← All vessels
ST INNOCENT
Freight Ship · General Dry Cargo Ship class · Built 1960s · USCG Arctic District (CGD-A) · Other hulls named ST INNOCENT
ST INNOCENT is a 1965 freight ship. The Coast Guard has recorded 12 inspections since 1987, most recently in July 2012, along with 37 deficiencies and 4 operational controls.
Records from 1987 to 2012. Most recent: inspection, 11 July 2012.
- Built
- 1965
- Last inspected
- 11 July 2012
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 37 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
…with no type recorded10
Years with a record
7 calendar years (1987–2012)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
73 - Regulatory (Subpart C or D), Net Ton
73 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
11 July 2012
In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 4379076
2 March 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 728836
12 January 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 187024
30 November 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 422352
15 October 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 728835
3 October 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 104842
12 February 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 400534
13 June 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 392491
18 January 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 387501
18 January 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 392080
5 December 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 385612
13 July 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016680
Deficiency record · 37
Unknown
Issued 30 November 1998
Resolved
PRIOR TO LOADING, FAX SURVEYOR REPORT ADDRESSING ABOVE ITEMS TO USCG FOR COAST GUARD INSPECTION.
Unknown
Issued 30 November 1998
Resolved
PRIOR TO LOADING, HAVE SURVEYOR ADDRESS WELD REPAIRS, OPERATIONAL READINESSOF MACHINERY, AND CREW READINESS FOR THE ABANDON SHIP AND FIRE DRILL.
Engineering
Issued 30 November 1998
Resolved
HAVE FLAG ADMINISTRATION ADDRESS VESSEL ENGINE ROOM AS MANNED OR UNMANNED.
Documentation
Issued 30 November 1998
Resolved
PROVE ALL CREW HAVE HAD MEDICAL EXAMINATIONS.
Fire Fighting
Issued 30 November 1998
Resolved
MOUNT FIRE CONTROL PLAN IN AREA OUTSIDE OF PILOTHOUSE. CCSSC 3.13
Engineering
Issued 30 November 1998
Resolved
PROVIDE MEANS TO SECURE POWER VENTILATION TO FOR THE ENGINE ROOM FROM OUTSIDE THE SPACE.
Navigation
Issued 30 November 1998
Resolved
PROCE PROPER OPERARION OF THE RUDDER ANGLE INDICATOR.
Navigation
Issued 30 November 1998
Resolved
PROVE OPERATION OF EMERGENCY STEERING. CCSSC 2.38
Fire Fighting
Issued 30 November 1998
Resolved
PERFORM SATISFACTORY FIRE AND ABANDON SHIP DRILL TO THE SATISFACTION OF THEU. S. COAST GUARD INSPECTOR. CCSSC 4.17
Construction/Loadline
Issued 30 November 1998
Resolved
PRIOR TO LOADING, REMOVE ALL BUCKETS OF OILY WASTE AND PUMP THE OILY WATER FROM THE BILGE TO A SHORE FACILITY AND FAX RECEIPT TO COAST GUARD.
Navigation
Issued 12 February 1997
Resolved
Update charts IAW current notice to mariners.
Lifesaving
Issued 12 February 1997
Resolved
provide 3 additional smoke signals on board
Fire Fighting
Issued 12 February 1997
Resolved
Prove proper operation of ships fire pumps.
Navigation
Issued 12 February 1997
Resolved
Provide current light list and coast pilot on board
Navigation
Issued 12 February 1997
Resolved
repair light for magnetic compass
Electrical
Issued 12 February 1997
Resolved
Provide covers for all exposed lights on board.
Construction/Loadline
Issued 12 February 1997
Resolved
Repair dogs and gaskets on all watertight doors.
Lifesaving
Issued 12 February 1997
Resolved
Provide 2 waterlights for two liferings and retro-reflective tape on all liferings.
Engineering
Issued 12 February 1997
Resolved
Repair flame screens on fuel vents._x001C_
Construction/Loadline
Issued 12 February 1997
Resolved
Paint draft marks in contrasting color to hull fwd and aft.
Accommodation/Occupational Safety
Issued 12 February 1997
Resolved
Place lock and chain on marine sanitation device overboard discharge valve.
Electrical
Issued 12 February 1997
Resolved
Properly dead-end unused cables/wires in engine room, galley, and dining room.
Navigation
Issued 12 February 1997
Resolved
Demonstrate proper operation of navigation lights and proper location.
Documentation
Issued 12 February 1997
Resolved
Provide current crew list on board.
Electrical
Issued 12 February 1997
Resolved
Provide light bulb covers in engine room.
Electrical
Issued 12 February 1997
Resolved
Prove proper operation of ships generator.
Engineering
Issued 12 February 1997
Resolved
Prove proper operation of main engines (both engines undergoing repairs during inspection).
Construction/Loadline
Issued 12 February 1997
Resolved
prove proper operation of fixed bilge system.
Documentation
Issued 12 February 1997
Resolved
Provide up to date medical certificates for all crewmembers on board.
Lifesaving
Issued 5 December 1995
Resolved
Surveyor's report on condition of hull bottom-diver must report on results of underwater inspection._x001C_ _x001C_ _x001C_
Navigation
Issued 5 December 1995
Resolved
Nav lights; side, stern, masthead must be in running order. Install marineapproved lightbulbs._x001C_ _x001C_ _x001C_
Engineering
Issued 5 December 1995
Resolved
Fuel fill must have threaded closure._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 5 December 1995
Resolved
Fuel vent needs flame screen._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 5 December 1995
Resolved
Wasted and cut forward bulkhead to be restored-no breaches._x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 5 December 1995
Resolved
Steering and emergency steering to be tested._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 5 December 1995
Resolved
Surveyor's report on ship's frame condition, fwd and aft._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 5 December 1995
Resolved
Surveyor's report on condition and capacity of fuel tanks and fuel deliverysystem._x001C_ _x001C_ _x001C_
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.