ST INNOCENT

ST INNOCENT is a 1965 freight ship. The Coast Guard has recorded 12 inspections since 1987, most recently in July 2012, along with 37 deficiencies and 4 operational controls.

Records from 1987 to 2012. Most recent: inspection, 11 July 2012.

Built
1965
Last inspected
11 July 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
HAITI
—
Maury page id
psix-87374

Inspections, by type

…with no type recorded10
Years with a record 7 calendar years (1987–2012)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
73 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 12

11 July 2012 In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 4379076
2 March 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 728836
12 January 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 187024
30 November 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 422352
15 October 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 728835
3 October 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 104842
12 February 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 400534
13 June 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 392491
18 January 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 387501
18 January 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 392080
5 December 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 385612
13 July 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016680

Deficiency record · 37

Unknown
Issued 30 November 1998 Resolved
PRIOR TO LOADING, FAX SURVEYOR REPORT ADDRESSING ABOVE ITEMS TO USCG FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Unknown
Issued 30 November 1998 Resolved
PRIOR TO LOADING, HAVE SURVEYOR ADDRESS WELD REPAIRS, OPERATIONAL READINESSOF MACHINERY, AND CREW READINESS FOR THE ABANDON SHIP AND FIRE DRILL.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Engineering
Issued 30 November 1998 Resolved
HAVE FLAG ADMINISTRATION ADDRESS VESSEL ENGINE ROOM AS MANNED OR UNMANNED.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Documentation
Issued 30 November 1998 Resolved
PROVE ALL CREW HAVE HAD MEDICAL EXAMINATIONS.
Condition: Unknown
Due 2 December 1998
Resolved 2 December 1998
Fire Fighting
Issued 30 November 1998 Resolved
MOUNT FIRE CONTROL PLAN IN AREA OUTSIDE OF PILOTHOUSE. CCSSC 3.13
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Engineering
Issued 30 November 1998 Resolved
PROVIDE MEANS TO SECURE POWER VENTILATION TO FOR THE ENGINE ROOM FROM OUTSIDE THE SPACE.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Navigation
Issued 30 November 1998 Resolved
PROCE PROPER OPERARION OF THE RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 2 December 1998
Resolved 2 December 1998
Navigation
Issued 30 November 1998 Resolved
PROVE OPERATION OF EMERGENCY STEERING. CCSSC 2.38
Condition: Unknown
Due 2 December 1998
Resolved 2 December 1998
Fire Fighting
Issued 30 November 1998 Resolved
PERFORM SATISFACTORY FIRE AND ABANDON SHIP DRILL TO THE SATISFACTION OF THEU. S. COAST GUARD INSPECTOR. CCSSC 4.17
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Construction/Loadline
Issued 30 November 1998 Resolved
PRIOR TO LOADING, REMOVE ALL BUCKETS OF OILY WASTE AND PUMP THE OILY WATER FROM THE BILGE TO A SHORE FACILITY AND FAX RECEIPT TO COAST GUARD.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Navigation
Issued 12 February 1997 Resolved
Update charts IAW current notice to mariners.
Condition: Unknown
Due 24 April 1997
Resolved 25 April 1997
Lifesaving
Issued 12 February 1997 Resolved
provide 3 additional smoke signals on board
Condition: Unknown
Due 22 April 1997
Resolved 24 April 1997
Fire Fighting
Issued 12 February 1997 Resolved
Prove proper operation of ships fire pumps.
Condition: Unknown
Due 24 April 1997
Resolved 25 April 1997
Navigation
Issued 12 February 1997 Resolved
Provide current light list and coast pilot on board
Condition: Unknown
Due 24 April 1997
Resolved 25 April 1997
Navigation
Issued 12 February 1997 Resolved
repair light for magnetic compass
Condition: Unknown
Due 24 April 1997
Resolved 25 April 1997
Electrical
Issued 12 February 1997 Resolved
Provide covers for all exposed lights on board.
Condition: Unknown
Due 22 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 12 February 1997 Resolved
Repair dogs and gaskets on all watertight doors.
Condition: Unknown
Due 22 April 1997
Resolved 24 April 1997
Lifesaving
Issued 12 February 1997 Resolved
Provide 2 waterlights for two liferings and retro-reflective tape on all liferings.
Condition: Unknown
Due 22 April 1997
Resolved 24 April 1997
Engineering
Issued 12 February 1997 Resolved
Repair flame screens on fuel vents._x001C_
Condition: Unknown
Due 22 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 12 February 1997 Resolved
Paint draft marks in contrasting color to hull fwd and aft.
Condition: Unknown
Due 24 April 1997
Resolved 25 April 1997
Accommodation/Occupational Safety
Issued 12 February 1997 Resolved
Place lock and chain on marine sanitation device overboard discharge valve.
Condition: Unknown
Due 24 April 1997
Resolved 25 April 1997
Electrical
Issued 12 February 1997 Resolved
Properly dead-end unused cables/wires in engine room, galley, and dining room.
Condition: Unknown
Due 22 April 1997
Resolved 24 April 1997
Navigation
Issued 12 February 1997 Resolved
Demonstrate proper operation of navigation lights and proper location.
Condition: Unknown
Due 24 April 1997
Resolved 25 April 1997
Documentation
Issued 12 February 1997 Resolved
Provide current crew list on board.
Condition: Unknown
Due 24 April 1997
Resolved 25 April 1997
Electrical
Issued 12 February 1997 Resolved
Provide light bulb covers in engine room.
Condition: Unknown
Due 22 April 1997
Resolved 24 April 1997
Electrical
Issued 12 February 1997 Resolved
Prove proper operation of ships generator.
Condition: Unknown
Due 24 April 1997
Resolved 25 April 1997
Engineering
Issued 12 February 1997 Resolved
Prove proper operation of main engines (both engines undergoing repairs during inspection).
Condition: Unknown
Due 22 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 12 February 1997 Resolved
prove proper operation of fixed bilge system.
Condition: Unknown
Due 1 May 1997
Resolved 6 May 1997
Documentation
Issued 12 February 1997 Resolved
Provide up to date medical certificates for all crewmembers on board.
Condition: Unknown
Due 22 April 1997
Resolved 24 April 1997
Lifesaving
Issued 5 December 1995 Resolved
Surveyor's report on condition of hull bottom-diver must report on results of underwater inspection._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Navigation
Issued 5 December 1995 Resolved
Nav lights; side, stern, masthead must be in running order. Install marineapproved lightbulbs._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Engineering
Issued 5 December 1995 Resolved
Fuel fill must have threaded closure._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Engineering
Issued 5 December 1995 Resolved
Fuel vent needs flame screen._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Lifesaving
Issued 5 December 1995 Resolved
Wasted and cut forward bulkhead to be restored-no breaches._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 February 1996
Resolved 29 July 1996
Navigation
Issued 5 December 1995 Resolved
Steering and emergency steering to be tested._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Lifesaving
Issued 5 December 1995 Resolved
Surveyor's report on ship's frame condition, fwd and aft._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Engineering
Issued 5 December 1995 Resolved
Surveyor's report on condition and capacity of fuel tanks and fuel deliverysystem._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.