MAURY USCG vessel records Sign in
← All vessels

CAP BEATRICE

CAP BEATRICE is a 2007 freight ship. The Coast Guard has recorded 14 inspections since 2007, most recently in December 2021, along with 5 deficiencies and 2 operational controls.

Records from 2007 to 2021. Most recent: inspection, 8 December 2021.

Built
2007
Last inspected
8 December 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9330537 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
873375
Flag
LIBERIA
—
Maury page id
psix-873375

Inspections, by type

…with no type recorded6
Years with a record 5 calendar years (2007–2021)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28616 - Simplified, Gross Ton
28616 - Convention (Subpart B), Gross Ton
14769 - Simplified, Net Ton
14769 - Convention (Subpart B), Net Ton
39360 - Dead Weight, Ton
51309 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

8 December 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7365955
1 October 2010 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3860999
2 March 2010 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3688283
22 December 2009 ISPS I Exam · Deficiency Check · PI Safety Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3654063
21 December 2009 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3653379
21 December 2009 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3653531
15 September 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3325519
29 April 2008 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3195092
25 April 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3192066
31 March 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3174776
15 June 2007 ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2962830
25 February 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2877169
25 February 2007 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2877269
23 February 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2876653

Deficiency record · 5

Engineering › Steam Boiler (auxiliary/waste heat) › Handhole
Issued 1 October 2010 Resolved
1499-Machinery shall be suitable for purpose intended. During outbound transit, the engineering watch discovered composite boiler was leaking water and steam from a hand hole/inspection cover due to a failed gasket. Crew to repair and pressure test prior to departure. SOLAS 2004 (cons ed) II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Due 2 October 2010
Resolved 2 October 2010
Resolution: Sector Delaware Bay received a statement from the Chief Engineer attesting to the proper repair and testing of the boiler.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 22 December 2009 Resolved
1030- Steering gear alarm-A low-level alarm for each hydraulic fluid reservoir to give the earliest practical indication of hydraulic fluid leakage. Audio and visual alarms shall be given on the nav. bridge and in the machinery space. Low level alarm for #2 hydraulic reservoir sounded on nav. bridge, however no audio or visual alarm was given in the machinery space. SOLAS 2004 CH II-1/29.12.2
Action required: 705 - Other - as specified
Due 22 January 2010
Resolved 2 March 2010
Resolution: Witnessed proper operation of low level alarm for #2 hydraulic reservoir on the navigation bridge and the machinery space.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 22 December 2009 Resolved
0110- CARGO SHIP SAFETY EQUIPMENT-The certificates issued under regulations 12 and 13 shall be readily available on board at all times. The SOLAS Safety Equipment certificate was provided in only a "copy" form. SOLAS 2004 CH 1/16
Action required: 705 - Other - as specified
Due 22 January 2010
Resolved 2 March 2010
Resolution: Vessel provided original SOLAS Safety Equipment certificate.
Fire Fighting › Nozzles › Number
Issued 31 March 2008 Resolved
Three fire stations on main deck were missing fire nozzles. Replace missing nozzles to the satisfaction of attending classification society surveyor.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 29 April 2008
Resolution: Rcvd class report via email, cleared def.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 31 March 2008 Resolved
Voyage Data Recorder is not downloading to the VDR hard drive. Latest test report indicated failure of VDR to communicate with hard drive. Class surveyor to diagnose problem and ensure proper functioning of VDR
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 April 2008
Resolution: Received tech report that VDR is know working properly.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.