HORIZON EAGLE

HORIZON EAGLE is a 2007 freight ship. The Coast Guard has recorded 9 inspections since 2007, most recently in February 2010, along with 2 deficiencies — 1 with no resolution recorded —, 1 operational control and 2 casualty investigations between 2007 and 2008.

Records from 2007 to 2010. Most recent: inspection, 7 February 2010.

Built
2007
Last inspected
7 February 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9314997 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDD6039
874368
Flag
UNITED STATES
—
Maury page id
psix-874368

Inspections, by type

…with no type recorded3
Years with a record 3 calendar years (2007–2010)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28927 - Convention (Subpart B), Gross Ton
39276 - Dead Weight, Ton
51309 - Displacement, Ton
15033 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 9

7 February 2010 Underwater Inspection in lieu of Drydock
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3673530
7 February 2010 Underwater Inspection in lieu of Drydock
Physical examination · Commandant (CG-5P-TI) · Activity 3809120
16 November 2008 Damage Survey · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3366930
16 August 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3309611
20 June 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3242520
15 April 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3177073
6 December 2007 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3110236
12 November 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3117227
11 April 2007 MARPOL Annex I Examination · MTSA/ISPS Verification · MARPOL Annex V Examination · Reflagging & Initial Certification
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2899709

Deficiency record · 2

Construction/Loadline › Hull › Girder
Issued 16 November 2008 Resolved
A 19" fracture occurred along the leading edge of a butt weld on the first inboard underdeck girder from the port side shell between frames 72 & 73 (amidships). As the existing weld was being ground down, severe porosity and incomplete penetration with the edge of the girder was noted. Thus, the fracture can be contributed to a poor weld during new construction.
Condition: Improper Installation
Due 16 November 2008
Resolved 16 November 2008
Resolution: The fractured weld was repaired using a double vee configuration. A satisfactory mag particle test was witnessed on the root pass and the final weld repair is considered permanent.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 15 April 2008 No resolution recorded
The company-provided Garbage Management Plan did not contain specific information about the vessel at locations indicated in the plan.
Action required: 705 - Other - as specified
Resolution: Plan modified to include ship-specific details.

Casualty record · 2

12 November 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3117227
16 August 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3309611
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record