Records from 1991 to 2026. Most recent: inspection, 31 March 2026.
Documentation record
Registered dimensions (L × B × D)93.0 ft × 27.6 ft × 10.6 ft
Registered tonnagegross 127 / net 86
ITC dimensions (L × B × D)92.4 ft × 28.2 ft × 13.0 ft
ITC tonnagegross 224 / net 67
BuilderBARKER BARGE LINES · LOCKPORT, LA, UNITED STATES · built 1965
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCOOS BAY, OR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 May 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it127 - Regulatory (Subpart C or D), Gross Ton
224 - Convention (Subpart B), Gross Ton
86 - Regulatory (Subpart C or D), Net Ton
67 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 39
31 March 2026
Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8338901
13 May 2025
DAPI Audit · COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8134904
21 March 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7883081
13 June 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7714440
27 April 2023
Annual Inspection · DAPI Audit
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7679693
30 March 2022
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7621267
30 September 2021
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7318816
16 September 2021
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7313988
2 August 2021
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7275228
2 August 2021
Type not recorded
No type recorded · Station Yaquina Bay · USCG Northwest District (CGD-NW) · Activity 7275489
6 May 2021
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7213167
12 February 2020
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6907325
16 December 2019
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6874708
25 November 2019
DAPI Audit
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6862494
27 January 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6622061
24 September 2018
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6547505
21 September 2018
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6545673
9 August 2018
Initial Certification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6505079
29 April 2015
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5113504
23 May 2013
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4603977
23 May 2013
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4897602
13 December 2011
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4200350
3 September 2010
Administration
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3841129
5 May 2010
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3731470
15 November 2006
MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2821665
12 October 2005
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2512699
12 October 2005
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2512871
29 September 2004
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2209337
20 August 2004
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2171770
6 November 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1943293
30 May 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1805599
29 May 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1805579
25 August 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1667692
16 June 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 477005
22 May 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 498362
9 April 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 191506
9 April 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 755959
1 January 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 29278
18 August 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 14807
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 September 2021
Resolved
The managing owner or managing operator of a towing vessel, who has selected the Coast Guard inspection option, must make their vessel available for the Coast Guard to conduct the examinations required by this subpart in accordance with the intervals prescribed in
§137.300. The vessel failed to undergo a credit drydock and internal structure exam by the date listed on the COI. The vessel shall be made available for drydock and internal structure exam within 60 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no longer be permitted to operate.
Action required: 705 - Other - as specified
Due 16 November 2021
Resolved 30 September 2021
Resolution: Vessel conducted satisfactory DD/ISE.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 12 February 2020
Resolved
EACH TOWING VESSEL OPERATING IN OCEANS OR COASTWISE SERVICE MUST HAVE A LINE THROWING APPLIANCE APPROVED UNDER APPROVAL SERIES 160.040. VESSEL ONLY HAD ONE PROJECTILE INSTEAD OF 04 PROJECTILES AS REQUIRED BY REGULATION. PROVIDE EVIDENCE OF PURCHASE OF ADDITIONAL LINE THROWING DEVICES TO MEET THE REQUIREMENTS AS PER 46 CFR 141.385.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2020
Resolved 6 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 25 November 2019
Resolved
No marine employer shall engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. Documentation provided by your company and your testing consortium indicates that several employees did not complete DOT pre-employment drug testing.
Provide evidence that all current Marine employees have completed DOT approved pre-employment drug testing.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2020
Resolution: Company provided evidence that all current marine employees have completed DOT approved pre-employment drug testing.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 25 November 2019
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew-members on inspected vessels who occupy a position or preform the duties and functions of a position, required by the vessel's Certificate of Inspection. Documentation indicates that several employees are not enrolled in a DOT random drug testing program.
Provide proof that all current marine employees are enrolled in a DOT random testing program.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2020
Resolution: Complany provided proof that all current marine employees are involved in a DOT approved random chemical testing program.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 24 September 2018
Resolved
Vsl is broadcasting: Invalid IMO #, no static draft information, and no dimension information (AIS Antenna Position ABCD values equals 0).
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 October 2018
Resolved 13 December 2018
Resolution: AIS discrepancy corrected, AIS broadcasting all pertinent information.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 August 2018
Resolved
Audible bilge high water alarm must be present in the operating station. Buzzer on the alarm panel did not operate when tested.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2018
Resolved 7 September 2018
Resolution: Verified audible alarme in wheelhouse.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 August 2018
Resolved
Vessel needs to instal 01 additional all around red light and 01 all around white light to meet COLREG requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2018
Resolved 7 September 2018
Resolution: Verified proper installation of nav. lights.