Records from 2006 to 2014. Most recent: inspection, 1 October 2014.
Documentation record
Registered dimensions (L × B × D)61.2 ft × 21.3 ft × 7.2 ft
Registered tonnagegross 62 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALLEN MARINE INC · SITKA, AK, UNITED STATES · built 2007
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBROOKS CAMP, AK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 July 2026 · expires 31 July 2027
Service, as the file records itUnclassified
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it62 - Simplified, Gross Ton
50 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 10
1 October 2014
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5006500
22 June 2012
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4352259
1 May 2012
Drydock Extension
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4336146
8 September 2010
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3899533
30 March 2010
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3705885
22 July 2009
Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3543828
29 December 2008
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3386107
7 October 2008
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3340227
25 September 2008
Type not recorded
No type recorded · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3332673
21 August 2006
Deadweight Survey · Plan Review "T" Boat · Construction Oversight · COI Inspection · Inclining Experiment
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 2878154
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 22 June 2012
Resolved
Provide proof of random drug testing progrgam enrollment for the crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2012
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Inflatable Liferafts › Servicing
Issued 22 June 2012
Resolved
Properly mount serviced liferaft
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2012
Resolution: Provided photographs of the mounted liferaft with the 2013 decal
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 22 June 2012
Resolved
Provide proof of servicing of portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2012
Resolution: New extinguishers purchased.
Construction/Loadline › Hull › Hull Plating
Issued 1 May 2012
Resolved
Vessel shall undergo a hull and internal structural examination by 31 January 2015 per Hull Interval Extension Letter dated 6 JUN 12.
Due 31 January 2015
Resolved 12 February 2015
Resolution: Vessel is no longer inspected.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 22 July 2009
Resolved
Properly stencil life jackets with vessels name IAW 46CFR 185.604(b).
Action required: 705 - Other - as specified
Due 22 August 2009
Resolved 22 August 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 July 2009
Resolved
Properly separate child life jackets from adults IAW 46CFR 180.78(a)(5).
Action required: 705 - Other - as specified
Due 22 August 2009
Resolved 22 August 2009
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 22 July 2009
Resolved
Install simple instructions for the fixed gas fire ext. system near pull box IAW 46CFR185.612(a).
Action required: 705 - Other - as specified
Due 22 August 2009
Resolved 22 August 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 December 2008
Resolved
Vessel issued 835 no-sail for vessel missing required 2007 annual inspection.
Action required: 705 - Other - as specified
Resolved 22 July 2009
Operations/Management › Drills/Instruction › Not Conducted
Issued 3 August 2007
Resolved
Conduct drills to the satisfaction of the attending Coast Guard Marine Inspectors at Sector Anchorage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2009