MAURY USCG vessel records Sign in
← All vessels

MONTE ROSA

MONTE ROSA is a 2006 tank ship. The Coast Guard has recorded 33 inspections since 2007, most recently in February 2026, along with 11 deficiencies and 5 operational controls.

Records from 2007 to 2026. Most recent: inspection, 14 February 2026.

Built
2006
Last inspected
14 February 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9301952 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
873411
Flag
MARSHALL ISLANDS
—
Maury page id
psix-873411

Inspections, by type

…with no type recorded7
Years with a record 17 calendar years (2007–2026)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it42403 - Convention (Subpart B), Gross Ton
21777 - Convention (Subpart B), Net Ton
88871 - Displacement, Metric Ton
74933 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 33

14 February 2026 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8310623
12 February 2026 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8310057
30 November 2025 PSC C · COC-TVE Renew
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8273304
21 October 2025 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8256412
3 January 2025 PSC B · COC-TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8054256
29 July 2024 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7965906
24 July 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7966091
24 November 2023 PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7828131
9 November 2022 PSC B · COC-TVE Annual
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7589371
9 November 2021 COC-TVE Renew · PSC B · Ballast Water Examination · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7347825
22 April 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7181770
25 September 2020 PSC B · COC-TVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7062038
11 September 2019 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6805586
19 July 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6755295
31 July 2018 ISPS III Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6496369
27 November 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6313502
24 August 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6250541
15 August 2017 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6237570
12 May 2017 In-Service Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6144174
22 April 2017 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6133973
14 August 2016 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5973408
10 August 2015 COC-TVE Renew · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5209136
27 July 2012 Deficiency Check
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4392508
1 July 2012 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4346464
15 February 2012 COE-Dockside
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4244672
1 July 2011 COE-Dockside · ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4064294
23 October 2010 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3876239
13 March 2008 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3164110
24 October 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3086159
11 October 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3077937
14 September 2007 Administrative Inspection · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3057714
28 February 2007 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2879236
27 February 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2878971

Deficiency record · 11

Accommodation/Occupational Safety › Ventilation › General
Issued 12 May 2017 Resolved
0900: The condition of the ship and its equipment shall be mantained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO witnessed inoperable fixed gas sampling device which services the ballast water tanks and cargo pump room. 74 SOLAS(14)I/11
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2017
Resolved 12 May 2017
Resolution: Received class report from ABS attesting to the proper repairs.
Lifesaving › Launching Appliances › Winch
Issued 10 August 2015 Resolved
0610; A lifeboat launching appliance shall be capable or recovering the lifeboat with its crew. Each rescue boat launching appliance shall be fitted with a motor capable of raising the rescue boat from the water. Crew was unable to recover the lifeboat and rescue boat as designed, 74 SOLAS (14) III/34, LSA 6.1, 17AC.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2015
Resolved 11 August 2015
Resolution: Corrected to the satisfaction of the attending Classification Surveyor.
Lifesaving › Lifeboat › Hatches
Issued 10 August 2015 Resolved
0610; Every totally enclosed lifeboat shall be provided with a rigid water tight enclosure. Aft hatches on boat starboard and port survival crafts have cracks next to the aluminum hatch frame allowing water intrusion, 74 SOLAS (14) III/34, LSA 4.6, 17AC.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2015
Resolved 11 August 2015
Resolution: Corrected to the satisfaction of the attending Classification Surveyor.
Deck/Cargo › Ballast › Piping
Issued 10 August 2015 Resolved
1820; The machinery and associated piping shall be of a design and construction adequate fro the service for which they are intended. A soft patch was found in the cargo pump room on ballast pump #2 vacuum piping. In addition the high temperature sensor probe on #1 COP was held in place by glue and tape, 74 SOLAS (14) II-1/26.1, 17AC.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2015
Resolved 11 August 2015
Resolution: Corrected to the satisfaction of the attending Classification Surveyor.
Documentation › Certificates/Documents › IOPP Certificate
Issued 10 August 2015 Resolved
0150; A IOPP Certificate shall be issued after survey in accordance with the provisions of MARPOL Annex 1 Reg. 6 and shall be issued as appropriate. The identified tanks in section 3.1 on form b of the IOPP are not listed clearly along with their capacities, 73/78 MARPOL 1/7, 40AC.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 August 2015
Resolution: Corrected to the satisfaction of the attending Classification Surveyor.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 10 August 2015 Resolved
0695; The training manual shall contain instruction and information on the life saving appliance s provide don the ship. Section 11 of the life saving training manual is not completed and section 7 of the fire fighting training manual is not complete, 74 SOLAS (14) III 35.3 / 74 SOLAS (14) II-2/2.3.3, 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: Discussed with the [name withheld] representative, [name withheld], Chief Engineer and Third Mate.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 10 August 2015 Resolved
1835; The last 1.0 meter of Vapor piping must be painted red/yellow/red. three of the four vapor control lines at the manifold have no red paint. 46 CFR 39.20-1(d)(i), 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: Discussed with the [name withheld] representative, [name withheld], Chief Engineer and Third Mate.
Electrical › Lighting (service) › Grounding Conductor
Issued 10 August 2015 Resolved
0950; All tank vessel are subject t the regulation contained in subchapter J. Two deck lights forward of the house located close to the pump room were missing grounding wires, 46 CFR 31.35-1, 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: Discussed with the [name withheld] representative, [name withheld], Chief Engineer, ships Electrician replaced the wires.
Operations/Management › Pollution › Control of Garbage
Issued 10 August 2015 Resolved
2120; Disposal in the sea of synthetic ropes is prohibited. Nylon ropes and plastic covers on deck were fraying and deteriorating with pieces going overboard into the sea, 73/78 MARPOL V/5.2(a)(i), 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: Discussed with the [name withheld] representative, [name withheld] and Chief Engineer.
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 1 July 2012 Resolved
FLUE GAS SCRUBBER SHALL BE FITTED WHICH WILL EFFECTIVELY COLL THE VOLUME OF GAS. THE COOLING WATER ARRANGEMENTS SHALL BE SUCH THAT AN ADEQUATE SUPPLY OF WATER WILL ALWAYS BE AVAILABLE. VESSEL SALT WATER SUPPY TO SCRUBBER AT SPRAY WATER INLET FLANGE HOLED (PIN HOLES 3) 74 SOLAS(09 CONS.) II-2 REG 4/5.5.3.2, FSS CODE CHAP 15/ 2.2.2.1, 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 July 2012
Resolution: Class attended vessel in Panama and cleard outstanding defs. Class report submitted.
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 1 July 2012 Resolved
SPECIAL CONSIDERATION SHALL BE GIVEN TO THE DESIGN AND LOCATION OF SCRUBBER WITH RELEVANT PIPING IN ORDER TO PREVENT FLUE GAS LEAKAGES. VESSEL FLUE GAS INLET DUCT TO SCRUBBER FLANGE HOLED. 74 SOLAS(09 CONS) II-2 REG 4/5.5.3.2, FSS CODE CHAPTER 15/2.3.1.2.1, 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 July 2012
Resolution: Class attended vessel in Panama and cleard outstanding defs. Class report submitted.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.