
Automatic shutdown of the inert gas blowers and gas regulating valve shall be arranged on predetermined limits being reached in respect of paragraph 2.4.3.1.2 (low water supply to scrubber). PSCO observed low water pressure to scrubber failed to shutdown IG system.
SOLAS 74(a), 2014 cons., II-2/4.5.5.1.3
IMO Res. MSC.(98)73 (FSS Code) Ch.15/2.3.1.5.1
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 23 February 2018
Resolved
1400- THE MACHINERY, BOIILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM AND DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO... OTHER HAZARDS. THE VESSEL EXPERIENCED AN EQUIPMENT FAILURE WHILE TRANSITING THE NAVIGABLE WATERS OF THE UNITED STATES WHICH ADVERSELY AFFECTED ITS MANEUVERABILITY AND POSED A HAZARD TO VESSELS AND INFRASTRUCTURE ALONG THE HOUSTON SHIP CHANNEL. 74 SOLAS (04) II-1/26. 17AC.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 23 February 2018
Resolved
THE COMPANY SHOULD IDENTIFY EQUIPMENT AND TECHNICAL SYSTEMS THE SUDDEN OPERATIONAL FAILURE OF WHICH MAY RESULT IN HAZARDOUS SITUATIONS. THE SAFETY MANAGEMENT SYSTEM SHOULD PROVIDE FOR SPECIFIC MEASURES AIMED AT PROMOTING THE RELIABILITY OF SUCH EQUIPMENT OR SYSTEMS. THE VESSEL EXPERIENCED AN EQUIPMENT FAILURE WHILE TRANSITING THE NAVIGABLE WATERS OF THE UNITED STATES WHICH ADVERSELY IMPACTED ITS FITNESS AND CAPABILITY TO SAFELY MANEUVER THE HOUSTON SHIP CHANNEL. 74 SOLAS (14) IX/3.1 REF. ISM A/9 & 10.3.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 19 May 2016
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Fire Fighting › Ventilation Systems › Fans
Issued 10 May 2016
Resolved
Machinery spaces of category A shall be adequately ventilated so as to ensure that in all weather conditions including heavy weather, an adequate supply of air is maintained to the spaces for the safety and comfort of personnel and the operation of the machinery. During the operation of the inert gas system, a hazardous atmosphere was detected, posing a danger to the crew. 74 SOLAS(09)II-1/35
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 10 May 2016
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The vessel's crew has secured heavy fuel oil quick closing valves in the open position rendering fire protective service inoperable. 74SOLAS(09) IX/3.1 ISM Code Part A 10.1
Navigation › Piloting/Steering › Gyro Compass
Issued 26 October 2010
Resolved
The gyro compass was reported not operational.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 10 April 2009
Resolved
The pressure guages for the cargo manifold in the Cargo Control Room are not working as designed. The Coast Guard Inspector verified the independent pressure guage on the actual cargo manifold was working.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 10 April 2009
Resolved
The vessel Oil Discharge Monitoring Equipment was not working at the time of the examination.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.